Get complete information related to latest Obsolete Motor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Obsolete Motor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Obsolete Motor Tenders.
Tender For corrigendum : upgradation augmentation of shot blasting equipment and shot blasting room including replacement of three motor driven screw lp air compressor for upgradation augmentation of production shop floor (ab and ac bay) at ins eksila - upgradation/ augmentation of shot blasting equipment and shot blasting room including replacement lp air compressor as indicated in part-ii of rfp consists of the following:-, dismantling and degutting of lp air compressors along with all associated equipments and shifting work as specifiied in para 1(1.1)(a) part ii of rfp., lp air compressor, lp air compressor as specifiied in para 3 (3.1) part ii of rfp., dryer unit as specifiied in para 3 (3.1) part ii of rfp., air receiver tank (2000 liters) as specifiied in para 3 (3.1) part ii of rfp., air filter as specifiied in para 3 (3.1) part ii of rfp., acoustic canopy as specifiied in para 4 (4.1)(a) & (b) part ii of rfp., electric power distribution board/ control panel as specifiied in para 4 (4.1)(d) part ii of rfp., dismantling and degutting of shot blasting system along with all associated equipments and shifting work as specifiied in para 1.2 of part ii of rfp., shot blasting system, protection liner & rubber lining as specifiied in para 3(3.2) part ii of rfp., recovery unit as specifiied in para 3(3.2) part ii of rfp., dust collector & exhaust system as specifiied in para 3(3.2) part ii of rfp., shot blasting unit as specifiied in para 3(3.2) part ii of rfp., all other items associated with main eqipment which are mentioned in part ii of rfp [ex para 6(a) & 6(b) etc] part ii of rfp)., civil work for (refers to para 8 of part ii of rfp)., standard accessories (refers to para 9 of part ii of rfp), two years operation & maintenance spares (refers to para 10 of part ii of rfp), special maintenance tools and test equipment (refers to para 11 of part ii of rfp), technical literature / certificates / documentation (refers to para 13 of part ii of rfp), acceptance, testing, trials and commissioning charges (refers to para 14 of part ii of rfp), training (refers to para 16 of part ii of rfp), any other item such as transportation, insurance, freight, packing etc, notes:1. cost of item listed at sl 1 to 12 and 13 (if applicable) are to be quoted in the respective rows of the price bid sheet. 2. bidder not permitted to include cost of items listed at sl 6 to 13 with sl 1 to 5 as lumpsum amount 3. bidder required to mandatorily quote for sl 1 to 5 and 12 failing which bid shall be treated as non bonafide and liable for rejection.4. bidders are mandatorily to quote gst/ taxes as applicable against each serials, falling which bid shall be treated as non bonafide and liable for rejection.
Tender For annual operation and maintenance of electrical and mechanical works at rupsi airport - operation and maintenance of electrical and mechanical installations for 1st year , operation and maintenance of electrical and mechanical installations for 2nd year , job contract for operation and day to day maintenance services of airport systems equipments for 1st year , job contract for operation and day to day maintenance services of airport systems equipments for 2nd year , execution of item of schedule of rates cpwd dsr 2022 as and when required , testing of transformer oil sample including conducting bdv test and submission of test report etc complete as required , filtration of transformer oil of 630 kva transformer , supply of transformer oil conforming to is 335 1983 , servicing and checking of lt air circuit breaker , servicing and checking of ht vacuum circuit breaker , calibration and testing of relays at ht panel , calibration and testing of following relays at lt and synchronizing panel , scrubbing, cleaning the existing surface of cubicle panel, feeder pillars and painting , lettering of maximum 2 inch size alphabetic or numerical , cleaning the surface of ms chequered plates , supply and replacement of silica gel in breather of existing 630 kva transformer etc. complete as required , lifting and lowering of 10 hp borewell submersible motor pump set , servicing and complete overhauling of 10 hp borewell submersible motor pump set , decoration of terminal building and canopy of rupsi airport , supply and replacement of defective smoke detectors , supply and replacement of defective manual call point , maintenance and service of addressable two or one loop honeywell make fire alarm systems for 1st year , maintenance and service of addressable two or one loop honeywell make fire alarm systems for 2nd year , supply of convertor or driver suitable for philips make 20 w downlight types led luminaires or fittings , supply of convertor or driver suitable for osram make 120w types of led luminaires or fittings , supply of convertor or driver suitable for havells make 18 or 20 w downlight of led luminaires or fittings , supply of convertor or driver suitable for wipro make 36w 2ftx2ft recess mounted of led luminaires or fittings , supply of 1000w 240v lamp suitable for aerodrome beacon , supply of aerodrome beacon , calibration of clinometer , supply of minimum 10 meter high wheel driven telescopic ladder , supply of reflector , supply of 2c x 4 sq mm. secondary lead with plug , supply of b connector or four way porcelain terminal , supply of 5 kv grade 50 hz ac isolating transformer , supply of two pin halogen lamp holder suitable for 200 watt , supply of 5 w screw cap led lamp , supply of wind sock cloth , supply and replacement of led flood light , supply and replacement of obstruction light of wind direction indicator , supply and replacement of 180 ah 12 v lead acid battery , supply and replacement of 100 ah 12 v lead acid battery , supply of automaic electric hand drier , servicing, checking repairing overhauling and testing of crompton make 630 kva transformer for 1st year , servicing, checking repairing overhauling and testing of crompton make 630 kva transformer for 2nd year