Web Analytics Made Easy - StatCounter

Radiography Machine Tenders

Get complete information related to latest Radiography Machine Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Radiography Machine Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Radiography Machine Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :39656849 Due date: 25 Apr, 202525 Apr, 2025 NA
Tender For corrigendum : supply, installation and commissioning of digital mammography, fullroom digital radiography machine and highresolution colour doppler ultrasound unit

State Government

CTN :39714981 Due date: 16 Apr, 202516 Apr, 2025 87.1 Thousand
Tender For corrigendum : bm- service charges for conducting radiography (non- destructive test) on welding joints in pressure parts of unit-9 boiler during unit-9 annual overhaul works.

CTN :39876029 Due date: 08 Apr, 202508 Apr, 2025 11.00 Lacs
Tender For high frequency x-ray machine-, , , high frequency x-ray machine suitable for general radiography., , x-ray generator:, , high frequency x-ray generator having frequency of 50khz should be provided., , oil filled based generator for high dielectric strength, better heat dissipation, and easy service stability., , power output of generator should be 40 kw., , radiographic kv range should be 40 to 125kv., , ma range (rad.): upto 500ma., , exposure time (rad.): 2ms to 2sec., , mas range (rad.): 1 to 200mas., , control:, , a very compact, soft feather touch control panel having following functions & indications should be provided. the panel can be supplied in floor mount with spill proof design., , following features should be available on the control panel., , machine on/off switch., , digital display of kv & mas., , kv & mas increase and decrease switches., , tube focal spot selection switch., , ready and x-ray on switch with indicators, , bucky selection switch., , self diagnostic programme with indicators for earth fault error, kv error, filament error & tube's thermal overload., , anatomical preprogrammed parameters of human anatomy should be available to select exposure parameters based on body part, examination view and size of the patient., , anatomical programming up to 200 programmes or more, , a dual action hand switch with retractable cord should be provided for radiation protection of operator., , x-ray tube:, , one no. dual focus rotating anode x-ray tube thermally protected., , anode heat storage capacity of tube should be 140 khu., , one pair of 8-meter h.v. cable., , one no. collimator with auto shut off facility, should be provided., , hv tank:, , a very compact h.v. tank filled with high dielectric transformer oil should be provided. the h.v. tank should contain h.v. transformer, filament transformers, h.v. rectifiers & h.v. cable receptacles., , tube stand:, , floor mounted ceiling free tube stand with counter balanced movements & with easy installation at site., , manual movements with electromagnet locks in longitudinal, transverse & vertical movements are provided with release switches on electromagnet panel mounted on tube collimator assembly., , tilto meter on electromagnet panel to show tube angle position., , continuous tube rotation around horizontal axis with lock, , f. table:, , floatex table with 4-way movement of the table top i.e. along x axis and y axis is to be provided. longitudinal movement of tabletop is 500mm or more & transverse movement is 180mm or more., , the table should consists of bucky motorized reciprocating grid of ratio 8:1 - 85 lines/inch., , the bucky should be locked at any desired length position by an electromagnetic lock., , the tabletop should be made of low radiation absorption, waterproof material., , table accessories like stainless steel cassette tray, compression band is to be provided., , g. vertical bucky stand:-, , vertical bucky stand with oscillating grid of ratio 8:1, 85 lines / inch is provided., , the bucky moves up & down & is equipped with a stainless steel cassette tray., , the stand is floor-mounted type & can accommodate cassettes up to 14" x 17". the bucky is tilted in 6 steps of 15 degree angle each for various radiographs., , vbs should have provision for without grid exposure., , power requirement: the unit should be, , operable on 3 phase, 400 volts ac 50hz with line resist less than 0.2 ohms. line regulation 10%., , other requirements:, , the company should be iso & icmed certified company., , the unit should be approved by aerb., , the company should be european ce certified from notified body., , the equipment should have import/manufacturing, ,

CTN :39601733 Due date: 03 Apr, 202503 Apr, 2025 NA
Tender For procurement of medical equipment for pt jln govt medical college chamba - cost of core equipment (digital mammography) (inr) including supply, installation and commissioning as required in the technical specification along with accessories and 3 years warranty., cost of core equipment (full room digital radiography machine) (inr) including supply, installation and commissioning as required in the technical specification along with accessories and 3 years warranty., cost of core equipment (high-resolution colour doppler ultrasound unit) (inr) including supply, installation and commissioning as required in the technical specification along with accessories and 3 years warranty., note a) the basic price of the goods to be quoted without gst.b) the cmc should be quoted year wise without gst.c) cmc rate and turnkey work (if any) shall be included for determining l-1 bidder.d) gst shall be payable as applicable from time to time.e) charges towards packing & forwarding, inland transportation, insurance (local transportation and storage) would be borne by the supplier from warehouse to the consignee site, loading/unloading and other local costs incidental to delivery of the goods to their final destination as per section i (h.p) shall also be borne by the supplier.f) the price should be inclusive of supply, installation, commissioning charges.g) l-1 will be determined equipment-wise on total basic price of the equipment including accessories (excluding gst) + total cmc (excluding gst) +turnkey work (if any), excluding gst , for the items/consignee as mentioned in section-i.it is certified that the cost of goods shown above, is all inclusive except gst. signature of authorizedsignatory with seal
 Loading, Please wait...

Connect us via What's Up