Tender For tender for supply of supply and installation commissiong d d -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1392 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply the indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1 2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required , supply and fixing of 75mm dia minimum 18mm thickness pvc covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25 x 25x5mm l angle frame including clamps bolts nuts vibrating dampers as required , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealed scroll rotary compressor and eco friendly refrigerant initial charge of refrigerant condensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor laying and interconnection of standard length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of beyond the standard length supplied by the oem copper refrigerant pipe of size suitable for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation for hi wall split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 75mm dia minim
Tender For building nirman samagri - cement 53 grade, major plant (isi) mark (50 kg per bag), iron rebar tested 6 mm (isi) mark, iron rebar tested 8 mm (isi) mark, iron rebar tested 10 mm (isi) mark, iron rebar tested 12 mm (isi) mark, iron rebar tested 16 mm (isi) mark, binding wire, nails kg, sand rail, black sand, gravel 20 mm, gravel 40 mm, gravel 63 to 45 mm, boulders, stone dust, murum, cumin gravel, gravel sand, heavy road roller vibrator rental per hour, kota stone, palai ash bricks (20 x 10 x 10 cm), red bricks (20 x 10 x 10 cm), aluminum section (window) with isi-marked glass and mosquito net, flush door with mixed-species wood frame and fittings with holedrops, complete size 3 feet 6 inches x 7 feet, flush door with mixed-species wood frame and fittings with holedrops, complete size 2 feet 9 inches x 7 feet, concrete paver blocks with interlock color, bathroom tiles 1.5 x 1.5, ceramic glass first quality tiles size 500x500x9.10 mm, iron window grill, iron ventilation, pvc pipe 2" length 20 feet, pvc pipe 4" length 20 feet, pvc pipe 6" length 20 feet, corrugated tin sheet 4x12
Tender For providing of repair and overhauling service - construction work of type 1 awaas type i,ii,iii; construction work of type 1 awaas type i,ii,iii; no; buyer premises rcc framed & filler walls of aerated cement concrete (acc) cellular concrete block (clc) brick work/fly-ash brick
Tender For protection of spillway channel towards basati nallah rd 123 to 130 m by providing wire crate wall and cement concrete work which was damaged due to heavy rainfall during monsoon 2025