Tender For supply of electrical items as per annexure-d at sonari lignite project, rsmml, ceu lignite office, barmer - providing & fixing of 240/415 v residual current circuit breaker (rccb) conforming to (is:12640-1)/ iec 61008 -1 , rated 4 kv impulse withstand voltage truly current operated and shall operate on cbct mechanism, provision for pad lock, min. operation 10,000 up to 63 a rating and 5000 for 100 a rating and minimum phase termination capacity of 35 sq.mm. rigid wire, ip 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. rccb 63 amp, 4 pole rccb 100 amp, 4 pole, providing & fixing of iso certified company made tp&n, 415 v ac-23a front handle operated switch disconnector fuse unit, cubical type, without metallic enclosure (for panel mounting), as per pwd specification for electrical works conforming to is/iec 60947-3 : 1999 in existing panel with hbc fuses including making connections with lugs, testing etc as required sfu (switch fuse unit), 63 amp, 3 pole with handle, providing & fixing of 240/415 v ac mcb with positive isolation of 10ka breaking capacity (8/ c/d tripping characteristic as per type of load and site requirement) 4 kv impulse withstand voltage, lsi marked is 8828(1996) / conforming to iec 60898-1 2002, iec 60947- 2, low watt losses, trip free mechanism, energy limiting of class 3 as per iec, minimum phase termination capacity of 35 sq.mm. conductor line load reversibility, ip 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 up to 20 a rating and 10,000 up to 63 a, 5000 for 80 a & above rating including making connections, testing etc. as required. single pole mcb 6a to 32 amp double pole mcb 6a to 32 amp, lightening arrester, sis heavy duty 9 kv, 10 ka, pipe earthing as per is:3043- 1987 with 3.0 mtr. long, 40 mm dia. ' b ' class g.!. pipe is: 1239 (part-1) 2004, equivalent to bs : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and heavy duty weather proof polypropylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal. all as per pre approved by engineer in charge., providing and fixing 180 cm high fencing with angle iron post size 50x50x6mm placed at every 3 meters apart and 45cm in ground embedded in cement concrete 1:3:6 (30x30x60cm) corner and every 10th.post to the strutted with sox50x6 mm angle iron provided with 6 horizontal lines and 2diagonals of g.l. barbed wire between two post fitted and fixed with g.i. staples including each works in excavation etc. complete., supply & laying following size earth strip in horizontal or vertical run in surface by means of earth strip dmc insulator including riveting/ soldering/ welding, jointing shall be done by overlapping and with 2 set of brass (for cu strip) / gi (for gi strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. all as per pre approved by engineer in charge. 25x3 mm copper strip 30mm x 6mm alum. strip, providing & fixing of iso certified company made lightning conductor finial as per pwd specification for electrical works as per is 2309-1989 made out of 25 mm dia.,300 mm long copper solid rod having single prong at top with 85 mm dia., 3 mm thick copper base plate including holes etc. complete as required. all as per pre approved by engineer in charge.
Tender For supply of electric items as per annexure-d at giral lignite project, rsmml, ceu lignite office, barmer. - p & fixing powder coated crca sheet enclosures on existing angle iron frame by means of nuts and bolts and making holes, din rail etc. as required 2.5 mm thick., providing & fixing of 240/415 v residual current circuit breaker (rccb) conforming to (ls:12640-1)/ iec 61008 -1 , rated 4 kv impulse withstand voltage truly current operated and shall operate on cbct mechanism, provision for pad lock min. operation 10,000 up to 63 a rating and 5000 for 100 a rating and minimum phase termination capacity of 35 sq.mm. rigid wire, ip 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. rccb 63 amp, 4 pole, providing & fixing of iso certified company made tp&n, 415 v ac-23a front handle operated switch disconnector fuse unit, cubical type, without metallic enclosure (for panel mounting), as per pwd specification for electrical works conforming to is/iec 60947-3 : 1999 in existing panel with hbc fuses including making connections with lugs, testing etc as required sfu (switch fuse unit), 63 amp, 3 pole with handle, providing & fixing of 240/415 v ac mcb with positive isolation of 10ka breaking capacity (b/ c/d tripping characteristic as per type of load and site requirement) 4 kv impulse withstand voltage, lsi marked is 8828(1996) / conforming to iec 60898-1 2002, iec 60947- 2, low watt losses, trip free mechanism, energy limiting of class 3 as per iec, minimum phase termination capacity of 35 sq.mm. ,conductor line load reversibility, ip 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 up to 20 a rating and 10,000 up to 63 a, 5000 for 80 a & above rating including making, connections, testin~ etc. as re_quired., single pole mcb 6a to 32 amp, double pole mcb 6a to 32 amp pipe earthing as per is:3043- 1987 with 3.0 mtr. long, 40 mm dia . ' b ' class g.!. pipe is: 1239 (part-1) 2004, equivalent to bs : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and heavy duty weather proof polypropylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal. all as per pre approved by engineer in charge., providing and fixing 180 cm high fencing with angle iron post size 50x50x6mm placed at every 3 meters apart and 45cm in ground embedded in cement concrete 1:3:6 (30x30x60cm) corner and every 10th.post to the strutted with 50x50x6 mm angle iron provided with 6 horizontal lines and 2diagonals of g.!. barbed wire between two post fitted and fixed with g.!. staples including each works in excavation etc. complete., supply & laying following size earth strip in horizontal or vertical run in surface by means of earth strip dmc insulator including riveting/ soldering/ welding, jointing shall be done by overlapping and with 2 set of brass (for cu strip) / gi (for gi strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. all as per pre approved by engineer in charge. 25x3 mm copper strip 30mm x 6mm alum. strip, providing & fixing of iso certified company made lightning conductor finial as per pwd specification for electrical works as per is 2309-1989 made out of 25 mm dia.,300 mm long copper solid rod having single prong at top with 85 mm dia ., 3 mm thick copper base plate including holes etc. complete as required. all as per pre approved by engineer in charge. providing & fixing of recessed/surface mounting heavy duty enclosure made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is-8623-1 & 3 / iec 61439- 1 & 3. powder painted complete with din rail making i
Tender For bid to ras corrigendum : sitc of 2 x 33 tr air cooled package type air conditioning plants - supply, installation, testing , commissioning of 33 tr capacity air cooled airconditioner , supply, installation, testing commissioning of 33tr capacity ,13200 cfm horizontal floor mounted double skin air handling unit , supply, installation, testing and commissioning of 3 phase vfd drives , supply and laying of 19 g copper pipe of size one and one eighth inches copper pipe for suction line with nitrile rubber insulation of 19mm thick , supply and laying of 19 g copper pipe of size five eighths inch with 13mm thick insulation for liquid line , supply, installation and testing of gss construction of 16g opposed blade volume control dampers , supply and installation of g.i perforated cable tray with top cover with supports , modification of existing plenum chamber , supply and installation of 32 mm dia cpvc or upvc drain piping insulated with 9mm nitrile rubber for ahu , supply installation testing and commissioning of electric control panel , supply and installation of remote status indication panel at control room , earthing , providing heat insulation treatment in ac plant room , providing under deck insulation , providing iron angle platform arrangement for outdoor condensing units , supply of 2 ft x 2 ft return air grills , provision of indicators for filter clogging and condenser clogging , dismantling and shifting of existing units , cooling towers, ahus , any other materials or works requirement to complete the sitc , belts for blower , pressure gauges for refrigerant and oil , dial type thermometer , air-filters , empty gas cylinder with regulating valve adopter and pressure gauge. , liquid line strainer , whirling psychro meter , anemometer , thermometer , valve key , thermal insulation of exposed duct out side the building bid number/ ( ( ) ): gem/2024/b/5460049 dated/* : 03-10-2024 bid document/ 2 1 / 28
Tender For supply of diameter , ppr end cap 20mm diameter , thread gola , ppr pipe 20mm diameter , pvc swr pipe of 100mm dia , pvc elbow 100mm dia , pvc tee 100mm dia , pvc coupler 100mm dia , pvc bend 100mm dia , pvc swr pipe of 75mm dia , pvc pipe 100mm dia , pvc floor trap 75 dia , pvc tee 75mm dia , pvc elbow 75mm dia , pvc coupler 75mm dia , pvc cowl 100mm dia , adhesive for pvc pipe fixing , anaerobic septic tank 1000ltrs , soak pit chamber , gi earthing plate , common salt , charcoal , gi wire 4mm 8 swg , ci cover 5mm thick , gi funnel with wire mesh , rawl plug , screw steel full threaded 32 mm , gi pipe 20mm dia 6 feet long , gi pipe 50mm dia 6 feet long , surface and wall mounted led tube rod , pixel bulk head fittings , surface and wall mounted led , ceiling fan 1200 mm sweep , exhaust fan 300mm sweep , pvc insulated heavy duty 1100 volt , 10 ltr water storage geyser plastic body , porcelain insulating hangers , pvc copper conductor cable 1 sqmm , pvc copper conductor cable 1 point 5 sqmm , pvc copper conductor cable 2 point 5 sqmm , pvc copper conductor cable 4 sqmm , modular switch piano flush type 6 , modular switch piano flush type 16 , modular socket outlet multipurpose 2 oblic 3 pin , modular socket outlet multipurpose 2 in 1 , surface mounting plastic boxes 12 switches , surface mounting plastic boxes 8 switches , surface mounting plastic boxes 6 switches , surface mounting plastic boxes 4 switches , combined cover plate with frame 12 module , combined cover plate with frame 8 module , combined cover plate with frame 6 module , combined cover plate with frame 4 module , blanking plate for modular switch socket , ceiling rose with square box , flexible pipe , pvc pipe 20mm dia , pvc elbow for 20mm dia , pvc space bar saddles for 20mm dia , pvc coupler for 20mm dia , pvc tee for 20mm dia pvc pipe , 25mm pvc casing capping , pvc coupler for 25mm casing capping pipe , pvc tee for 25mm casing and capping pipe , pvc socket for 25mm casing and capping pipe , pvc elbow for 25 mm casing and capping pipe , pvc corner bend for 25 mm , pvc junction box two way 20mm dia , pvc junction box three way 20mm dia , pvc junction box four way 20mm dia , pvc junction linker , house service bracket , mcb db 8 way spn , mcb 10 a sp 240 volt , mcb 20 a spn 240 volt , mcb 40 a dp 240 volt , insulation tape 19mm width , no 8 x 19 csk screw , no 8 x 32 csk screw , no 8 x 50 csk screw , no 8 x 75 bolts and nuts full threaded. , lc set with safe chemical
Tender For repair maintenance and replacement of lightning protection system earthing and earth chamber earth test point at various location at sukna and u area under ge sukna