Get complete information related to latest Respiratory Devices Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Respiratory Devices Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Respiratory Devices Tenders.
Tender For high frequency x-ray machine-, , , high frequency x-ray machine suitable for general radiography., , x-ray generator:, , high frequency x-ray generator having frequency of 50khz should be provided., , oil filled based generator for high dielectric strength, better heat dissipation, and easy service stability., , power output of generator should be 40 kw., , radiographic kv range should be 40 to 125kv., , ma range (rad.): upto 500ma., , exposure time (rad.): 2ms to 2sec., , mas range (rad.): 1 to 200mas., , control:, , a very compact, soft feather touch control panel having following functions & indications should be provided. the panel can be supplied in floor mount with spill proof design., , following features should be available on the control panel., , machine on/off switch., , digital display of kv & mas., , kv & mas increase and decrease switches., , tube focal spot selection switch., , ready and x-ray on switch with indicators, , bucky selection switch., , self diagnostic programme with indicators for earth fault error, kv error, filament error & tube's thermal overload., , anatomical preprogrammed parameters of human anatomy should be available to select exposure parameters based on body part, examination view and size of the patient., , anatomical programming up to 200 programmes or more, , a dual action hand switch with retractable cord should be provided for radiation protection of operator., , x-ray tube:, , one no. dual focus rotating anode x-ray tube thermally protected., , anode heat storage capacity of tube should be 140 khu., , one pair of 8-meter h.v. cable., , one no. collimator with auto shut off facility, should be provided., , hv tank:, , a very compact h.v. tank filled with high dielectric transformer oil should be provided. the h.v. tank should contain h.v. transformer, filament transformers, h.v. rectifiers & h.v. cable receptacles., , tube stand:, , floor mounted ceiling free tube stand with counter balanced movements & with easy installation at site., , manual movements with electromagnet locks in longitudinal, transverse & vertical movements are provided with release switches on electromagnet panel mounted on tube collimator assembly., , tilto meter on electromagnet panel to show tube angle position., , continuous tube rotation around horizontal axis with lock, , f. table:, , floatex table with 4-way movement of the table top i.e. along x axis and y axis is to be provided. longitudinal movement of tabletop is 500mm or more & transverse movement is 180mm or more., , the table should consists of bucky motorized reciprocating grid of ratio 8:1 - 85 lines/inch., , the bucky should be locked at any desired length position by an electromagnetic lock., , the tabletop should be made of low radiation absorption, waterproof material., , table accessories like stainless steel cassette tray, compression band is to be provided., , g. vertical bucky stand:-, , vertical bucky stand with oscillating grid of ratio 8:1, 85 lines / inch is provided., , the bucky moves up & down & is equipped with a stainless steel cassette tray., , the stand is floor-mounted type & can accommodate cassettes up to 14" x 17". the bucky is tilted in 6 steps of 15 degree angle each for various radiographs., , vbs should have provision for without grid exposure., , power requirement: the unit should be, , operable on 3 phase, 400 volts ac 50hz with line resist less than 0.2 ohms. line regulation 10%., , other requirements:, , the company should be iso & icmed certified company., , the unit should be approved by aerb., , the company should be european ce certified from notified body., , the equipment should have import/manufacturing, ,
Tender For supply of necessary equipment and materials to the lab under nppcf programme.-, lon meter & accessories to be supplied with equipment, , -- comsumable item-, , medico centrifuge salient features:-, , laboratoryinc ubator-bottomheater type, , magnetic stirrer m cum hot plate -250 w, , n, , a, , l, , micropipette (fix volume) 1ml a, , micropipette (fix volume) 10 ml, , micropipette stand, , dropping bottle, , b test tube stand t, , bucket for waste s disposable, , a, , msumable item-, , -, , tip for 1 micropipette 1ml, , ., , tip for 2 micropipette a 10ml, , 1.3, , 3.4, , for film roll, , white paper stickers, , distill water bottle 5l, , be text], edta vial, , and, , the, , diagnostic hand gloves, , test tube, , t, , tissue paper roll, , t, , mouth mask, , spirit, , s, , c, , c, , disposable sterile syringe, , cotton roll, , fluoride standard (100 f ppm), , 5 tisab ii, , 5 tisab iii, , plastic bag for disposable, , 7 waste