Web Analytics Made Easy - StatCounter

Structural Engineer Consultancy Tenders

Get complete information related to latest Structural Engineer Consultancy Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Structural Engineer Consultancy Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Structural Engineer Consultancy Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :39873797 Due date: 07 Apr, 202507 Apr, 2025 NA
Tender For repair and overhauling service - upgradation of gym interior of officers gym; interior design; yes; buyer premises: augmentation of interior designing for officers' gymanisum -ins vishw rma-1 false ceiling-providing and fixing suspended false ceiling of armstrong or equivalent (fine fissured micro look with silhouette grid) equivalent of size 600mm x 600mm at all levels fixed with channels & hanger rods & making cut outs for all led lights etc including all material, labour and transportation as per approved sample designs, drawings and specifications as directed by the officer in-charge. item includes dismantling of old ceiling and disposal of the malba. providing ducting after making necessary connections from the main duct . the work has to be executed in co-ordination with the air conditioning system agency and with the officers monitoring the ac system 2) wooden ceiling providing of faux beams in the ceiling as part of the design of the false ceiling. beam size shall be 8" x 8" as per texture and colour finalized . the installation has to be carried out maintaining the aesthetics of the area and as per design finalized including all material, labour, transportation as per approved sample designs, drawings and specifications as directed by the buyer 3) electrical wiring : providing & fixing of 25mm electrical conduits of make akg/polypack/setia or equivalent making chasing in walls & finishing it with plaster making it good for painting & pvc insulated copper wires of finolex/havells or equivalent as per approved samples, design, drawings, specifications & as directed by the buyer, item includes removal of the old wiring and disposal of the malba 4) light fixtures downlighters : providing & installation of led downlighters of 5000k of reputed brand jaguar/philips/legero/syska as per approved samples, design, drawings, specification and as directed by the buyer with testing and commissioning. item includes dismantling of old lights and buy back of old lights with fittings and disposal of all malba 5) track lights & spot lights spot lights : providing & installation of 9w cob lights of reputed brand jaguar/philips/legero/syska as per approved samples, design, drawings, specifications and as directed by the buyer 6) magnetic track lights : providing of suspended magnectic tracks of reputed brand philips/jaguar/ legero/syska or equivalent including 200w integrated power supply, trimless wall corner l jointer for magnetic track channel and hanging kit set. providing of 20w linear laser tiltable spotlight with a combination of cone pendant light as per approved samples, design, drawings, specifications and as directed by the buyer 7) switches/sockets & switch boards providing of switches sockets and all the switch boards of reputed brand i.e. schneider/norisys as per approved samples, design, specifications and as directed by the buyer 8) ceiling and wall painting cleaning and sanding of the surface of the ceiling and wall and application of 1st coat of oil base primer. upon drying of primer, application of 2 coats of birla wall putty. upon drying, sanding the surface to a smooth seamless finish and application of 2nd coat of oil base primer. upon dring of the primer application of 3 coats of emulsion of royale teflon finish as per approved samples, specifications and as directed by the buyer 9) wall panelling providing and fixing in position wall panelling at all heights with pvc wall panel/sheets (5-9mm thickness) of approved texture, design and patterns having nrc (noise reduction co-efficient) of 0.50 (minimum), light reflectance of 85% (minimum). non combustible fire performance as per bs:476 , humidity resistance of 100% , thermal conductivity <0.043 w/m k comprising of frame made in the wall from specially fabricated galvanized mild sheet 0.50mmthk pressed section (galvanizing @120grams per sqm including both sides) i.e. vertical studs of size 48 x 34 x 36 fixed to the floor and sof

CTN :39876029 Due date: 08 Apr, 202508 Apr, 2025 11.00 Lacs
Tender For high frequency x-ray machine-, , , high frequency x-ray machine suitable for general radiography., , x-ray generator:, , high frequency x-ray generator having frequency of 50khz should be provided., , oil filled based generator for high dielectric strength, better heat dissipation, and easy service stability., , power output of generator should be 40 kw., , radiographic kv range should be 40 to 125kv., , ma range (rad.): upto 500ma., , exposure time (rad.): 2ms to 2sec., , mas range (rad.): 1 to 200mas., , control:, , a very compact, soft feather touch control panel having following functions & indications should be provided. the panel can be supplied in floor mount with spill proof design., , following features should be available on the control panel., , machine on/off switch., , digital display of kv & mas., , kv & mas increase and decrease switches., , tube focal spot selection switch., , ready and x-ray on switch with indicators, , bucky selection switch., , self diagnostic programme with indicators for earth fault error, kv error, filament error & tube's thermal overload., , anatomical preprogrammed parameters of human anatomy should be available to select exposure parameters based on body part, examination view and size of the patient., , anatomical programming up to 200 programmes or more, , a dual action hand switch with retractable cord should be provided for radiation protection of operator., , x-ray tube:, , one no. dual focus rotating anode x-ray tube thermally protected., , anode heat storage capacity of tube should be 140 khu., , one pair of 8-meter h.v. cable., , one no. collimator with auto shut off facility, should be provided., , hv tank:, , a very compact h.v. tank filled with high dielectric transformer oil should be provided. the h.v. tank should contain h.v. transformer, filament transformers, h.v. rectifiers & h.v. cable receptacles., , tube stand:, , floor mounted ceiling free tube stand with counter balanced movements & with easy installation at site., , manual movements with electromagnet locks in longitudinal, transverse & vertical movements are provided with release switches on electromagnet panel mounted on tube collimator assembly., , tilto meter on electromagnet panel to show tube angle position., , continuous tube rotation around horizontal axis with lock, , f. table:, , floatex table with 4-way movement of the table top i.e. along x axis and y axis is to be provided. longitudinal movement of tabletop is 500mm or more & transverse movement is 180mm or more., , the table should consists of bucky motorized reciprocating grid of ratio 8:1 - 85 lines/inch., , the bucky should be locked at any desired length position by an electromagnetic lock., , the tabletop should be made of low radiation absorption, waterproof material., , table accessories like stainless steel cassette tray, compression band is to be provided., , g. vertical bucky stand:-, , vertical bucky stand with oscillating grid of ratio 8:1, 85 lines / inch is provided., , the bucky moves up & down & is equipped with a stainless steel cassette tray., , the stand is floor-mounted type & can accommodate cassettes up to 14" x 17". the bucky is tilted in 6 steps of 15 degree angle each for various radiographs., , vbs should have provision for without grid exposure., , power requirement: the unit should be, , operable on 3 phase, 400 volts ac 50hz with line resist less than 0.2 ohms. line regulation 10%., , other requirements:, , the company should be iso & icmed certified company., , the unit should be approved by aerb., , the company should be european ce certified from notified body., , the equipment should have import/manufacturing, ,

CTN :39872827 Due date: 01 Apr, 202501 Apr, 2025 NA
Tender For providing of design, supply, installation, commissioning and maintenance of grid connected roof top solar power plant service - 163; 1; self-owned

Central Government/Public Sector

CTN :39791969 Due date: 02 Apr, 202502 Apr, 2025 1.85 Lacs
Tender For corrigendum : consultancy service for preparation of structural and architectural design drawing and soil testing for construction of toe wall rcc storm water drain and earthern drain for newly constructed 304 nos type ii residential quarters at gc crpf bangalore

Central Government/Public Sector

CTN :39841868 Due date: 03 Apr, 202503 Apr, 2025 6.31 Lacs
Tender For construction of 40 bedded women barrack at bsf campus dholchera of 170 bn bsf under shq bsf silchar (sh - structural design and drawing, geotechnical investigation of soil, consultancy service and visit charge)

Central Government/Public Sector

CTN :39841869 Due date: 03 Apr, 202503 Apr, 2025 8.19 Lacs
Tender For construction of quarter guard, kote, magazine at bn hq satakha (nagaland) of 111 bn bsf under shq bsf ci(ops) manipur (sh - structural design and drawing, geotechnical investigation of soil, consultancy service and visit charge)

CTN :39722202 Due date: 31 Mar, 202531 Mar, 2025 2.80 Lacs
Tender For corrigendum : providing of facility management services - lumpsum based - government land; consultancy services for structural design; consumables to be provided by service provider (inclusive in contract cost)

CTN :37723613 Due date: 04 Apr, 202504 Apr, 2025 NA
Tender For corrigendum : supply of hvac and accommodation for bangladesh dredger project yard 2121 - design and supply of ac plant and acesories_590100000104_1000055078_2121 , on board spares for ac_590100950050_1000055078_2121 , documentation for ac_590100960005_1000055078_2121 , tools for ac_590100920100_1000055078_2121 , instl and comm spares for ac_590100910100_1000055078_2121 , training for ac plant_ser06304_1000055078_2121 , service intlln_stw_hat_sat_commissioning_ser00295_100005 5078_2121 , submission of binding data_590100960100_1000055078_2121 , design and suply of hvac sys_equpt and accesors_597100000209_1000055078_2121 , on board spares for hvac_597100009518_1000055078_2121 , documentation for hvac_597100009605_1000055078_2121 , tools for hvac_597100009206_1000055078_2121 , services for installation of equipment_ser00298_1000055078_2121 , suppy_erection of cw pipes_v-v and fittings_ser00299_1000055078_2121 , training for hvac system_ser00316_1000055078_2121 , service intlln_stw_hat_sat_commissioning_ser00317_100005 5078_2121 , supply of accommodation material_590100000105_1000055078_2121 , mtc for accommodation material_590100960006_1000055078_2121 , installation of accommodation material_ser10506_1000055078_2121 , warranty extension charge for 1st year-2121 , warranty extension charge for 2nd year-2121 bid number/ ( ( ) ): gem/2024/b/5454640 dated/* : 30-09-2024 bid document/ 2 1 / 24

CTN :39722707 Due date: 04 Apr, 202504 Apr, 2025 12.03 Lacs
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; design supply installation and commissioning of vibratory screen unit with suitable motor and all other accessories; service provider

CTN :39835901 Due date: 28 Mar, 202528 Mar, 2025 NA
Tender For providing of design, supply, installation, commissioning and maintenance of grid connected roof top solar power plant service - 163; 1; self-owned
 Loading, Please wait...

Connect us via What's Up