Tender For corrigendum : supply and installation of ip54 protected glass fiber reinforced polycarbonate double insulated power distribution board of dimension 1200 x 1300 x 274mm. the enclosure must be of double insulated, haloge free with high impact resistance of ik08 (5 joules) according to iec 62262. the enclosure should be made of uv resistant material, corrosion free. the enclosure material used should be self-extinguishing up to 960 deg with working temperature from -35 degc to +80 degc. interconnection between the enclosures in the panels should be made with accessories which should maintain with same ip protection rating of ip65. the enclosure gasket materials shall be injected polyurethane. the enclosure should be made of the same polycarbonate materials only. incomer: 400a fp mccb 36ka - 1 no and 230v ac r,y,b indicating lamp, digital multi-function meter with 400/5a current transformer and outgoing: 100a tp mccb 36ka with 100a neutral link - 7 nos & 63a fp mcb 10ka - 2 nos with 70a tp ac3 contactor control with 24hrs digital timer with auto/manual selector switch and push buttons for manual operations .copper busbar rating of 400a - 30 x 10 for all phases and neutral should be used -provision for termination of 185 sq.mm in incomer and 35 sq.mm cables for 100a outgoing, 16 sq.mm cables for 63a outgoing and all mccb should have an adjustable setting range (in) from 70% to 100%, each mccb should have extended rotary handle for easy operation. the manufacturer should submit all the test certificates in accordance with iec 61439, routine test report must be made with high voltage test, insulation resistance test, functional test. the wall mounting frame should be made of hot dip galvanized materials. 1) acceptable make :cape/ famatel/hensel/rittal/abb with following switch gear and terminals fixed in the junction box as per drawing enclosed. 2)terminal block make: connect well/ elmex. 3)switch gears make shall be abb/l&t /eaton/siemens,havells,c&s. [ warranty period: 12 months after the date of delivery ]
Tender For corrigendum : supply of spares for different laboratory instruments on rate contract basis for 03 (three) years at head water works - replacement of sensor cap (ldo on line sensor), keypad for 2100p turbidity meter, sample cell /civettes for pocket colorimeter, frc, electrolyte sol for 9184sc chlorine analyser, membranes for 9184sc chlorine analyser, sample cell,1 in round glass,10, ml,w/cap,pk/6 for 2100 portable turbidity, maintenance kit, 1 year, includes tubing, caps,, funnel and fittings for cl17, for on line ph sensor salt bridges for dpdr1, tungsten lamp for spectrophotometer, (dr5000/ dr6000), tungsten (vis) lamp for spectrophotometer, (dr2000), cl17 free chlorine reagent set, lamp for 2100p turbidity meter, lamp assembly for 1720e turbidity meter, do cap for hq40d do meter, key pad for 2100q turbidity meter, keypad for surface scatter, do probe service kits for mm 378 benchtop, meter, lamp assembly for surface scatter 6/7 sc, tubing replacement kit for surface scatter 6/7, sc, filter holder f/wavelength selection for, dr5000, deauterium lamp for spectrophotometer, (dr6000), filter wheel with glasses for spectrophotometer, (dr6000), filter motor for spectrophotometer (dr6000), filling solution, 50 ml for benchtop do meter, replacement membranes for benchtop do meter, free chlorine reagent, 1000 test for pocket, colorimeter, digital extension cable (7 m) for sc1000, digital extension cable (1 m) for sc1000, wiper blades, replacement only, pkg. of 5, ldo10101 sensor cap, sc200 keypad, membranes for hanna hi 9146 do meter, electrolyte sol for hanna hi 9146 do meter, lamp hanna hi 98703-02 turbidity meter, reagent for hanna hi 96734c pocket, colorimeter, 9v battery for hanna hi 96734c pocket, colorimeter, power adaptor for hanna make ph meter, keypad for conductivity meter sension +ec71, power module for turbidity meter 21100q, cl17 lamp, stir bar for cl17, colorimeter assembly, mirror lamp, mirror, gratting, gratting with holder, filter wheel motor, lamp, 15 m cable, sensor cap for do online (wtw), sensor for tw (do) (wtw), conductivity electrode (wtw), keypad for dr1900 spectrophotometer (hach), tep 4 (buffer solution), tep 7 (buffer solution), ac power/usb adapter kit, 230 vac for hq40d, do meter, electrode for hanna hi 2215 ph meter, temp probe for for hanna hi 2215 ph meter, electrode for hanna hi 2300 tds meter, sensor for hanna hi 9146 do meter, sensor for hanna hi 5321-02 tds/conductivity, meter,1m cable,platinum 4 ring, sensor for hanna hi 2002-02 ph meter with, temp sensor, ph probe for online sc 9184 chlorine meter, ph electrode phc3005-8, w/bnc radio meter, ph meter, do probe with 3 mtr .cable for sension series, temperature probe (sensor), for ion450 ph, meter, ph electrode for online ph meter, do probe of online ldo sensor, 1720e turbidity meter, sensor only, intellical lbod probe, standard, with 1.8, m cable, sension 5131- sensor for mm 378 benchtop, meter, 5010 t combination ph electrode for ph31, glp laboratory ph meter, 5070 conductivity probe for ec71 glp, conductivity meter, conductivity probe for +ec5 conductivity meter, sension+ ph gel electrode with ceramic, diaphragm, sc200 controller, 2 channel, digital, sension ph combination gel electrode, conductivity electrode for sension+5, 9184 chlorine sensor, contacting conductivity sensor, hall sensor plate, main board, ph electrode, dissolved oxygen probe by fluorescence with, auto cleaning, turbidity probe, ph on-line electrode, general purpose, conductivity module, conductivity online electrode, k=0.1, turbidity cylinder for low range, replacement electrode for cl2 set, replacement membrane for cl2 electrode echl, refillable electrolyte (125 ml) for cl2 electrode, echl, flowmeter with valve for cl2 set (6-60 l/h), el200 board, lcd colour screen (tft), 4-20 ma output module, sensolyt sea (ph electrode), standard 1000 fnu, tecl-kit chlorine 3000, ftcl-kit chlorine 3000, clf-kit 30, sc-fdo 701, controller, power circuit for hq430d conductivity/tds, hach),
Tender For supply of electrical ee2 d d -experimental kit for the measurement of displacement using lvdt 6 , experimental kit for the measurement of displacement using lvdt 7 , inductive load bank 1 , inductive load bank 2 , kelvin double bridge 1 , kelvin double bridge 2 , kelvin double bridge 3 , kelvin double bridge 4 , kelvin double bridge 5 , kelvin double bridge 6 , m. i type analog ammeter 0 1 a 1 , m. i type analog ammeter 0 1 a 4 , m. i type analog ammeter 0 1 a 2 , m. i type analog ammeter 0 1 a 3 , m. i type analog ammeter 10 20 a , m. i type analog ammeter 2. 5 5 a 1 , m. i type analog ammeter 2. 5 5 a 2 , m. i type analog ammeter 5 10 a 1 , m. i type analog ammeter 5 10 a 2 , m. i type analog ammeter 5 10 a 3 , m. i type analog ammeter 5 10 a 4 , m. i type analog ammeter 5 10 a 5 , megger hand driven 1 , megger hand driven 2 , megger hand driven 3 , megger hand driven 4 , megger hand driven 5 , mi type analog voltmeter 125 250 500v , mi type analog voltmeter 300 600v 1 , mi type analog voltmeter 300 600v 2 , mi type analog voltmeter 300 600v 3 , mi type analog voltmeter 300 600v 4 , mi type analog voltmeter 300 600v 5 , mi type analog voltmeter 75 150 300v 1 , mi type analog voltmeter 75 150 300v 2 , mi type analog voltmeter 75 150 300v 3 , network theorem trainer kit 1 , network theorem trainer kit 2 , network theorem trainer kit 3 , orifice meter measurement setup 1 , orifice meter measurement setup 2 , orifice meter measurement setup 3 , phase sequence indicator 1 , phase sequence indicator 2 , rheostat 0 100 ohm,2. 5a , rheostat 0 100 ohm,5a 1 , rheostat 0 100 ohm,5a 2 , rheostat 0 250 ohm, 2. 5 a 1 , rheostat 0 250 ohm, 2. 5 a 2 , rheostat 0 250 ohm,1a , rheostat 0 50 ohm,5a , rheostat 0 500 ohm, 2. 5 a , rotameterflow measurement setup 1 , rotameterflow measurement setup 2 , rotameterflow measurement setup 3 , rtd temperature measurement setup 1 , rtd temperature measurement setup 2 , strain gauge trainer kit 1 , strain gauge trainer kit 2 , strain gauge trainer kit 3 , strain gauge trainer kit 4 , strain gauge trainer kit 5 , strain gauge trainer kit 6 , three phase load rheostat 1 , three phase load rheostat 2 , three phase load rheostat 3 , three phase load rheostat 4 , three phase load rheostat 5 , three phase power factor meter 1 , three phase power factor meter 2 , three phase power factor meter 3 , three phase power factor meter 4 , three phase power factor meter 5 , three phase synchronous motor coupled with dc shunt generator setup 1 , three phase synchronous motor coupled with dc shunt generator setup 2 , three phase synchronous motor coupled with dc shunt generator setup 3 , three phase synchronous motor coupled with dc shunt generator setup 4 , three phase veriable resistive load 1 , three phase veriable resistive load 2 , three phase veriable resistive load 3 , transmission line protection simulation kit 1 , transmission line protection simulation kit 2 , transmission line protection simulation kit 3 , transmission line protection simulation kit 4 , transmission line simulator 1 , transmission line simulator 2 , transmission line simulator 3 , undrground cable fault locator 1 , undrground cable fault locator 2 , undrground cable fault locator 3 , venturi flow measurement setup 1 , venturi flow measurement setup 2 , venturi flow measurement setup 3 , wattmeter 0. 5 1a, 150 300v low power factor , wattmeter 10 20 a ,150 300 600v unity power factor 1 , wattmeter 10 20 a ,150 300 600v unity power factor 2 , wattmeter 10 20 a ,150 300 600v unity power factor 3 , wattmeter 10 20 a ,150 300 600v unity power factor 4 , wattmeter 10 20 a //bid details2 / 127,150 300 600v unity power factor 5 , wattmeter 10 20 a ,150 300 600v unity power factor 6 , wattmeter 2. 5 5a , 150 300v unity power factor 1 , wattmeter 2. 5 5a , 150 300v unity power factor 2 , wattmeter 2. 5 5a , 150 300v unity power factor 3 , wattmeter 2. 5 5a , 150 300v unity power factor 4 , wattmeter 5 10 a ,150 300 600v unity power factor 1 , wattmet
Tender For corrigendum : 4 digit time interval digital timer meter as per the following technical specification: a) range auto ranging, fixed ranges b) temperature 50 deg c c)height :0.5 inches d)sensor supply : 12 v dc e)modes: contact type, stop watch , pickup time, drop off timer f) digits:4 digits g) size: 48 x 96mm