Tender For providing of custom bid for services - 9030c26a85 validation and maintenance services of ms ge make ultrasonicflowmeters and expert services of ms ge for moisture analyser installed at gujarat refinery
Tender For signal cable for fuji s portable ultrasonicflowmeter (5m x 2) p/n: zzp* tk7n7795c1 , silicone rubber sealant g40m, 100g pack make: shin-etsu
Tender For supply of electromagnetic water flowmeter with remote display and telemetry system size 2 inch , electromagnetic water flowmeter with remote display and telemetry system size 3 inch , electromagnetic water flowmeter with remote display and telemetry system size 4 inch , electromagnetic water flowmeter with remote display and telemetry system size 6 inch , telemetry system or rt unit or iot device with tow year cloud server gprs gsm sim with wifi based , ultrasonicflowmeter for open drain with v notch
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r
Tender For supply of seqstudio cartridge v2 2 boxes , seqstudio cathode buffer container cbc , integrated capillary protector icp , cathode buffer container reservoir septa 20 pack , 96 well plate septa 20 pack , microamp optical 96 well reaction plate , septa, 96 well 20 pk , hi di formamide 4 x 5 ml , bigdye terminator v3.1 cycle sequencing kit 100 reactions , bigdye xterminator kit 2ml each , exosap it 500 reactions ea , nuclease free water not depc treated , adhesive pcr plate seals 100 pc , genescan 600 liz size standard v2.0 800 rxns , 5 inch labeled or unlabeled primer pairs 10000 pmole , truemark msi assay , dpyd , human fwd primer ds , human rev primer ds , human fwd primer hplc , human rev primer hplc , oncomine myeloid research assay , oncomine focus assay each , oncomine comprehensive v3m combo kit , oncomine brca assay manual kit , ion xpress barcode adapters 1 96 , ion ampliseq lib kit plus , ngs reverse transcriptase kit , ion 510 ion 520 ion 530 kit chef 1 sequencing run per initialization , ion 530 chip kit , ion 520 chip kit , ion 510 ion 520 ion 530 kit chef 2 sequencing runs per initialization , ion 540 chef kit , ion 540 chip kit , ion 16s metagenomics kit , ion plus fragment library kit each , ion ampliseq microbiome health 48 rxn or pnl in 540 chip , alltype fastplex 11 loci kit , ion 520 ion 530 ext kit chef , oncomine cftna lung assay , tag sequencing bc set 1 24 , magmax cellfree total na isolation , ion xpress barcode adapters 1 16 kit , ion xpress barcode adapters 17 32 kit , ion xpress barcode adapters 33 48 kit , ion ampliseq library kit plus , microamp optical 96 well reaction plate , microamp fast optical 96 well reaction plate , microamp optical adhesive film , microamp adhesive film , microamp compression pad , ion library taqman quantitation kit , qubit dsdna quantification assay kits 500rxn , naoh 1n , tris hcl ph 8,1m , qubitrna br assay kits , qubit fluorometer system verification assay kits , qubit rna iq assay kits , qubit rna hs assay kits , qubit rna xr assay kits , magmax cell free dna isolation kit