Get complete information related to latest Meters Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Meters Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Meters Tenders.
Tender For supply of transmission measuring set (tms kit) complete with tone generator and db meter having 470-, 600-and 1120-ohm output impedance range, less than 2% distortion, more than 60 db degree of balance, transmission level of +10 dbm to -50 dbm in 10 db steps and +1 to -10 db continuous variable, accuracy +- 0.2 db, lcd digital panel meter, 3 & half digits display, rechargeable ni-mh battery. complete set with all connection lead & accessories. (connection cables, test leads, user manual, carrying case). [warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : tender for supply of electrical consumable and miscellaneous items for hurl sindri c - cable tie, lock type cut to open, colour-white, thickness-2.5mm, length-100mm, material nylon 66, pack size 100. cable tie, lock type cut to open, colour-white, thickness-2.5mm, length-200mm, material nylon 66, pack size 100. cable tie, lock type cut to open, colour-white, thickness-2.5mm, length 300mm, material nylon 66, pack size 100. electrical contact cleaner spray, quick dry, packing size for liquid(ml)-500ml galvanized zinc spray, finish type-bright silver, zinc-enriched coating to repair surface damage protection against corrosion, special feature-rust resistance, packing size for liquid(ml)-500ml. silica gel, colour of silica gel-blue, particle size -9 to 12 mm, air tight container for packing of silica gel-plastic. silicon sealant, physical state- viscous paste, appearance-translucent/ opaque, color-clear/black/white/gray, surface cure-5-10 min, packing size(ml)-300ml m-seal, shelf life 12 months, hardness 75-80, impact strength - 2.5 * 3kg / c * m setting time at 30 deg c min-60 min, working temp limit 80 deg. c component resin and hardness, packaging size-1 kg gap filling pu foam spray(puf seal), application fill the gap between wall & tray, conduit pipe and wire sealing, packing size for liquid(ml)-750ml. silicon sealant gun, feed type: push-fed gun, type: cordless-corded glue gun pvc tape, material pvc, adhesive-rubber bases adhesive, adhesive side- single side, temperature range (-40 degree c to 125 degree c), colour red, length-6.5 mtr, voltage resistance- upto 600v. pvc tape, material pvc, adhesive- rubber bases adhesive, adhesive side- single side, temperature range (-40 degree c to 125 degree c), colour yellow, length 6.5 mtr, voltage resistance-lipto 600v. pvc tape, material-pvc, adhesive- rubber bases adhesive, adhesive side-single side, temperature range (-40 degree c to 125 degree c), colour blue, length 6.5 mtr, voltage resistance-upto 600v pvc tape, material -pvc, adhesive rubber bases adhesive, adhesive side- single side, temperature range(-40 degree c to 125 degree c), colour-black, length 6.5 mtr, voltage resistance- upto 600v. pvc tape, material pvc, adhesive-rubber bases adhesive, adhesive side- single side, temperature range (-40 degree c to 125 degree c), colour green, length 6.5 mtr, voltage resistance upto goov ht-tape, self bonding electric tape, for high-voltage(upto 69kv), corona and ozone resistant, moisture and corrosion resistant, overload temperature 130 deg. c. roll size 9.15 meters. teflon tape, packing type-piece, elongation % 50-60, length of tape-9 mtr, application of colour tape white al foil tape, color-sever, type-aluminium foil tape 2 inch, cello tape type single sided, tape dispenser type-high bond, self adhesive, cello tape roll size-15 meters waste cotton doth emery paper, grit size grit 40-60, material emery, form-belt, bonding type-resin, coat type-open coat, suitable material mild steel, stainless steel. roll length-40 inch. emery paper, grit size-grit 220-400, material-emery, form-belt, bonding type-resin, coat type-open coat, suitable material mild steel, stainless steel roll length 280 mn trubble gum, strong glue trap, type- glue board, container type-sachet, protection against-rats titanium putty, 1 kg 1.5 sq.mm ring type lug, insulated type, rated voltage-upto 1100v, material copper, minimum pack of 200 2.5 sq.mm ring type lug, insulated type, rated voltage-upto 1100v, material copper, minimum pack of 100 4 sq.mm ring type lug, insulated type, rated voltage-upto 1100v, material-copper, minimum pack of 10 1.5 sq.mm pin type lug, insulated type, rated voltage-upto 1100v, material-copper, minimum pack of 200 2.5 sq.mm pin type lug, insulated type, rated voltage-upto 1100v, material copper, minimum pack of 20
Tender For 5hp non clog submersible sewage pump set, pumping capacity 72 cubic meter per hour at 8 mtrs head with speed 1450 rpm, complete with water protected seal for continuous operating 415v, 50 hz, supply with 10 mtrs, resin filled control cable and 10mtrs s.s chain with shackle and suitable fully automatic three phase starter control panel( dol/star delta starter which is suitable for that pump) along with single phase preventer with phase reversal sensing and dry run relay protection (current sensing type), thermistor relay and moisture control relay, analog /digital voltmeter , analog /digital ammeter , power on/trip and indication lamps, on/off switch and auto/manual mode switch (authorized dealership certificate to be enclosed while submitting offer, test certificate and warranty certificate to be submitted along with supply). make: ksb, kirloskar, mbh. karvel or similar [ warranty period: 30 months after the date of delivery] ]
Tender For repair/replacement of external electric supply distribution network with other connected items at malad, marve and kandivali under ge (n) santacruz, mumbai - supply, install, testing & commissioning pedestal cubical type double door lt bus bar chamber box of suitable size factory made modular construction fabricated out of 3 mm thick crca sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements front & back side opening system including rain shed, busbar chamber should be suitable for accomodating all aluminium bus bar strips (50mm x 10mm x 04 nos) & gi strip for earth fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom part, with fixing arrangement on pcc (1:3:6) type c-2 bed block with studs, bolts, nuts & washers, danger notice board with scull suitable for 415 volts or required size to be fixed on pannel including dismantling of old bus bar panel all as specified and directed by engr-in charge.notes:-(a) aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for phases and neutral - 01 set(b) mccb 4 pole , ics=100%icu- 25 ka, 415 volts, 100 amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 nos.(c) digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable ct of appropriate ratio.-01 no make- imp/automatic electrical(ae)/ l&t / havells/ meco(d) panel indicating lamp neon/led type (red ,yellow & blue) with lamp holders - 03 nos(e) panel instrumental wiring with frls suitable size but not less than 2.5 sqmm copper wire single core - 01 job(f) necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.make of mccb & mcb: larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 400 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:- larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 160 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 16 ka 100 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 250 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb all as specified and directed by engr-in-charge make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supplying, laying,connecting, testing & commissioning lt ug pvc insulated, heavy duty, 1100 v grade electric cable with aluminium conductor of size 16 sqmm x 4 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by engineer-in-charge of following sizes:-note : earthwork excavation, dwc
Tender For special repairs to lt panels and connected items at pyro, pinaka, nag mixture building, magazine area and ap building in hemrl, pune - taking out old serviceable/unserviceable lt panel/capacitor panel of any description or capacity keeping aside in safe custody for schedule of credit complete all as specified and directed, supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 03 nos, (c) mccb 4p, 125 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 200/5 - 04 nos, (e) control mcb c curve, sp, 6 to 32a, 10ka, c curve - 02 nos, (f) led phase indicator (r,y & b) - 01 set. (pyro sub stn), supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (c) mccb 4p, 315 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) mccb 4p, 250 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 nos (e) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 800/5 - 04 nos, (e) con
Tender For supply of e4963035 numerical relays 01-sg4950507001-numerical o_slash_c _and_ e_slash_f relay for incomer_slash_bc as per annexure-a it-001 _50_slash_51_slash_50n_slash_51n_slash_25_slash_50arc_ , 02-sg4950507010-numerical o_slash_c _and_ e_slash_f relay for trafo_slash_og as per annexure-a it-002 _50_slash_51_slash_50n_slash_51n_slash_50arc_ , 03- sg4950507028-numerical o_slash_c _and_ e_slash_f relay for plant feeder_slash_trf-vfd as per annexure-a it-003. , 04-sg4950507192-numerical o_slash_c _and_ e_slash_f relay for capacitor feeder as per annexure-a it-004. , 05-sg4950507044- numerical arc fault detection relay as per annexure-a it-005. , 06-sg4950507052-numerical bus diff relay as per annexure-a it-006. , 07- sg4950507060-numerical under voltage relay for bpt as per annexure-a it-007. , 08-sg4950507079- metrosil as per ann-a it-008. , 09-sg4950507087- stabilizing resistor as per ann-a it-009. , 10- sg4950507095-ethernet switches _16fo_ as per ann-a it-010. , 11-sg4950507109-ups as per ann-a it-011. , 12- sg4950507117-fo cable as per ann-a it-012. uom- meters , 13-sg4950507125-data concentrator panel as per ann-a it-013. , 14-sg4950507133-human machine interface _hmi_as per ann-a it-014. , 15-sg4950507141- relay parameterization device for switchboards as per ann-a it-015. , 16-sg4950507150-global positioning device as per ann-a it-016. , 17- sg4950507168-report printing device as per ann-a it- 017. , 18-sg4950507176-numerical ref relay as per ann-a it-018. , 19-sg4950507184-numerical trafo differential relay as per annexure-a it-019.
Tender For bid to ras bid to ras corrigendum : supply of vna with noise source , rf peak power meter , spectrum analyzer , hi precision digital multimeter , coax to wg adaptors , dc smr , dc mlat , dummy load , tool kit smr mlat
Tender For corrigendum : supply of repair and preventive maintenance of dg set ranchi oa - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva //bid details 2 / 35