Get complete information related to latest Petroleum Products Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Petroleum Products Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Petroleum Products Tenders.
Tender For corrigendum : supply of ring oiler assembly as per rcf drg. no. lw71241, alt. 'a' or latest for wheel set earthing equipment for lhb type coaches. note:- item to be procured from icf approved vendor only against uvam item ref.: 2300042 (sealing ring for axle box). [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of 2 point 5mfd ceiling fan capacitor , 3m plate make roma , 4m plate make roma , 6m plate make roma , 8m plate make roma , 12m plate make roma , 3m surface type pvc box make roma , 6m surface type pvc box make roma , 8m surface type pvc box make roma , 12m surface type pvc box make roma , 1m blanking platedummy make roma , 3pin 6a socket 2m make legrand , 616a 2in 1 socket 2m make legrand , 3pin 6a socket 2m make roma , 616a 2in 1 socket 2m make roma , 3pin 6a socket 2m make mk , 6a socket 2m make mk , 6 10a switch, 1m make roma , switch mk , switch legrand , 16 20a switch, 1m make mk , 16 20a switch, 1m make roma , 6pin 6a 16a ss combined with shutter and pvc boxmake anchor , 32a single pole c type mcb make legrand , 32a 2p c type mcb make legrand , 32a 3p c type mcb make legrand , 32a 4p c type mcb make legrand , 63a 4p c type mcb make legrand , 32a spn plug industrial socket and cap with metallic enclosure box suitable for ac make legrand , insulation tape , fischer plug suitable for 1 inch drywall screw , fischer plug , screw , 1ft 58w led cool white tube lightmake cromptonsyska equivalent , 2ft 14wled cool white tube light , cool white round led false ceiling light , 12w cool white round led surface mounting light , 18w cool white round led false ceiling light , 15w cool white round led surface light , 18w cool white round led surface light , 1m fan regulator make roma , 1m 4step 04fan regulator make legrand , 2m fan regulator makemk , exhaust ventilating fan makeorient model ventilator dx , telephone instrument , telephone instrument with caller id , 5inch pvc round sheet , thermostat solar water tank , 200w led cool white flood light , 56a 3pin plug top , 15a 3pin plug top , 9inch nylon selflocking cable tie , copper wire , dol starter make l and t bch electric , annealed copper telephone flexible unarmouredcable , aa duracell batteries , distilled water , handheld cardless microphones with 2mics in each and receiver with standard accessories , capacity empty oil barrel suitable for purchasing of diesel , rotary manual hand pump with dual direction , pvc casing pipe , pvc heavy duty conduit pipe , pvc casing heavy duty conduit pipe , mseal 90gm , steel clamp
Tender For auction sale of depot ferrous scrap - ms and cast steel scrap of diesel loco parts comprising of cylinder liners, cylinder head, fly wheels, gear, pin, connecting rod, piston, ring, valve, camshaft, turbo parts, screw coupling and fittings, axle boxes, shockers, knuckle adopter, gear case, stay plates, collar , housing, buffer assembly, ring, fasteners and other parts of sort and size with or without minor non ferrous attachment and residue oil and grease if any [ bin 28]
Tender For supply of various consumable & routine maintenance items for unit 1, 2 & 3 stage: i at wtps - teflon tape : size 1/2" width x 12mtr long, m seal fast curing epoxy compound, each packet contains 50 grams of resin base and 50 grams of hardener ( 1 kg box contains 10 packets)., hss hacksaw blade,size-1/2"bx12"lx0.025"thx18tpi., wire brush with wooden handle size 50x150x300 mm, hiffin diamond lapping compound hi finator grade 14-05-30 ( in plastic injection ; per injection 5gm), rustolene 500 ml/tin, holdtite liquid joint compound[500gms/pkg]4565250014, chrome leather hand gloves for welder. size: 16 inch (400 mm), metal set putty, bearing retainer, epoxy based fast curing cold metal repair compound., oil stop leak putty 114 gms. pack, descaler [biodegradable water scale cleaner], pen oil - (500 ml/tin) heavy duty rust penetrator, molykote 1000 (1kg/tin), rust removing spray wd-40 in aersole packing of high pressure valves ., h577 pipe sealant ( per tube 50 ml ), instant flange sealant & gasketing compund h510/510, molykote 1000 spray can (400ml/270gms/can), grinding disc (wheel) size 100x4x16 mm, mos 13750 high cut (a.36) ., resinoid cutting off wheel size 350x25.4x3 mm, a24 ., wel.lead glass black, white plain glass for welders hand screen, esab/iol make gas heating torch, oxygen gas hose pipe blue 08 mm, make esab/dura., acetylene gas hose pipe red 08 mm, make esab/dura., two stage two gauge oxygen gas pressure regulator - model no : dura 0-10 - esab make, two stage two gauge acetylene gas pressure regulator model : dura a-1.5 - esab make, wire brush size 12" with wooden handle, cutting nozzle size 3/64", cutting nozzle size 1/16", carborandum make emery cloth roll medium iss: 50-60 size: 50 mtrx25 mm, carborandum make emery cloth roll fine iss: 80-100, size: 50 mtrx25 mm, brand emery paper smooth fine size size 280 x 220 mm, flash back arrestor for cutting torch end mounted oxygen ., flash back arrestor for cutting torch end mounted da ., flash back arrestor for regulator mounted da cylinder., flash back arrestor for regulator mounted oxygen cylinder., gas cutting nozzles (1/32"), filler gauge set of 26 blades in mm 6" long, welding helmet, welding hand gloves leather size 14" for welding assly., welding cable copper conductor having single core high conductivity, suitable for 600 amp. of quality 70 sq.mm 999/0.3 mm as per is-9857/1990 vir insulated., hand screen armour, adhesive hylomer universal blue [100 gms/pkg/nos], pvc tap roll, oil paper size 2 x 2 x 1 mm thk, pvc hand gloves acid/alkali proof, hand gloves for heat resistance up to 350 deg. celsius: hand gloves with constructed from 100 percentage kevlar para-armid fiber with a cotton liner, size 10 (400mm). heat resistance for up to 350 deg. celsius temperature., blue matching tube camel student oil colour shade ultrasonic black-663 (in 20 ml tube), teflon tape : size 1/2" width x 12mtr long, m seal fast curing epoxy compound, each packet contains 50 grams of resin base and 50 grams of hardener ( 1 kg box contains 10 packets)., hss hacksaw blade,size-1/2"bx12"lx0.025"thx18tpi., wire brush with wooden handle size 50x150x300 mm, hiffin diamond lapping compound hi finator grade 14-05-30 ( in plastic injection ; per injection 5gm), rustolene 500 ml/tin, holdtite liquid joint compound[500gms/pkg]4565250014, chrome leather hand gloves for welder. size: 16 inch (400 mm), metal set putty, bearing retainer, epoxy based fast curing cold metal repair compound., oil stop leak putty 114 gms. pack, descaler [biodegradable water scale cleaner], pen oil - (500 ml/tin) heavy duty rust penetrator, molykote 1000 (1kg/tin), rust removing spray wd-40 in aersole packing of high pressure valves ., h577 pipe sealant ( per tube 50 ml ), instant flange sealant & gasketing compund h510/510, molykote 1000 spray can (400ml/270gms/can), grinding disc (wheel) size 100x4x16 mm, mos 13750 high cut (a.36) ., resinoid cutting off wheel size 350x25.4x3 mm, a24 ., wel.lead glass black, whi
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For repair/maintenance of diesel generator set with central panel and other connected items at zone 5 and 1(a,b,c) zone 1, 3 (a and b), zone 2 and zone 4 under ge (s) tezpur - maint and servicing of dg set 320-400 kva conopy type with amf panel (if installed ), through authorise service agency of oem , including replacment of defective/wornout parts with new spares such as filters, gaskets, v belts, engine oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of pol tank and radiator etc complete all as specified and directed.note:- 1. spares required for above maint will be measured and paid separately under relevent items of schedule. 2. all breakdown calls should be attended., all as per item no-1 above but for dg set of capacity 180-250 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 125-160 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 40-100 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 10-35 kva complete all as specified and directed, supply only fuel filter for 300-400 kva dg set, complete all as specified and directed, supply only fuel filter for 125-250 kva dg set,complete all as specified and directed complete all as specified and directed, supply only fuel filter for 10-100 kva dg set,complete all as specified and directed, supply only lub oil filter for 300-400 kva dg set,complete all as specified and directed, supply only lub oil filter for 125-250 kva dg set,complete all as specified and directed, supply only lub oil filter for 10-100 kva dg set,complete all as specified and directed, supply only air cleaner filter ( inner and outer ) for 300-400 kva dg set, complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 125-250 kva dg set,complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 10-100 kva dg set,complete all as specified and directed, supply only bypass filter for 300-400 kva dg set, complete all as specified and directed, supply only bypass filter for 125-250 kva dg set,complete all as specified and directed, supply only bypass filter for 10-100 kva dg set,complete all as specified and directed, supply only v belt for 300-400 kva dg set, complete all as specified and directed, supply only v belt for 125-250 kva dg set, complete all as specified and directed, supply only v belt for 10-100 kva dg set, complete all as specified and directed, supply only coolant for radiators complete all as specified and directed., supply only engine oil multi grade 15w40 complete all as specified and directed., s & f in repair display control panel ( base card) for 10 to 100 kva dg set complete all as specified and directed ., s & f in repair display control panel (base card) for 125 to 250 kva dg set complete all as specified and directed., s & f in repair display control panel (base card) for 300 to 400 kva dg set complete all as specified and directed., s & f in repair fuel actuator with o ring for 300 to 400 kva dg set complete all as specified and directed., s & f in repair key switch for 10 to 400kva dg set complete all as specified and directed., s & f in repair coolant temperature sensor (coolent control safety) for 10 to 400kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 10 to 100 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 125 to 250 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 300 to 400kva dg set complete all as specified and directed., s & f in rep
Tender For corrigendum : providing of repair maintenance of dg set hazaribag - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For corrigendum : providing of repair and maintenance of dg set under daltonganj - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva