Get complete information related to latest Wires And Cables Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Wires And Cables Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Wires And Cables Tenders.
Tender For supply of bullet camera cp plus5mp with installation , dome camera cp plus 5mp hd with installation , dvr 16 channel with 6tb hod , power spply 16ch , dvr 8 channel with 6 tb hdd cp plus , power supply 8 ch , ups 2kva , ups 1kva , tv 32 inch , co-axial cable , bnc plug , power connector , vga cable , rack
Tender For supply of qualification cleared display unit with environmental qualification test results1 , fully functional emdu hardware with accessories1 , associated cables, mating connectors and installation kits such as mounting arrangements with screws nuts etc1 , documents as listed in chapter 4 1 , training1
Tender For supply of 85 smart tv , 55 smart tv , retractable screen 15 ft 6 inch nontouch black , 4x4 matrix switcher , 4k premium series 20x camera , microphone conference controll system , gooseneck microphone chairman unit wired , gooseneck microphone delegate unit wired , wireless handheld microphone , power amplifier 200watts , wall mount speaker 50watts , pro audio dsp 12 channel , room appliance with touch tab w10t , 4k hdmi extender , speaker cable hdmi cable usb type a b , cable laying with pvc pipe and accessories , floor stand rack 18u 600x800 , installation commissioning and testing of technical building main conf room , speaker track pro 12x optical zoom , quadro speaker phone with extension mics , usb cable type ab and c , installation commissioning and testing of admin building conf room , hdmi cable usb cable type a and b , installation commissioning and testing of technical building small conf room ) /bid number : gem/2025/b/6757820 * /dated: 09-10-2025 & & / bid document 1 / 24
Tender For repair and annual maintenance of mini water supply installations in arsikere cmc limits - supplying and laying (dwc) hdpe pipe 32mm dia, replacement of tpn 40a mcb, supplying & fixing ammeter 0to 30ammeter, repair and re-condition of pump set of above 10 h.p to 15 h.p/12 to 20 stage capacity which includes replacement of all items, fixing, transportation and labour charges, for details, refer technical specifications and schedule of requirements in the tender document., repair and re-condition of pump set of above 5 h.p to 10 h.p/8 to 14 stage capacity which includes replacement of all items, fixing, transportation and labour charges, for details, refer technical specifications and schedule of requirements in the tender document., supplying and fixing porcelain fuse with cut out 125 amps, replacement of tata class b heavy duty 2inch gi collar, replacement of 6h.p 10 stage pump set, re-winding and re-condition of submersible motor of above 10 h.p to 15 h.p capacity which includes replacement of all items, fixing, transportation and labour charges, for details, refer technical specifications and schedule of requirements in the tender document., re-winding and re-condition of submersible motor of above 5 h.p to 10 h.p capacity which includes replacement of all items, fixing, transportation and labour charges, for details, refer technical specifications and schedule of requirements in the tender document., labour charges for lifting and dropping pump sets, digging of trench including labour charge, supplying and replacement of lt ug cable 4 core 10 sq mm, supplying and replacement of submersible flat pvc copper cable 3c x 6 sq mm, starter repair which includes replacement of spare parts such as contactors, push buttons, overload relay, no volt coil etc.., with complete wiring, replacement of starter box, supplying & replacement of push button switches of the starter, supplying and replacement of pcb board in the single phase preventer, supplying and replacement of no-volt coil of the contactor, supplying and replacement of contactor suitable to operate upto 20 h.p capacity motor, supplying & fixing single phase preventer suitable for motor upto 20 h.p capacities, supplying & fixing voltmeter 0 to 600 volts, supplying and fixing porcelain fuse with cut out 63 amps, supplying and fixing porcelain fuse with cut out 32 amps, supplying and fixing porcelain fuse with cut out 16 amps, supplying of 8inch bore cap for mws, flushing of existing borewells, re drilling of existing bore wells, replacement of tata b chass heavy duty 2inch gi pipe, replacement of indicators, replacement of starter suitable for pump set upto 15 h.p capacities, replacement of starter suitable for pump set upto 10 hp capacities, replacement of 12.5 h.p 20 stage pump set, replacement of 10 h.p 14 stage pump set, replacement of 10 h.p 12 stage pump set, replacement of 7.5 h.p 12 stage pump set, replacement of 7.5 h.p 10 stage pump set, replacement of 6 h.p 8 stage pump set, replacement of rotary selector switch, labour charges for lifting of failed pump set , labour charges for lifting of struck pump set, threading of g.i pipes, replacement of shunt capacitor upto 10 kvar capacity, replacement of wooden panel board, replacement of over head service mains upto 10 sq mm capacity aluminium wires
Tender For rmo electrical & mechanical services at mso building, ip estate, new delhi. (providing various electrical accessories at ground floor barrack, horticulture nursery and parking area in mso building, new delhi) - wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc as required.a) group c, rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm. frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required.a) group c, wiring for circuit/ submain wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as requireda) 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire, b) 2 x 4 sq. mm + 1 x 4 sq. mm earth wire, supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required.a) 3 x 1.5 sq. mm, b) 3 x 4 sq. mm, supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.a) 20 mm, b) 25 mm, supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.a) 5/6 amps switch, b) 15/16 amp switch, c) 3 pin 5/6 amp socket outlet, d) 6 pin 15/16 amp socket outlet, supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required.a) 6 module (200mmx75mm), b) 12 module (200mmx150mm), supplying and fixing following modular base & cover plate on existing modular metal boxes etc. as required.a) 3 module, b) 6 module, c) 12 module, supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator)a) 12 way, double door, supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, tpn mccb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 250 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting mccbs (but without mccbs and incomer ) as required . (note : vertical type mccb tpdb is normally used where 3 phase outlets are required.)a) 8 way (4 + 24), double door, supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "c" curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.a) single pole, supplying and fixing following rating, double pole, 240 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required.a) 63 amps, supplying and fixing dp sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "c" curve dp mcb complete with connections, testing and commissioning etc. as required., supplying and fixing of 3 mm thickness phenolic laminated hylam sheet of assorted sizes on existing switch box along with cadmium plated screws etc as required., supplying, installation, testing & commissioning of led surface mounted batten light, powder coated die cast aluminum /polycarbonate body with built in driver ( 750ma),operating voltage ac 100-240 volt, freq 50/60 hz