Get complete information related to latest Wires And Cables Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Wires And Cables Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Wires And Cables Tenders.
Tender For restoration of rain damages on link road salli to konal road km 0/00 to 2/250 (s.h:- construction of r/wall with wire erste and c.c pusta al rd 0/520 to 0/525).
Tender For restoration of rain damages on link road salli to konal road km 0/00 to 2/250 (s.h:- construction of r/wall with wire crate and c.c pusta al rd 0/526 to 0/530).
Tender For rmo electrical & mechanical services at mso building, ip estate, new delhi. (providing various electrical accessories at ground floor barrack, horticulture nursery and parking area in mso building, new delhi) - wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc as required.a) group c, rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm. frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required.a) group c, wiring for circuit/ submain wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as requireda) 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire, b) 2 x 4 sq. mm + 1 x 4 sq. mm earth wire, supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required.a) 3 x 1.5 sq. mm, b) 3 x 4 sq. mm, supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.a) 20 mm, b) 25 mm, supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.a) 5/6 amps switch, b) 15/16 amp switch, c) 3 pin 5/6 amp socket outlet, d) 6 pin 15/16 amp socket outlet, supplying and fixing following size/ modules, gi box along with modular base & cover plate for modular switches in recess etc as required.a) 6 module (200mmx75mm), b) 12 module (200mmx150mm), supplying and fixing following modular base & cover plate on existing modular metal boxes etc. as required.a) 3 module, b) 6 module, c) 12 module, supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator)a) 12 way, double door, supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, tpn mccb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 250 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting mccbs (but without mccbs and incomer ) as required . (note : vertical type mccb tpdb is normally used where 3 phase outlets are required.)a) 8 way (4 + 24), double door, supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "c" curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.a) single pole, supplying and fixing following rating, double pole, 240 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required.a) 63 amps, supplying and fixing dp sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "c" curve dp mcb complete with connections, testing and commissioning etc. as required., supplying and fixing of 3 mm thickness phenolic laminated hylam sheet of assorted sizes on existing switch box along with cadmium plated screws etc as required., supplying, installation, testing & commissioning of led surface mounted batten light, powder coated die cast aluminum /polycarbonate body with built in driver ( 750ma),operating voltage ac 100-240 volt, freq 50/60 hz
Tender For repair and restoration of rain damages link road bari mohalla deoli to connect ghanari nangal jarialan in gp deoli km 000 to 1800 sh co wire crate wall and filling in km 100 to 1035 under pdna 2023
Tender For tender for supply of sitc of ip epabx system and accessories with semiskilled manpower deployment d d - sitc (supply installation testing commissioning ) of dual server gateway based ip pbx system in raid 1 storage configuration (1set equals 2 nos) , sitc of management platform inclusive of management software with liscence (1set equals 2 nos) , itc of executive ip phones with 2 way speaker phone (installation , testing and commissioning) , supply of executive ip phones with 2 way speaker phone , itc of poe based ip phones (installation , testing and commissioning) , supply of poe based ip phones , sitc of corded analog phone with cli , sitc of pc based ip operator console in raid 1 storage configuration with liscence version of software(latest) , sitc of laptop based ip operator console with liscence version os and ms office (latest) , sitc of 24 port l2 plus managed poe plus switch with fully loaded sfp modules single mode transceiver. , sitc of 16 port l2 plus managed poe plus switch with fully loaded sfp modules single mode transceiver. , sitc of 8 port l2 plus managed poe plus switch with fully loaded sfp modules single mode transceiver. , supply of cat 6a cable industrial grade including capping , casing , conduiting fasteners with all materials. , itc of cat-6a cable (for boq item 19) industrial grade including capping , casing , conduiting fasteners with all materials at various locations within aai premises.payment on actual per meter measurement basis. , supply of cat 6a utp patch cord 3 meter each. , supply of 3 core power cable 2.5mm each core. , itc of 3 core power cable 2.5mm each core.payment for laying will be on actual per meter measurement basis only. , sitc of intermediate distribution frame idf for 100 pairs. , sitc of intermediate distribution frame idf for 20 pairs. , sitc of intermediate distribution frame idf for 200 pairs. , sitc of intermediate distribution frame idf for 400 pairs. , surge protection device for idf krone type (10 pair in each krone). , supply of 0.5mm , 50 pair copper cable (armourd). , supply of 24 core core armoured single mode ofc cable. , itc (including laying) of 50 pair copper cable (0.5mm) and 24 core armoured single mode ofc cable (including capping , casing , conduiting fasteners with all materials) with hdd laying (hdd min depth 1.65 meter)payment on actual per meter measurement basis , supply of 0.5 mm , 20 pairs telephone cable. , laying of 0.5 mm , 20 pairs telephone cable. payment for laying will be on actual per meter measurement basis only. , sitc of rack mounted ups 2 kva line interactive , 30 min backup for network switches. , sitc of rack mounted ups 1 kva line interactive , 30 min backup for network switches. , sitc of fully loaded 42u rack for epabx server its accessories with cable manager 2 pdu. , sitc of rack mounted ups 5 kva online , 60 min backup for epabx servers and gateways (1set equals 2 nos) , electrical distribution system (with industrial grade mcb) as per ip epabx system requirement (min. 32 amp.) with rccb. , sitc of 3 core power cable 6 sq. mm each core. , rack mounted load transfer switch (auto changeover switch for ups output).+c37 , surge protection device spd lan. , power surge protection device spd for 5 kva ups single phase in - single phase out. , earthing system (copper strip 25mm x 3mm , 150 meters) and 6 sqmm , 100 m cable for internal distribution. , liu 24 core with pig tail (testing of fiber termination). , rj 45 patch panel 24 port. , 12u rack for poe switches & its accessories with cable manager & pdu. , io boxes with dual rj45 ports with gang box and cover. , io boxes rj45 ports with gang box and cover. , io boxes with dual rj11 ports with gang box and cover. , integration charges of all the eqpt systems associated with ip epabx mentioned in this bill of material with existing operational equipment with operational and technical training charges for 5 personnel for 3 day including all cost components. , gpr work (ground pene