Get complete information related to latest Ac Unit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ac Unit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ac Unit Tenders.
Tender For supply of ntc sensor, 5k @25 deg-c, operating temperature 40 deg.c to 140deg.c, with two metre teflon wire, suitable for micro processor controllers of lhb rmpu acunit confirming to rdso spec-rdsope/spec/ac/0139-2009 (rev 1), make - us sensors (littlefuse)/ amphenol/ vishay/ thermosen/ betatherm/ sysaid/ jr sensing and electronics technology/ polo/ semitic only. (to be procured from rdso approved sources of microprocessor controller or their authorized dealers (uvam item code- 3100369)). [ warranty period: 30 months after the date of delivery ] ]
Tender For motor suitable for condenser, 0.15kw, supply 415v ac +/- 10%, 3-phase, 0.7amps, 63 frames, rpm-1350, star connection, reference is: 325, frequency 50hz for roof mounted packaged acunitelectric locomotives as per rdso spec. no. rdso/2007/el/spec/0055, rev. - 2, or latest if any. [ warrantyperiod: 30 months after the date of delivery ] ]
Tender For tender for empanelment of contractors& architect/consultant in various financial category. - architect/consultant ,civil construction/repairing work including plumbing , furnishing work including repairing of furniture ,air-conditioning work including operation/ maintenance services of standalone (window /split / cassette/ tower) air-conditioning units
Tender For corrigendum : providing comprehensive maintenance and monthly servicing to split and tower type a.c. units of various makes and capacities located in city civil court, secunderabad for the year 2026-27
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split acunits complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split acunits complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split acunits complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split acunits complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For corrigendum : supply of sitc of ceiling mounted ductable type split acunits as per clause 16 schedule of quantities sl no 1 of atc , dummy line item 2 sellers no need to quote for this line item , dummy line item 3 sellers no need to quote for this line item , dummy line 4 item sellers no need to quote for this line item , dummy line item 5 sellers no need to quote for this line item
Tender For corrigendum : annual maintenance contract for inbuilt air conditioning system in komatsu make wa600 6r payloader for a period of 1 year, working at bina project. (work to be carried out at ncl site).