Get complete information related to latest Acoustic Insulation Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Acoustic Insulation Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Acoustic Insulation Tenders.
Tender For supply of different type material against head deposit of electricity distribution sub division- sandila hardoi. - holding clamp made of ms flat 50x6 mm.fro st pole cross arm, holding clamp made of ms flat 50x6 mm.fro pcc pole cross arm, 11 kv f- clamp made of ms flat 50x8 mm. with nut bolt, top dropper t-off holding clamp ms flat 50x6 mm. st pole, top dropper t-off holding clamp ms flat 50x6 mm. pcc pole, lt clamp ms flat 50x6 mm. for st pole, lt clamp ms flat 50x6 mm. for pcc pole, lt shackle insulator 3x3 12, nut bolt for shackle insulator 12x150 mm., stay clamp
Tender For tn-11174 supply of spares for esp of unit 1 to 7 at kstps, kota. - outer arm for emitting rapping sys., outer arm for collecting rapping, inner arm of esp for collecting, u" guide for collecting electrodes with inner distance 44.5 mm for stage- 1 to 2, u" guide for collecting electrodes with inner distance 54.0 mm for stage- 3 to 5, spiral emitting electrode 47 turns, wire, 2.7mm (mat for wire uhb-904 l, mat for hook- tube carbon steel), emitting electrode 2.7 mm wire dia, 52 turns spiral type with hook (material for wire uhb-904 l, material for hook tube carbon steel), sleeve for shock bar of esp with ht bolt & nut (m 20x75), sleeve bearing for emitting drive, set ring for cerm, plain bearing, shaft insulator, g d screen sheet, pin for pin wheel i/ii, shaft-i for cerm d50, l-4790mm, shaft-ii for cerm d50, l-4985mm, emitting rapping shaft 40mm dia, 2500mm length, shaft-iii for eerm d50 l-3350mm, emitting drive shaft for stage 3, dia-40mm, l-3306mm, key size 12x8x70, emitting drive shaft iii, dia-40mm, l-2995mm, ms packing shim, 100 mm x 70 mm, thickness 6mm, pin wheel-i (big), pin wheel-ii (small), shock pad for shock bar for esp, shaft sleeve, od 50mm,id 40.5 mm,length 120mm, shaft-i for eerm, d-50 mm, l-4320 mm stage-ii, shaft-ii for eerm, d-50 mm, l-4250 mm stage-ii, emitting drive shaft -ii, d-40 mm, l-3020 mm stage- ii, end shaft for cerm with key slots, d-50 mm, l-790 mm stage-iii to v, shaft-i for eerm, d-50 mm, l- 3120 mm stage iii to v, shaft-ii for eerm, d-50 mm, l- 3290 mm stage iii to v, top coupling for emitting drive shaft-i , d- 40 mm, shock bar guide (f) for stg.-i , 6 slot, shock bar guide (r) for stg.-i , 4 slot, shock bar guide (r) for stg.-ii , 4 slot, deflection plate ms having size 495x230x2.5mm as per drwing enclosed
Tender For 10/edc(s)/2025-26 - part-a (material), following materials supplied by the contractor :-, stone pad., lt clamp with nut & bolts., earth wire clamp with nut & bolts., clamp for top/t-off/dropper., suspension clamp., dead end clamp., eye hook., eye hook clamp., x-arm holding clamp., red oxide paint., alluminium paint., f-bracket., guarding angle., guarding angle clamp., shackle insulator., distribution box 3 phase with clamp., stay loop insulator, bolts, nuts & washers all sizes., l.t. connector (pearcing)., safe carriage/cartage of following items from store centre, sultanpur to work site including loading, unloading and proper stacking (distance within 0-50 km.), safe carriage of stp 11 mtr., safe carriage of pcc pole 8.5 mtr. long., safe carriage of acsr weasel conductor/dog conductor., safe carriage of 11 kv xlpe cable al. 3x120/3x70 sq.mm., safe carriage of lt xlpe cable abc 1 phase/3 phase., safe carriage of meter qubical., safe carriage of ct/pt combinud unit., safe carriage of t/f 25 kva., safe carriage of t/f 63 kva., safe carriage of t/f 100 kva., safe carriage of t/f 250 kva., safe carriage of t/f 400 kva., safe carriage of other line materials., dragging of stp from site to pit point., dragging of pcc pole from site to pit point., fabrication & errection of single pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of single pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., grouting of structure by digging od pit 1.83 mtr. deep for 11 mtr stp/8.5 mtr pcc pole foundation is provided with help of steel or wooden formers, groutung with 1:4:5 ratio cement, sand & first class brick ballast 0.285 cu mtr for 11 mtr stp/8.5 mtr pcc pole plinthing 0.3 mtr above g/l and proper plastering as per respo norms., earthing of 11 mtr stp/8.5 mtr pcc pole as per respo norms., stay complete., laying stringing & sagging of new acsr weasel conductor/dog conductor including binding jumpering etc., digging of trench & laying of cable 11 kv xlpe cable 3x120/3x70 sq.mm including sands & brick., hanging hosting & clamping and g.i. pipe channel nut & bolts 3x120/3x70 sq mm xlpe 11 kv cable (cost of all accessories will be borne by contractor) as per resspo norms., installation and fixing of heat shrinkable type 11 kv cable joiting kit 3x120/3x70 sq mm xlpe cable box as per norms., high pressure testing after completion of laying of 11 kv xlpe cable, fixing of joints & termination. (testing equipment shall be arranged by the contractor)., making cable jointing kit i/d & o/d 3x120/3x70 sq.mm., installation of meter qubical., installation of ct/pt combinud unit., route cable marker with size 3x1.5 feet stone for underground cable at every 100 mtr from initial point with notice "11 kv u/g line" painted on it (all the material, manpower and t&p will be arranged by the contractor at his own cost)., road restoration charges for pucca road crossing., road restoration charges for footpath side., laying stringing & sagging of lt xlpe cable abc 3x120+1x95+1x16/3x50+1x35+1x16/1x25+ 1x16 sq.mm., erection and mounting of 25 kva t/f., erection and mounting of 63 kva t/f., erection and mounting of 100 kva t/f., providing and installation of smc box for 25 kva to 100 kva., installation of 250/400 kva t/f on plinth., construction of plinth for 250/400 kva t/f including of all material as per respo norms., fencing work suitable of 250/400 kva t/f plinth of size 15x12x8 and angles of suitable size should be grouted on all 04 corners and 01 side for gate.
Tender For runningcontractfordepositworksunderedd-lambhua,sultanpur. - part-a (material), following materials supplied by the contractor :-, stone pad., lt clamp with nut & bolts., earth wire clamp with nut & bolts., clamp for top/t-off/dropper., suspension clamp., dead end clamp., eye hook., eye hook clamp., x-arm holding clamp., red oxide paint., alluminium paint., f-bracket., guarding angle., guarding angle clamp., shackle insulator., distribution box 3 phase with clamp., stay loop insulator, bolts, nuts & washers all sizes., l.t. connector (pearcing)., safe carriage/cartage of following items from store centre, sultanpur to work site including loading, unloading and proper stacking (distance within 0-50 km.), safe carriage of stp 11 mtr., safe carriage of pcc pole 8.5 mtr. long., safe carriage of acsr weasel conductor/dog conductor., safe carriage of 11 kv xlpe cable al. 3x120/3x70 sq.mm., safe carriage of lt xlpe cable abc 1 phase/3 phase., safe carriage of meter qubical., safe carriage of ct/pt combinud unit., safe carriage of t/f 25 kva., safe carriage of t/f 63 kva., safe carriage of t/f 100 kva., safe carriage of t/f 250 kva., safe carriage of t/f 400 kva., safe carriage of other line materials., dragging of stp from site to pit point., dragging of pcc pole from site to pit point., fabrication & errection of single pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of single pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., grouting of structure by digging od pit 1.83 mtr. deep for 11 mtr stp/8.5 mtr pcc pole foundation is provided with help of steel or wooden formers, groutung with 1:4:5 ratio cement, sand & first class brick ballast 0.285 cu mtr for 11 mtr stp/8.5 mtr pcc pole plinthing 0.3 mtr above g/l and proper plastering as per respo norms., earthing of 11 mtr stp/8.5 mtr pcc pole as per respo norms., stay complete., laying stringing & sagging of new acsr weasel conductor/dog conductor including binding jumpering etc., digging of trench & laying of cable 11 kv xlpe cable 3x120/3x70 sq.mm including sands & brick., hanging hosting & clamping and g.i. pipe channel nut & bolts 3x120/3x70 sq mm xlpe 11 kv cable (cost of all accessories will be borne by contractor) as per resspo norms., installation and fixing of heat shrinkable type 11 kv cable joiting kit 3x120/3x70 sq mm xlpe cable box as per norms., high pressure testing after completion of laying of 11 kv xlpe cable, fixing of joints & termination. (testing equipment shall be arranged by the contractor)., making cable jointing kit i/d & o/d 3x120/3x70 sq.mm., installation of meter qubical., installation of ct/pt combinud unit., route cable marker with size 3x1.5 feet stone for underground cable at every 100 mtr from initial point with notice "11 kv u/g line" painted on it (all the material, manpower and t&p will be arranged by the contractor at his own cost)., road restoration charges for pucca road crossing., road restoration charges for footpath side., laying stringing & sagging of lt xlpe cable abc 3x120+1x95+1x16/3x50+1x35+1x16/1x25+ 1x16 sq.mm., erection and mounting of 25 kva t/f., erection and mounting of 63 kva t/f., erection and mounting of 100 kva t/f., providing and installation of smc box for 25 kva to 100 kva., installation of 250/400 kva t/f on plinth., construction of plinth for 250/400 kva t/f including of all material as per respo norms., fencing work suitable of 250/400 kva t/f plinth of size 15x12x8 and angles of suitable size should be grouted
Tender For runningcontractfordepositworksunderedd-baldirai,sultanpur. - part-a (material), following materials supplied by the contractor :-, stone pad., lt clamp with nut & bolts., earth wire clamp with nut & bolts., clamp for top/t-off/dropper., suspension clamp., dead end clamp., eye hook., eye hook clamp., x-arm holding clamp., red oxide paint., alluminium paint., f-bracket., guarding angle., guarding angle clamp., shackle insulator., distribution box 3 phase with clamp., stay loop insulator, bolts, nuts & washers all sizes., l.t. connector (pearcing)., safe carriage/cartage of following items from store centre, sultanpur to work site including loading, unloading and proper stacking (distance within 0-50 km.), safe carriage of stp 11 mtr., safe carriage of pcc pole 8.5 mtr. long., safe carriage of acsr weasel conductor/dog conductor., safe carriage of 11 kv xlpe cable al. 3x120/3x70 sq.mm., safe carriage of lt xlpe cable abc 1 phase/3 phase., safe carriage of meter qubical., safe carriage of ct/pt combinud unit., safe carriage of t/f 25 kva., safe carriage of t/f 63 kva., safe carriage of t/f 100 kva., safe carriage of t/f 250 kva., safe carriage of t/f 400 kva., safe carriage of other line materials., dragging of stp from site to pit point., dragging of pcc pole from site to pit point., fabrication & errection of single pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of single pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., grouting of structure by digging od pit 1.83 mtr. deep for 11 mtr stp/8.5 mtr pcc pole foundation is provided with help of steel or wooden formers, groutung with 1:4:5 ratio cement, sand & first class brick ballast 0.285 cu mtr for 11 mtr stp/8.5 mtr pcc pole plinthing 0.3 mtr above g/l and proper plastering as per respo norms., earthing of 11 mtr stp/8.5 mtr pcc pole as per respo norms., stay complete., laying stringing & sagging of new acsr weasel conductor/dog conductor including binding jumpering etc., digging of trench & laying of cable 11 kv xlpe cable 3x120/3x70 sq.mm including sands & brick., hanging hosting & clamping and g.i. pipe channel nut & bolts 3x120/3x70 sq mm xlpe 11 kv cable (cost of all accessories will be borne by contractor) as per resspo norms., installation and fixing of heat shrinkable type 11 kv cable joiting kit 3x120/3x70 sq mm xlpe cable box as per norms., high pressure testing after completion of laying of 11 kv xlpe cable, fixing of joints & termination. (testing equipment shall be arranged by the contractor)., making cable jointing kit i/d & o/d 3x120/3x70 sq.mm., installation of meter qubical., installation of ct/pt combinud unit., route cable marker with size 3x1.5 feet stone for underground cable at every 100 mtr from initial point with notice "11 kv u/g line" painted on it (all the material, manpower and t&p will be arranged by the contractor at his own cost)., road restoration charges for pucca road crossing., road restoration charges for footpath side., laying stringing & sagging of lt xlpe cable abc 3x120+1x95+1x16/3x50+1x35+1x16/1x25+ 1x16 sq.mm., erection and mounting of 25 kva t/f., erection and mounting of 63 kva t/f., erection and mounting of 100 kva t/f., providing and installation of smc box for 25 kva to 100 kva., installation of 250/400 kva t/f on plinth., construction of plinth for 250/400 kva t/f including of all material as per respo norms., fencing work suitable of 250/400 kva t/f plinth of size 15x12x8 and angles of suitable size should be grouted
Tender For runningcontractfordepositworksunderedd-jaisinghpur,sultanpur. - part-a (material), following materials supplied by the contractor :-, stone pad., lt clamp with nut & bolts., earth wire clamp with nut & bolts., clamp for top/t-off/dropper., suspension clamp., dead end clamp., eye hook., eye hook clamp., x-arm holding clamp., red oxide paint., alluminium paint., f-bracket., guarding angle., guarding angle clamp., shackle insulator., distribution box 3 phase with clamp., stay loop insulator, bolts, nuts & washers all sizes., l.t. connector (pearcing)., safe carriage/cartage of following items from store centre, sultanpur to work site including loading, unloading and proper stacking (distance within 0-50 km.), safe carriage of stp 11 mtr., safe carriage of pcc pole 8.5 mtr. long., safe carriage of acsr weasel conductor/dog conductor., safe carriage of 11 kv xlpe cable al. 3x120/3x70 sq.mm., safe carriage of lt xlpe cable abc 1 phase/3 phase., safe carriage of meter qubical., safe carriage of ct/pt combinud unit., safe carriage of t/f 25 kva., safe carriage of t/f 63 kva., safe carriage of t/f 100 kva., safe carriage of t/f 250 kva., safe carriage of t/f 400 kva., safe carriage of other line materials., dragging of stp from site to pit point., dragging of pcc pole from site to pit point., fabrication & errection of single pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of single pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., grouting of structure by digging od pit 1.83 mtr. deep for 11 mtr stp/8.5 mtr pcc pole foundation is provided with help of steel or wooden formers, groutung with 1:4:5 ratio cement, sand & first class brick ballast 0.285 cu mtr for 11 mtr stp/8.5 mtr pcc pole plinthing 0.3 mtr above g/l and proper plastering as per respo norms., earthing of 11 mtr stp/8.5 mtr pcc pole as per respo norms., stay complete., laying stringing & sagging of new acsr weasel conductor/dog conductor including binding jumpering etc., digging of trench & laying of cable 11 kv xlpe cable 3x120/3x70 sq.mm including sands & brick., hanging hosting & clamping and g.i. pipe channel nut & bolts 3x120/3x70 sq mm xlpe 11 kv cable (cost of all accessories will be borne by contractor) as per resspo norms., installation and fixing of heat shrinkable type 11 kv cable joiting kit 3x120/3x70 sq mm xlpe cable box as per norms., high pressure testing after completion of laying of 11 kv xlpe cable, fixing of joints & termination. (testing equipment shall be arranged by the contractor)., making cable jointing kit i/d & o/d 3x120/3x70 sq.mm., installation of meter qubical., installation of ct/pt combinud unit., route cable marker with size 3x1.5 feet stone for underground cable at every 100 mtr from initial point with notice "11 kv u/g line" painted on it (all the material, manpower and t&p will be arranged by the contractor at his own cost)., road restoration charges for pucca road crossing., road restoration charges for footpath side., laying stringing & sagging of lt xlpe cable abc 3x120+1x95+1x16/3x50+1x35+1x16/1x25+ 1x16 sq.mm., erection and mounting of 25 kva t/f., erection and mounting of 63 kva t/f., erection and mounting of 100 kva t/f., providing and installation of smc box for 25 kva to 100 kva., installation of 250/400 kva t/f on plinth., construction of plinth for 250/400 kva t/f including of all material as per respo norms., fencing work suitable of 250/400 kva t/f plinth of size 15x12x8 and angles of suitable size should be grou
Tender For runningcontractfordepositworksunderedd,sultanpur. - part-a (material), following materials supplied by the contractor :-, stone pad., lt clamp with nut & bolts., earth wire clamp with nut & bolts., clamp for top/t-off/dropper., suspension clamp., dead end clamp., eye hook., eye hook clamp., x-arm holding clamp., red oxide paint., alluminium paint., f-bracket., guarding angle., guarding angle clamp., shackle insulator., distribution box 3 phase with clamp., stay loop insulator, bolts, nuts & washers all sizes., l.t. connector (pearcing)., safe carriage/cartage of following items from store centre, sultanpur to work site including loading, unloading and proper stacking (distance within 0-50 km.), safe carriage of stp 11 mtr., safe carriage of pcc pole 8.5 mtr. long., safe carriage of acsr weasel conductor/dog conductor., safe carriage of 11 kv xlpe cable al. 3x120/3x70 sq.mm., safe carriage of lt xlpe cable abc 1 phase/3 phase., safe carriage of meter qubical., safe carriage of ct/pt combinud unit., safe carriage of t/f 25 kva., safe carriage of t/f 63 kva., safe carriage of t/f 100 kva., safe carriage of t/f 250 kva., safe carriage of t/f 400 kva., safe carriage of other line materials., dragging of stp from site to pit point., dragging of pcc pole from site to pit point., fabrication & errection of single pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of single pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., grouting of structure by digging od pit 1.83 mtr. deep for 11 mtr stp/8.5 mtr pcc pole foundation is provided with help of steel or wooden formers, groutung with 1:4:5 ratio cement, sand & first class brick ballast 0.285 cu mtr for 11 mtr stp/8.5 mtr pcc pole plinthing 0.3 mtr above g/l and proper plastering as per respo norms., earthing of 11 mtr stp/8.5 mtr pcc pole as per respo norms., stay complete., laying stringing & sagging of new acsr weasel conductor/dog conductor including binding jumpering etc., digging of trench & laying of cable 11 kv xlpe cable 3x120/3x70 sq.mm including sands & brick., hanging hosting & clamping and g.i. pipe channel nut & bolts 3x120/3x70 sq mm xlpe 11 kv cable (cost of all accessories will be borne by contractor) as per resspo norms., installation and fixing of heat shrinkable type 11 kv cable joiting kit 3x120/3x70 sq mm xlpe cable box as per norms., high pressure testing after completion of laying of 11 kv xlpe cable, fixing of joints & termination. (testing equipment shall be arranged by the contractor)., making cable jointing kit i/d & o/d 3x120/3x70 sq.mm., installation of meter qubical., installation of ct/pt combinud unit., route cable marker with size 3x1.5 feet stone for underground cable at every 100 mtr from initial point with notice "11 kv u/g line" painted on it (all the material, manpower and t&p will be arranged by the contractor at his own cost)., road restoration charges for pucca road crossing., road restoration charges for footpath side., laying stringing & sagging of lt xlpe cable abc 3x120+1x95+1x16/3x50+1x35+1x16/1x25+ 1x16 sq.mm., erection and mounting of 25 kva t/f., erection and mounting of 63 kva t/f., erection and mounting of 100 kva t/f., providing and installation of smc box for 25 kva to 100 kva., installation of 250/400 kva t/f on plinth., construction of plinth for 250/400 kva t/f including of all material as per respo norms., fencing work suitable of 250/400 kva t/f plinth of size 15x12x8 and angles of suitable size should be grouted on all 0
Tender For m and r work under edd- rania -- loading 8.5 m long pcc pole from electricity storage centre jainpur on own vehicle and taking it to work site and unloading it safely through unpaved road. a loading 11 m stp pole from electricity storage centre jainpur on own vehicle and taking it to work site and unloading it safely through unpaved road. a transport of electric line material like conductor, clamp, nut-bolt wire, lt cable, stonepad, station set, xlpe, abc etc. to the specified place by own vehicle for an estimated distance of 75 km through unpaved road. a digging pit at the place of broken/damaged poles and installing pcc poles by tying all accessories like cross arm, disc, pin insulator etc. and fitting earthing rod. a tying all accessories as per requirement in the long span in the middle of the already constructed line. the work of re-energizing by installing additional pcc/stp poles as per the prescribed standard/specification of response link. a the work of re-energizing by installing additional pcc/stp poles as per the prescribed standard/specification of response link while tying all the accessories as per requirement in the middle long span of the already constructed line. a installation of new section double pole in place of broken/damaged double pole. a grouting work of pcc/stp poles as per respo standard. supplying cement, ballast, gravel in the ratio of 1:2:4. repairing section double pole. tightening damaged stays by renosing. tightening the white wires of 33 kv line, each wire and tightening the white wires of lt and 11 kv line, each wire. straightening the skewed poles of 33 kv line/11 kv line/lt line as per respo standard and tying all accessories and erecting them correctly. giving clearance by trimming the trees of 33/11 kv and lt line. spreading the acsr vessel conductor in 33/11 kv line and tying stringing and sagging insulators in all the three phases and jumpering and earthing each wire. replacing damaged cross arm.send feedbackside panelshistorysaved