Get complete information related to latest Acsr Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Acsr Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Acsr Conductor Tenders.
Tender For s/e of pcc poles, acsrconductor 200 kva t/f and 11 mtr. long solar high mast in front of sco 325 to 352 in s/c sector-29 gmm and other works contingent thereto (including 6 year dlp for t/f 5 year dlp for solar high mast and 3 year dlp for other...
Tender For providing elect. in s/c sector-45 hsvp gurugram. s/e of pcc poles, acsrconductor and 200 kva t/f in s/c sector-45 gurugram and all other works contingent thereto (including 6 yeras dlp for t/f and 3 year dlp for other items free of cost)
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
Tender For corrigendum : repair/maint of 33 kv ht line and power transformers, 33 kv structure bay network vcbs and allied works ht network including transformers, panels, acsrconductors ug ht cables and lightning arresters at different locations under ge 969 ews
Tender For corrigendum : special repair /replacement of over head acsrconductor with ug cable lt panels and connected items of stn hq , hq cwe dinjan and hq cce area under ge dinjan
Tender For combined package for the following works, (1)providing intermediate tower between t.nos 06-09 in existing 66kv jalamangala- melehalli sc line on dc towers due to waterlogged at tower no.08 near thimmasandra village, ramanagara town using 66kv narrow based tower with coyote acsrconductor in operations division, kanakapura on total turnkey basis, (2)providing intermediate tower to increase the vertical clearance for existing 66kv kanakapura-chikenahalli-channapatna sc line (proposed 220/66kv mcmv line to kothipura) between t.nos 43-44 near hunasemarradoddi village using 220kv narrow based tower with coyote acsrconductor (modified design of 220kv dc tower of vtp) in operations division, kanakapura (tower will be supplied by kptcl) on partial turnkey basis, (3) providing intermediate tower to increase the vertical clearance of existing 66kv kothipura-ramanagara sc line (proposed 220/66kv mcmv line to kothipura) between t.nos 09-10 at ramanagara town using 66kv kptcl designed narrow based tower with coyote acsrconductor in operations division, kanakapura on total turnkey basis, (4)providing intermediate tower to increase the vertical clearance of existing 66kv maralwadi lilo line between t.nos 08-09 near hucchegowdanadoddi using 66kv kptcl designed narrow based tower with coyote acsrconductor in operations division, kanakapura on total turnkey basis.
Tender For supply of supply laying testing and commissioning ug cable xlpe , material and labour for cable jointing kit end joint for 11 kv , excavating in trenches in hard dense soft soil n exc 1.5 m wide , removing excavated material to a distance not exceeding 50 mtr , returing filling in including spreading levelling watering , material and labour for sand cushioning 8 cm before laying ht lt , material and labour for un- reinforced precast concrete cable , supply and fixing pin type porcelain vitreous white , supply and fixing disc type insulator porcelain vitreous , taking down and supply and fixing acsrconductor , material and labour for earth continuity conductor
Tender For corrigendum : providing additional 1x8mva 66/11kv power transformer & construction of one no. of 66kv line terminal bay for terminating second circuit line at 66/11kv allimaranahalli sub-station in kanakapura taluk ramanagara dist., and making lilo arrangement to the existing 66/11v allimaranahalli sub-station by stringing 2nd circuit line from tap point of 66/11kv allimaranahalli sub-station on 66kv ramanagara-kanakapura sc line to 66/11kv allimaranahalli sub-station on the existing dc towers using coyote acsrconductor for a distance of 0.831kms. including supply of all materials/ equipment (excluding 8mva power transformer & 11kv switchgear) and erection (including civil works) of all materials/ equipments, testing and commissioning on partial turnkey basis
Tender For corrigendum : replacement of existing 1st circuit coyote acsrconductor by htls (equivalent to drake acsr) and stringing of 2nd circuit with htls conductor on exisitng dc towers of 66kv anekal-attibele line from 66/11kv anekal sub-station to 66/11kv attibele sub-station for a distance of 6.545kms.
Tender For repair/replacement of security light,timer panel, solar street light,street light poles,flood light,junction box,acsrconductor and connected allied services at out pockets under ge dinjan no.2