Get complete information related to latest Acsr Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Acsr Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Acsr Conductor Tenders.
Tender For s/e of pcc poles, acsrconductor 200 kva t/f and 11 mtr. long solar high mast in front of sco 325 to 352 in s/c sector-29 gmm and other works contingent thereto (including 6 year dlp for t/f 5 year dlp for solar high mast and 3 year dlp for other...
Tender For providing elect. in s/c sector-45 hsvp gurugram. s/e of pcc poles, acsrconductor and 200 kva t/f in s/c sector-45 gurugram and all other works contingent thereto (including 6 yeras dlp for t/f and 3 year dlp for other items free of cost)
Tender For providing various types of material for various work in fine yaer 2026-27 at vp chinchvad - material, , , , , , mm, mm, mm, mm, square bar 8,10,12,16 mm, , , fly ash , , , , , , x , x , x , x , gi pipe 2 x 2, gi pipe x , gi pipe 1 x 1, gi pipe 1.5 x 1.5 inch, gi pipe 3 x 1.5 inch, gi pipe 3 x3, gi pipe 1 x 3, gi pipe 1 x 2, gi pipe 2 x 4, c angle 25 x 3, c angle 50 x 5, c angle 40 x 5, c angle 65 x 5, f 18 x 4, f 30 x 5, f 20 x 3, gi seet coating, chainlin fencing, 100 x 50, c 75 x 40, ms , 6 mm ms bar, pipe ms 2, pipe ms 1, pipe ms 0.5, rcc cement pipe 150 mm, rcc cement pipe 200 mm, rcc cement pipe 300 mm, rcc cement pipe 450 mm, , , . , . , , , 63 mm pvc pipe, 63 mm l bo, 63 mm t, 63 mm reducer, 63 mm , 63 mm fta, 63 mm mta, 63 mm hdpe pipe, 75 mm pvc pipe, 75 mm l bo, 75 mm t, 75 mm reducer, 75 mm , 75 mm fta, 75 mm mta, 75 mm h.d.p.e pipe, 90 mm pvc pipe, 90 mm l bo, 90 mm t, 90 mm , 90 mm reducer, 90 mm fta, 90 mm mta, 90 mm hdpe pipe, 4 pvc pipe, 4 l bo, 4 t, 4 , , fta, mta, hdpe , 1 hp starter, 3 hp starter, 7.5 hp starter, 12.5 hp starter, 1.25 hdpe, pvc pipe, l , t, , , fta, mta, hdpe , / upvc , / l upvc, / t upvc, / upvc, / upvc, / upvc, / upvc, pvc, pvc, non return volve, air wal, switch wal, mm, , . , , , , , 1.5 hp , kg, kg, kg, , , , , , acrolic colour, , apex color, dam , , , , apex royal color, asian paints ace, asian paints star, , , , , , , , led light 18 vat, led light 20 vat, led flood light 36 vat, led flood light 50 vat, led flood light 100 vat, led flood light 150 vat including lamp with pf7 0.95 class ip 65 and above, frp box size 300 mm x 200 mm x 125 mm 2.7 mm thick complete, supplying erecting and marking dpmcb 6 a to 32 a b series, supplying and errecting street light bracket for erection of double fitting tubulor welded pole with 40 mm dia 1.0 m long b grade gi pipe along with pole cap of 125 mm dia 600, 2 core cable 10 sq mm aluminium conductor with continuos 5.48 sq mm (12 swg), supplying and errecting cost iorn cable indicator plot buried along with route of cable pvc xlpe armaued cable, 9 mtr hight octagonal pole with foundation bolts having bottom of 155 mm a/f top 70 mm a/f provided foundation, gi pipe 40 mm dia or 20 mm dia gi rod, 2 x 4 sqm fr copper pvc insulated wire laid in provided conduct and tracking inside pole bus bars, gi pipe a class 40 mm dia erected for enclosing xlpe armour cableon wall pole, 1.20 m x 0.90 m size information 130 ard 1.25 mm thick
Tender For corrigendum : repair/maint of 33 kv ht line and power transformers, 33 kv structure bay network vcbs and allied works ht network including transformers, panels, acsrconductors ug ht cables and lightning arresters at different locations under ge 969 ews
Tender For repair/replacement of external electric supply distribution network with other connected items at malad, marve and kandivali under ge (n) santacruz, mumbai - supply, install, testing & commissioning pedestal cubical type double door lt bus bar chamber box of suitable size factory made modular construction fabricated out of 3 mm thick crca sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements front & back side opening system including rain shed, busbar chamber should be suitable for accomodating all aluminium bus bar strips (50mm x 10mm x 04 nos) & gi strip for earth fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom part, with fixing arrangement on pcc (1:3:6) type c-2 bed block with studs, bolts, nuts & washers, danger notice board with scull suitable for 415 volts or required size to be fixed on pannel including dismantling of old bus bar panel all as specified and directed by engr-in charge.notes:-(a) aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for phases and neutral - 01 set(b) mccb 4 pole , ics=100%icu- 25 ka, 415 volts, 100 amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 nos.(c) digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable ct of appropriate ratio.-01 no make- imp/automatic electrical(ae)/ l&t / havells/ meco(d) panel indicating lamp neon/led type (red ,yellow & blue) with lamp holders - 03 nos(e) panel instrumental wiring with frls suitable size but not less than 2.5 sqmm copper wire single core - 01 job(f) necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.make of mccb & mcb: larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 400 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:- larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 160 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 16 ka 100 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 250 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb all as specified and directed by engr-in-charge make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supplying, laying,connecting, testing & commissioning lt ug pvc insulated, heavy duty, 1100 v grade electric cable with aluminium conductor of size 16 sqmm x 4 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by engineer-in-charge of following sizes:-note : earthwork excavation, dwc
Tender For corrigendum : special repair /replacement of over head acsrconductor with ug cable lt panels and connected items of stn hq , hq cwe dinjan and hq cce area under ge dinjan
Tender For combined package for the following works, (1)providing intermediate tower between t.nos 06-09 in existing 66kv jalamangala- melehalli sc line on dc towers due to waterlogged at tower no.08 near thimmasandra village, ramanagara town using 66kv narrow based tower with coyote acsrconductor in operations division, kanakapura on total turnkey basis, (2)providing intermediate tower to increase the vertical clearance for existing 66kv kanakapura-chikenahalli-channapatna sc line (proposed 220/66kv mcmv line to kothipura) between t.nos 43-44 near hunasemarradoddi village using 220kv narrow based tower with coyote acsrconductor (modified design of 220kv dc tower of vtp) in operations division, kanakapura (tower will be supplied by kptcl) on partial turnkey basis, (3) providing intermediate tower to increase the vertical clearance of existing 66kv kothipura-ramanagara sc line (proposed 220/66kv mcmv line to kothipura) between t.nos 09-10 at ramanagara town using 66kv kptcl designed narrow based tower with coyote acsrconductor in operations division, kanakapura on total turnkey basis, (4)providing intermediate tower to increase the vertical clearance of existing 66kv maralwadi lilo line between t.nos 08-09 near hucchegowdanadoddi using 66kv kptcl designed narrow based tower with coyote acsrconductor in operations division, kanakapura on total turnkey basis.
Tender For supply of supply laying testing and commissioning ug cable xlpe , material and labour for cable jointing kit end joint for 11 kv , excavating in trenches in hard dense soft soil n exc 1.5 m wide , removing excavated material to a distance not exceeding 50 mtr , returing filling in including spreading levelling watering , material and labour for sand cushioning 8 cm before laying ht lt , material and labour for un- reinforced precast concrete cable , supply and fixing pin type porcelain vitreous white , supply and fixing disc type insulator porcelain vitreous , taking down and supply and fixing acsrconductor , material and labour for earth continuity conductor
Tender For repair/replacement of security light,timer panel, solar street light,street light poles,flood light,junction box,acsrconductor and connected allied services at out pockets under ge dinjan no.2
Tender For corrigendum : providing additional 1x8mva 66/11kv power transformer & construction of one no. of 66kv line terminal bay for terminating second circuit line at 66/11kv allimaranahalli sub-station in kanakapura taluk ramanagara dist., and making lilo arrangement to the existing 66/11v allimaranahalli sub-station by stringing 2nd circuit line from tap point of 66/11kv allimaranahalli sub-station on 66kv ramanagara-kanakapura sc line to 66/11kv allimaranahalli sub-station on the existing dc towers using coyote acsrconductor for a distance of 0.831kms. including supply of all materials/ equipment (excluding 8mva power transformer & 11kv switchgear) and erection (including civil works) of all materials/ equipments, testing and commissioning on partial turnkey basis