Tender For tender for ci valves/ repair of non return valve(nrv) ,pump spare parts & repairs/ bearing ,carriage charges , .labour of pump set opening and fitting. / labour charges ,pump bush steel new / pump bush
Tender For procurement of various spares for fd fans in ahp 210 mw during unit-3 coh at cstps, chandrapur - insertion ring, inner race d35, flexible lovejoy rubber spider, cplng fl lvjy ci with rubber spidr, flexible lovejoy coupling, coupl coupling, valve assy nrv 150 nb, b1 sl fan shaft lock ring metallic, oil remover avas, o ring, blr fd 0 0 si mmer ring ba, blr fdfan 0 0 angular ring, simmer ring for main bearing, blr fd 0 0 ermeto coupling, nut ring dia etc..
Tender For supply of exploded view of fine fuel filter tk t-72 t-90 , exploded view of 70 kg cm , wooden cut model of air compressor , wooden cut model of airpressureregulator , exploded view of hand priming pump of tk t-72 t-90 , exploded view of coarse fuel filter of tk t-72 t-90 , laser presentation remote slide changer , stainless steel telescopic pointer
Tender For tender for supply of mist eliminator : -mist eliminator box including 6 pass pvc mist eliminators and necessary supports and angle frame as per attached specification and drawing for control building -3 air washer , spray nozzle header bank assembly along with ss spray nozzles as per attached specification and drawing for control building -3 air washer. , suction filter frame as per attached specification and drawing for control building -3 air washer , pump drain line with flanges and fittings as per attached specification sheet for control building -3 air washer , pump suction line with flanges and fittings as per attached specification sheet for control building -3 air washer , pump discharge line with flanges and fittings as per attached specification sheet for control building -3 air washer , pump base frame as per attached specification sheet for control building -3 and control building -4 air washer. , suction gate valve of size 100 nb as per attached specification and drawing for control building -3 and control building -4 air washer , discharge globe valve size 80 nb as per attached specification and drawing for control building -3 and control building -4 air washer. , suction strainer 100 nb as per attached specification and drawing for control building -3 and control building -4 air washer , discharge non return valve -nrv- 80 nb as per attached specification and drawing for control building -3 and control building -4 air washer. , removal of the existing mist eliminator bank , spray nozzle headers , suction filter bank , pump suction and discharge lines , its valves and strainers , drain line and pump base frame and disposal of same to waste disposal facility for control building -3 airwasher. , fabrication , installation , erection of the mist eliminator bank , spray nozzle headers , suction filter bank , pump suction and discharge lines , including installation of the valves and strainers , installation of the drain line and pump base frame for control building -3 air washer , mist eliminator box including 6 pass pvc mist eliminators and necessary supports and angle frame as per attached specification and drawing for control building -4 airwasher. , spray nozzle header bank assembly along with ss spray nozzles as per attached specification and drawing for control building -4 air washer. , suction filter frame as per attached specification and drawing for control building -4 air washer , pump drain line with flanges and fittings as per attached specification sheet for control building -4 air washer. , pump suction line with flanges and fittings as per attached specification sheet for control building -4 air washer , pump discharge line with flanges and fittings as per attached specification sheet for control building -4 air washer. , removal of the existing mist eliminator bank , spray nozzle headers , suction filter bank , pump suction and discharge lines , its valves and strainers , drain line and pump base frame and disposal of same to waste disposal facility for control building -4 air washer. , fabrication , installation , erection of the mist eliminator bank , spray nozzle headers , suction filter bank , pump suction and discharge lines , including installation of the valves and strainers , installation of the drain line and pump base frame for control building -4 air washer
Tender For tender for supply of amc for ro water purifiers : - maint. of 50 lph water purifiers eureka , maint. of 25 lph water purifiers eureka , membrane reviva , carbon filter ac block 20inch , solenoid valve , o ring 86 x 4mm , pre filter cartridge 20inch , smps 48 v , pvc pipe , pre filter nozzle 3/8 , float valve with microswitch reviva nxt , auto pcb 48 v flush , diaphram pump 1800 ml , flow reducer tube frt 800 ml , t connector , forbes pro ro kit , maint. of 50 lph water purifiers eureka , maint. of 20 lph water purifiers aquafresh , membrane reviva , carbon filter ac block 20inch , solenoid valve ag , o ring 86 x 4mm , pre filter cartridge 20inch , smps 48 v , pvc pipe , pf nozzle 3/8 , float valve with microswitch reviva nxt , auto flush pcb 48 v flash , diaphram pump 1800 ml reviva , flow reducer tube frt 800 ml , t connector , dual cartridge v compact , uv lamp 16 watts short nl hiflo p , photoresistor harness assy , pcb assly. new hiflo , pf candle i nova , diaphragm pump 1800 ml aquaguard , 3/4 nut nozzle assy with washer , smps 48 v , harness for display pcb ag 200 , display pcb ag 200 , maint. of 15 lph water purifiers kent , powp inline sediment filter 8 inch , powp inline carbon filter 8 inch , kent uf membrame , kent membrane hi flow , kent pump 100psi , kent smps 2.5 a 24vdc , kent electric float valve g , pipe pl 4 , kent solenoid valve 24vdc , kent frt 550 , powp pre filter sediment 10 inch , needle control valve assembly , non return valve nrv pv3l040 , elbow pl0404 for 1/4 pipe