Get complete information related to latest Air Rotor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Air Rotor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Air Rotor Tenders.
Tender For impregnation / repair / rewinding of 25 hp motor alongwith allied works at malhar intake stage-0, repair to 50 ampere lt control panel alongwith allied works at malhar intake stage-0, repair to 100 kva voltage stabilizer alongwith allied works at ma
Tender For tender for repair and overhauling of genr set 7 5 kva regd no 2685k , repair and overhauling of genr set 25 kva regd no 438 , repair and overhauling of genr set 5 kva regd no 1901110 , repair and overhauling of genr set 5 6 kva regd no 4038 , rewinding of servo motor operated line voltage corrector regd no 1708
Tender For corrigendum : annual operation & day to day maintenance of internal & external e&m installations at goa international airport for the year 2026-2028. - servicing, testing and checking of breakers , "servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 800-1600 a " , "servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 2000 a - 2500a " , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. l&t make acb of rating 3200a - 4000a , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. schneider make acb of following rating , servicing, checking and testing of lt air-circuit breakers including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. ge make acb of following rating , one time servicing, checking and testing of 33kv vaccum circuit breakers (vcb) including testing of wiring of standards and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of oem / agency approved by engineer-in-charge) followed with submission of test report to aai. make jyoti , servicing, checking and calibration of the following relays as per recommended standards and submission of calibration report complete as required through authorised agency of oem / agency approved by engineer-in-charge. , servicing of 3x 4kw grundfos make hydropneumatic pumps along with control panel which includes cleaning, safety check, motor, gear box, drive check, vfd parameters check etc. as per oem recommendation through oem or authorised service partner of oem. , servicing of 0.55 kw - 5kw grundfos make pumps which includes cleaning, safety check, motor, gear box, drive check etc. as per oem recommendation through oem or authorised service partner of oem. , dehydration & filteration of transformer oil of 1000 kva transformer of aai residential colony to improve the breakdown voltage of oil up to 50 kv by oil filtration machine and carrying out bdv test of oil, top up of transformer oil etc. by keeping the dehydration equipment out side the 33kv yard including transportation of filtration machine up to site etc. complete as required (excluding the cost of transformer oil). , "the execution of items mentioned in cpwd, delhi schedule of rates (e&m) 2025 for electrical repair and maintenance of electrical e&m installations as and when required as per direction of engineer-in-charge at goa airport for period of two years. agency will quote against basic rate of rs. 5,00,000.00 (say x) (including gst) in ""rate column"" for examples : (i) if bidder is quoting rs. 4,00,000.00 (including gst) (y1) then it will be
Tender For corrigendum : supply of ecg patient cable 10 lead , ecg cable 7 pin round , spo2probe 6 pin single notch , spo2 6 pin double notch , bp cuff digital , endo motor , high speed airrotor hand piece with led
Tender For water treatment plant cleaning,purchasing of equipments for wtp, laying of di pipes and sluice valves, construction of sv chamber and phed esr repairing for jamtara nagar panchayat. - labour for site clearance -do--e/i, desilting the supply well, intake well /head works, sump of water supply /sewerage works etc. in wet or dry condition including lifts upto 9 m and lead upto 150m as required beyond the work site,stacking, spreading, including necessary guarding, etc. complete, as directed by e/i, supplying and laying of rapid sand gravity filter sand, supplying and laying of rapid sand gravity filter gravel, supplying of bamboo for scaffolding works, supplying of narial ropes for binding works submersible pump set, requirement of plumber class-ii for opening & closing of valve & other related works, requirement of electrician grade-ii for making required connections & other related works, hiring of different tools,chain pulley & tackles for cleaning & other works, disposal of excavated earth & filter bed sand, sand (lead 02k+10p=12 km), gravel (22 k.m. lead), tyre coupling (unique 3409-gn tyre coupling for 100hp & 50hp), bosch lithium based grease, graphit gland pack rope 12mm, graphit gland pack rope 16mm, 2.2kw (3hp) foot mounted motor tefc 1500 rpm 3-phase motor for clariflocculator, multi-blade paddles mounted on central shaft driven by foot-mounted geared motor, onload changeover switch 800a,415v, 4 pole, digital voltmeter (0-500v)-3 phase indicator, digital ammeter (0-500a)-3 phase indicator, led indicator lamp or phase light (r/y/b/g), pvc/xlpe insulated pvc sheated heavy duty,armoured lt cable with aluminium conductor voltage upto and including 1100 v, 240sqmm, 3.5 core, 2.5 sqmm isi marked frls pvc insulated, single core copper conductor cable, 1.5 sqmm isi marked frls pvc insulated, single core copper conductor cable, laying of one number pvc insulated and sheated/xlpe power cable of 1.1kv grade of size not exceeding 35sqmm direct in ground including excavation, sand cushioning and refilling the trench, tapered bearing 7316 mcb (large), deep groove ball bearing 6311 mcb (small), chain pulley block hoist 5 tonne, 360 rotation, 3mtr lifting height, pipe wrench, 18 inch taparia adjustable heavy duty pipe wrench, pipe wrench, 14 inch taparia adjustable heavy duty pipe wrench, 1/2" sqaure drive flank drive taparia goti 22mm socket set, 1/2" sqaure drive flank drive taparia goti 20mm socket set, rachet wrench, 18 inch single sided rachet wrench, 1/2 inch drill bit for threading di/ci pipe, tata agrico hammer -dfs- 2.5kg, 6 inch tyton epdm/sbr rubber gasket for 150mm di pipe conforming to is:5382 isi mark, 4 inch tyton epdm/sbr rubber gasket for 100mm di pipe conforming to is:5382 isi mark, 6 inch di end cap flanged type for 150mm di pipe, 4 inch di end cap flanged type for 100mm di pipe, epdm rubber gasket for non-return valve, earthwork in excavation in foundation (as per i.s. 3114/1965 for laying of different types & sizes of pipes) so as to give one meter average cover over the the socket of pipe with disposal of excavated earth within initial lead lift as per specification & direction of e/i (k-7 150mm), earthwork in excavation in foundation (as per i.s. 3114/1965 for laying of different types & sizes of pipes) so as to give one meter average cover over the the socket of pipe with disposal of excavated earth within initial lead lift as per specification & direction of e/i (k-7 100mm), earthwork in excavation in foundation (as per i.s. 3114/1965 for laying of different types & sizes of pipes) so as to give one meter average cover over the the socket of pipe with disposal of excavated earth within initial lead lift as per specification & direction of e/i (k-7 100mm repair), earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches wit