Get complete information related to latest Aluminum Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Aluminum Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Aluminum Conductor Tenders.
Tender For providing various types of material for various work in fine yaer 2026-27 at vp chinchvad - material, , , , , , mm, mm, mm, mm, square bar 8,10,12,16 mm, , , fly ash , , , , , , x , x , x , x , gi pipe 2 x 2, gi pipe x , gi pipe 1 x 1, gi pipe 1.5 x 1.5 inch, gi pipe 3 x 1.5 inch, gi pipe 3 x3, gi pipe 1 x 3, gi pipe 1 x 2, gi pipe 2 x 4, c angle 25 x 3, c angle 50 x 5, c angle 40 x 5, c angle 65 x 5, f 18 x 4, f 30 x 5, f 20 x 3, gi seet coating, chainlin fencing, 100 x 50, c 75 x 40, ms , 6 mm ms bar, pipe ms 2, pipe ms 1, pipe ms 0.5, rcc cement pipe 150 mm, rcc cement pipe 200 mm, rcc cement pipe 300 mm, rcc cement pipe 450 mm, , , . , . , , , 63 mm pvc pipe, 63 mm l bo, 63 mm t, 63 mm reducer, 63 mm , 63 mm fta, 63 mm mta, 63 mm hdpe pipe, 75 mm pvc pipe, 75 mm l bo, 75 mm t, 75 mm reducer, 75 mm , 75 mm fta, 75 mm mta, 75 mm h.d.p.e pipe, 90 mm pvc pipe, 90 mm l bo, 90 mm t, 90 mm , 90 mm reducer, 90 mm fta, 90 mm mta, 90 mm hdpe pipe, 4 pvc pipe, 4 l bo, 4 t, 4 , , fta, mta, hdpe , 1 hp starter, 3 hp starter, 7.5 hp starter, 12.5 hp starter, 1.25 hdpe, pvc pipe, l , t, , , fta, mta, hdpe , / upvc , / l upvc, / t upvc, / upvc, / upvc, / upvc, / upvc, pvc, pvc, non return volve, air wal, switch wal, mm, , . , , , , , 1.5 hp , kg, kg, kg, , , , , , acrolic colour, , apex color, dam , , , , apex royal color, asian paints ace, asian paints star, , , , , , , , led light 18 vat, led light 20 vat, led flood light 36 vat, led flood light 50 vat, led flood light 100 vat, led flood light 150 vat including lamp with pf7 0.95 class ip 65 and above, frp box size 300 mm x 200 mm x 125 mm 2.7 mm thick complete, supplying erecting and marking dpmcb 6 a to 32 a b series, supplying and errecting street light bracket for erection of double fitting tubulor welded pole with 40 mm dia 1.0 m long b grade gi pipe along with pole cap of 125 mm dia 600, 2 core cable 10 sq mm aluminium conductor with continuos 5.48 sq mm (12 swg), supplying and errecting cost iorn cable indicator plot buried along with route of cable pvc xlpe armaued cable, 9 mtr hight octagonal pole with foundation bolts having bottom of 155 mm a/f top 70 mm a/f provided foundation, gi pipe 40 mm dia or 20 mm dia gi rod, 2 x 4 sqm fr copper pvc insulated wire laid in provided conduct and tracking inside pole bus bars, gi pipe a class 40 mm dia erected for enclosing xlpe armour cableon wall pole, 1.20 m x 0.90 m size information 130 ard 1.25 mm thick
Tender For repair/replacement of external electric supply distribution network with other connected items at malad, marve and kandivali under ge (n) santacruz, mumbai - supply, install, testing & commissioning pedestal cubical type double door lt bus bar chamber box of suitable size factory made modular construction fabricated out of 3 mm thick crca sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements front & back side opening system including rain shed, busbar chamber should be suitable for accomodating all aluminium bus bar strips (50mm x 10mm x 04 nos) & gi strip for earth fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom part, with fixing arrangement on pcc (1:3:6) type c-2 bed block with studs, bolts, nuts & washers, danger notice board with scull suitable for 415 volts or required size to be fixed on pannel including dismantling of old bus bar panel all as specified and directed by engr-in charge.notes:-(a) aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for phases and neutral - 01 set(b) mccb 4 pole , ics=100%icu- 25 ka, 415 volts, 100 amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 nos.(c) digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable ct of appropriate ratio.-01 no make- imp/automatic electrical(ae)/ l&t / havells/ meco(d) panel indicating lamp neon/led type (red ,yellow & blue) with lamp holders - 03 nos(e) panel instrumental wiring with frls suitable size but not less than 2.5 sqmm copper wire single core - 01 job(f) necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.make of mccb & mcb: larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 400 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:- larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 160 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 16 ka 100 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 250 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb all as specified and directed by engr-in-charge make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supplying, laying,connecting, testing & commissioning lt ug pvc insulated, heavy duty, 1100 v grade electric cable with aluminium conductor of size 16 sqmm x 4 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by engineer-in-charge of following sizes:-note : earthwork excavation, dwc
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminumconductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
Tender For regarding supply of lt 1.1 kv 3.5 core aluminumconductor 120mm2 xlpe insulated armoured cable for connection from panel to motors along with providing suitable size of thimbles at flood site rd 36000 loharu canal.
Tender For corrigendum : repair to security lights panels dg sets fire alarm ups with covered items at af stn bikaner under ge (af) nal - excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m depth, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed by engineer-in-charge., removal of excavated material soils to a distance n exc 50 m and depositing where directed at a level not exceeding 1.5m above the startly point complete all as specified and directed., returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm as in any type of soil complete all as specified and directed., material and labour for sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. note : punned thickness shall be measured for payment., material and labour for un-reinforced pre-cast concrete cable covers, class lv type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed., taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminumconductor 2 core, 6 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminumconductor 2 core, 10 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminumconductor 4 core, 16 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminumconductor 3.5 core, 25 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminumconductor 3.5 core, 35 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminumconductor 3.5 core, 50 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 6 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge , supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 10 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 4 core 16 sqmmlaid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core 25 sqmm laid in trenches
Tender For corrigendum : erection of 01 nos 33kv rewan bay with supply of material, integration and remote gateway work at 220kv ss bangra under etd jhansi - erection of following different type main and auxiliary structur, columns, beams, peaks, masts ets. suitable for placing of kv equipments., main structure & auxiliary structure., erection of following equipments as per instruction manual of various equipments and technical specification including shifting of material / equipments from sture to erection site including all other associated work to complete the job satisfactorily., 36kv v.c.b., 36kv bi, 36kv li, 36kv ct, ct junction box, cutting. strenghtening. bending. laying 700mm. below in side ground and above ground og following size of ms flat for earthing of main and auxiliary structure. equipment structure t/f body and its material etc. including welding with main earth mat and with object to be earthing / excavation of trenches its back filling., 75x10mm ms flat, 50x6mm ms flat, 25x10mm ms flat, provinig, fixing & installation of glow sign board (as per sample) of size 8ft x 6ft for updated substation single line diagram duly checked & verified by concerned ae, to be fixed in control room building of substation with all other associated work to complete the job satisfactorily as per drawing and technical specn. of upptcl, the glow sign board illumminated using led tube light in sufficient quantity. the board shall be made of acrylic sheet of suitable thickness and color and shall be provided with back support frame & fixing arrangement with wall., interconnection of equipments and bus bar including cutting. bending of conductor and jumping, clamping along with all other associated work to complete the job satisfactorily as per drawing and technical specn., equipment jumper with 1xmoose, 10mtr, 33kv, bus bar jumper with 1xmoose, 10mtr, 33 kv, 6m, laying of following sizes of control cable in the cable trench from control relay panel to various equipments / marshalling boxes and jb etc. in switchyard as per cable schedule., 2c x 2.5 sq mm. unarmoured., 4c x 2.5 sq mm. unarmoured., 6c x 2.5 sq mm. unarmoured., termination of 2cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., termination of 4cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., termination of 6cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., preparation of cable schedule and case interconnection diagram in between relevant panel,cb,ct,pt,etc.., providing and fixing of led street light luminaries, single piece aluminum body suitable for 120 watt having lumen output not less than 10,000 nom on 9 mtr. long stp/substation main structure column with g.1. pipe bracket complete in all respect cat. a philimps bajaj/ crompton/havells or equivalent make including cost of g.1. pipe brackets and all related accessories., supply, supply of single tension fitting suitable for acsr moose as per sample, supply of single suspension fitting suitable for acsr moose as per sample, supply of 33kv ct clamps suitable for acsr moose as per sample, supply of 36kv isolator jaw as per sample, supply of copper bond 16x500mm, supply of 33 kv isolator clamps suitable for acsr moose as per sample, intregration & remote gateway work, supply of required material with installation and intregration of new 33 kv line control & relay panel with iec -61850 compliant ied with existing automation system and addition of bay into remote gateway & data validation work.
Tender For corrigendum : erection of 01 nos 33 kv birdha bay with supply of material, integration and remote gateway work at 220kv ss birdha under etd jhansi - erection of following different type main and auxiliary structur, columns, beams, peaks, masts ets. suitable for placing of kv equipments., main structure & auxiliary structure., erection of following equipments as per instruction manual of various equipments and technical specification including shifting of material / equipments from sture to erection site including all other associated work to complete the job satisfactorily., 36kv v.c.b., 36kv bi, 36kv li, 36kv ct, ct junction box, cutting. strenghtening. bending. laying 700mm. below in side ground and above ground og following size of ms flat for earthing of main and auxiliary structure. equipment structure t/f body and its material etc. including welding with main earth mat and with object to be earthing / excavation of trenches its back filling., 75x10mm ms flat, 50x6mm ms flat, 25x10mm ms flat, provinig, fixing & installation of glow sign board (as per sample) of size 8ft x 6ft for updated substation single line diagram duly checked & verified by concerned ae, to be fixed in control room building of substation with all other associated work to complete the job satisfactorily as per drawing and technical specn. of upptcl, the glow sign board illumminated using led tube light in sufficient quantity. the board shall be made of acrylic sheet of suitable thickness and color and shall be provided with back support frame & fixing arrangement with wall., interconnection of equipments and bus bar including cutting. bending of conductor and jumping, clamping along with all other associated work to complete the job satisfactorily as per drawing and technical specn., equipment jumper with 1xmoose, 10mtr, 33kv, bus bar jumper with 1xmoose, 10mtr, 33 kv, 6m, laying of following sizes of control cable in the cable trench from control relay panel to various equipments / marshalling boxes and jb etc. in switchyard as per cable schedule., 2c x 2.5 sq mm. unarmoured., 4c x 2.5 sq mm. unarmoured., 6c x 2.5 sq mm. unarmoured., termination of 2cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., termination of 4cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., termination of 6cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., preparation of cable schedule and case interconnection diagram in between relevant panel,cb,ct,pt,etc.., providing and fixing of led street light luminaries, single piece aluminum body suitable for 120 watt having lumen output not less than 10,000 nom on 9 mtr. long stp/substation main structure column with g.1. pipe bracket complete in all respect cat. a philimps bajaj/ crompton/havells or equivalent make including cost of g.1. pipe brackets and all related accessories., supply, supply of single tension fitting suitable for acsr moose as per sample, supply of single suspension fitting suitable for acsr moose as per sample, supply of 33kv ct clamps suitable for acsr moose as per sample, supply of 36kv isolator jaw as per sample, supply of copper bond 16x500mm, supply of 33 kv isolator clamps suitable for acsr moose as per sample, intregration & remote gateway work, supply of required material with installation and intregration of new 33 kv line control & relay panel with iec -61850 compliant ied with existing automation system and addition of bay into remote gateway & data validation work.
Tender For supply and erection of wall mounting type, solenoid driven, motorized, electromagnetic diaphragm dozing metering pump working on three-phase 220/240 v 50 hz electric supply with standard electronic controls, suitable for minimum dozing capacity 0 to 27 lph at 10 bar back pressure complete with necessary accessories, complete in all respects along with supply and erection of 1 no. voltage stabilizer with dozing pump along with 1 no. 300 litres capacity isi marked hdpe storage tank of approved make as per directions of engineer-in-charge ,supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with pvc for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with is:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of engineer- in-charge. submersible copper cable 3 core 10 sqmm
Tender For supply of 11 kv (e) grade, 3 core, 185sqmm, stranded compact circular aluminumconductor, conductor screened with extruded semi conducting compound, xlpe insulated, insulation screened with extruded semiconducting compound followed by copper tape screen. cores shall be laid up together with pvc fillers, extruded pvc inner sheathe, galvanized steel strip armored and overall pvc sheathed cable, conforming to is: 7098 part ii/1985 or latest amendment with isi mark. [ warranty period: 12 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of modernization of distribution infra 2x400 kva substation companybagh b b -dismantling and refurbishing of electrical distribution system , itc of existing load bank with static meter , itc of existing load bank , trimming and pruning of four trees , transportation of one dismantled lt panel darbhanga to mzp , removing of old faulty outlived mv panel , provision of structural iron channels mounting framework for the lt panel , re-furbishment of existing mv panel , brickwork for minor structural alterations near the lt panel support base , straight through joint 185 , straight through joint 50 , removing and relaying of existing cement interlocking bricks , laying of 1.1 kv grade of 35 sqmm to 185 sqmm direct in ground , dressing of cables , finishing of the lt bus bar box , 20w surface-mounted led tube light , a. horizontal type tpn db 8 way with double door , b. horizontal type tpn db 8 way single door , a. vertical type, 415 v, tpn db 8 way double door , dressing of dbs , a. single pole mcb 6 to 32 a , b. four pole isolator 63 a , c. four pole isolator 40 a , d. double pole isolator 40 a , e. tp mcb 63 a , f. 125 a tp mccb 16 ka , 3 pole mccb of 250a, 25 ka , itc of existing lt bus bar box , sitc wall mounted heavy-duty air circulators fans of 600mm metal blades , supplying and fixing of 5mm thick m.s.chequered plates , fixing of ms stand of pac outdoor unit , providing double coat spray painting , sign writting numbering on all panel proper marking of its connectivity , a. wiring for light point group-a , a. copper conductor, single core cable 2 x 1.5 sq. mm , a. medium class pvc conduit 20 mm , shifting re- installation of submersible pump staters , making opening of wall to suit the size of 380 mm sweep exhaust fan , supplying fixing of exhaust fan of 380 mm sweep heavy duty , a. blanking plate , b. 5 pin 15 a socket , c. 15 16 a piano type switch , d. 5 6 a piano type switch , e. 3 pin 5 6 a socket outlet , f. 3 pin 15 a top , g. wall fan , h. down rod for ceiling fan installation 3 ft length hook , a. 100 watt flood light , b. 24 w led rimless surface panel light , sitc of 100 a 3 phase neutral copper bus bar in sheet steel enclosure , dressing of existing distribution system of type ii staff qtr , itc of 100 a 3 phase neutral bus bar with 100 a mccb in sheet steel enclosure , supplying fixing of double pole spn mcb 32 a in the sheet steel enclosure , s l 2 1.5 sqmm copper conductor , removing the faulty lt cable of size 3.5 core 240 sq.mm , ms clamp on four pole structure for fixing the ht cable , extracting of spare main ht cable 11 kv 95 sq mm size from the soil , extracting of faulty spare ht cable 95 sq mm from the duct manual labour , fastners nut bolt, al lugs, socket, cu lugs socket, washers, screw, pvc clips , acrylic sheet of 2 mm thickness , hrc fuse of 200 a //bid details 2 / 49