Web Analytics Made Easy - StatCounter

Amf Control Panel Tenders

Get complete information related to latest Amf Control Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Amf Control Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Amf Control Panel Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45743718 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For 250 kva diesel generator set with amf control panel, power generator installation configuration as defined in cpwd general specifications for electrical works-part-vii (dg set) -fixed (power generators are permanently installed), nominal rated capacity (kva)-250, rated engine power(kwa)- 110% of the required powered at stp (standard temperature pressure) i.e equal ? to (nominal rated capacity (kva) of power generator any auxiliary power consumption by the power generator) x power factor (0.8)/alternator efficiency , type of governor-electronic, rated rpm of engine(rpm)-1500, fuel-high speed diesel (hsd),control panel-amf control panel , installation- with installation-inclusive in the scope of supply, warranty on complete power generator/dg set-24 months , no . of phase- 3, number of cylinders-6,starting voltage-24, type of alternator-brushless, fuel tank capacity- 600 liter, battery capacity(ah)-100,no. of battery2, testing report available for (test/approval)-type approval certificate for the specified rating of the power generator from any of the designated agency authorized by cpcb,cop certificate for engine type test report and endurance test report for engine as per is :10001 latest/ls:10002 latest,type test report for alternator as per is : 13364 (part-1) latest/is: 13364 (part-2) latest to prove conformity to the specification , make-cummins power, greaves, kirloskar or similar. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45546255 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For corrigendum : 250 kva diesel generator set with amf control panel, power generator installation configuration as defined in cpwd general specifications for electrical works-part-vii (dg set) -fixed (power generators are permanently installed), nominal rated capacity (kva)-250, rated engine power(kwa)- 110% of the required powered at stp (standard temperature pressure) i.e equal ? to (nominal rated capacity (kva) of power generator any auxiliary power consumption by the power generator) x power factor (0.8)/alternator efficiency , type of governor-electronic, rated rpm of engine(rpm)-1500, fuel-high speed diesel (hsd),control panel-amf control panel , installation- with installation-inclusive in the scope of supply, warranty on complete power generator/dg set-24 months , no . of phase- 3, number of cylinders-6,starting voltage-24, type of alternator-brushless, fuel tank capacity- 600 liter, battery capacity(ah)-100,no. of battery2, testing report available for (test/approval)-type approval certificate for the specified rating of the power generator from any of the designated agency authorized by cpcb,cop certificate for engine type test report and endurance test report for engine as per is :10001 latest/ls:10002 latest,type test report for alternator as per is : 13364 (part-1) latest/is: 13364 (part-2) latest to prove conformity to the specification , make-cummins power, greaves, kirloskar or similar. [ warranty period: 30 months after the date of delivery ] ]

State Government

CTN :45699085 Due date: 25 Jun, 202625 Jun, 2026 86.44 Lacs
Tender For supply, installation, testing and commissioning of 400 kva, 3 phase, 415v water cooled silent type diesel generator set including all accessories with amf control panel at pandu pokhar - rajgir and papharni talab - mandar, banka.

Corporations And Associations And Others

CTN :45696293 Due date: 02 Jul, 202602 Jul, 2026 17.54 Lacs
Tender For supply of electrical materials for day to day maintenance of electrical assets at various permanent mixed/storm pumping stations under eee-i shahdara (north) zone - supply of 9 watt led retrofit lamp suitable for b22 holder, supply of cceiling fan with brush less direct current (bldc) motor, etc. complete as req , 1200mm, bee 5 star rating, service value 6.0 cm/min/watt, air delivery 210 cm/min (minimum), supply of led batten light (system lumen efficacy 120 135 lm/watt) of following body materials. powder coated die cast /extruded aluminium body (thickness > 1.20 mm) 18-22 watt, supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan fresh air type complete with shutter blades etc. as required., supply of 15 inch (300mm) sweep 1400 rpm exhaust fan heavy duty complete with shutters, blades etc as required., suppy of 1.5 sq. mm isi marked, frls/hffr pvc insulated, single core copper conductor cable, supply of 4.0 sq. mm isi marked, frls/hffr pvc insulated, single core copper conductor cable, supply of 2.5 sq. mm isi marked, frls/hffr pvc insulated, single core copper conductor cable., supply of 10 sq. mm isi marked, frls/hffr pvc insulated, single core copper conductor cable., supply of 6.0 sq. mm isi marked, frls/hffr pvc insulated, single core copper conductor cable., supply of 16 sq. mm isi marked, frls/hffr pvc insulated, single core copper conductor cable, supply of 125 a, tpn, switch disconnector fuse unit (panel mounted type) with isi marked hrc fuses, supply of 200a tpn switch fuse unit with isi marked hrc fuses, supply of 4 pole mccb, 125a, 36ka ics=100% icu and operational voltage 690v, supply of 4 pole mccb,250a, 50ka ics=100% icu and operational voltage 690v, supply of 4 pole mccb,400a, 50ka ics=100% icu and operational voltage 690v, supply of 4 pole mccb,630a, 50ka ics=100% icu and operational voltage 690v, supply of 3 pole mccb, 200a, 16ka ics=100% icu and operational voltage 690v, supply of 3 pole mccb, 125a, 16ka ics=100% icu and operational voltage 690v, supply of 3 pole mccb, 250a, 35ka ics=100% icu and operational voltage 690v, supply of 3 pole mccb, 400a, 35ka ics=100% icu and operational voltage 690v, supply of brass batten/angle holder, supply of 6 pin 15/16 & 5/6 a socket outlet, piano type isi marked, supply of s.p. 15/16 a, one way switch, piano type isi marked, supply of 3 pin 5/6 a socket outlet, piano type isi marked, supply of s.p. 5/6 a, one way switch, piano type isi marked, supply of stepped type modular fan regulator (2 module), supply of 3 mm thich phenolic laminated sheet, supply of 63 amp, 4 pole isolator., supply of 63 amp, 2 pole isolator., supply of 40 amp, 2 pole isolator., supply of 6 to 32 a, ratings sp mcb, c curve, 10 ka braking capacity, supply of 6 to 32 a, ratings dp mcb, c curve, 10 ka braking capacity, supply of 6 pin 15/16 a modular socket outlet, isi marked, supply of 3 pin 5/6 a, modular socket outlet, isi marked, supply of s.p. 15/16 a, one way modular switch, isi marked, supply of s.p. 5/6 a, one way modular switch, isi marked, supply of led flood light, powder coated pressure die cast aluminium (system lumen efficacy >135 lm/watt) of following body materials. 150 watt

Central Government/Public Sector

CTN :45697889 Due date: 16 Jul, 202616 Jul, 2026 NA
Tender For tender for supply of supply, installation , testing and commissioning of 58.5 kva diesel generating sets, three phase, 415v with amf control panel type of engine cooling :liquid cooled, rated rpm of engine(rpm): 1500, type of alternator : brushless, class of insulation: h,battery capacity(ah) : 120 , no of batteries: 1 or more,cpcb-iv+ emission norms,insulation classclass-h,starting system-electric start,standardscpwd specifications, wr approve make list attached. supply and commissioning of battery operated platform truck, load capacity-4000 kg. make/model :-josts / godrej / voltas / jaldoot or equivalent. hand operated pneumatic barrel pump, dual directional pump of inlet 01 inch, deliver 05 liters in 20 turn, wetted components steel, cast iron, nbr, complete with 01 nos 2meter long flexible delivery pipe. suitable to barrel capacity 210/220 liter brand: prachand, lubi, toss, kingom, lavaka, skope, (detailed description/specification as per product # 1 of gem contract no. gemc-511687710211457 dt.19/04/2026 , two wheeler tyre with tube (bullet motorcycle) size 110/90-18 m/c 61p and 90/90-19 m/c 52p brands like mrf, ceat or similar. tyre with tube for mp-43-g-1645 vehicle model no. 215/75 r15 make/brand : ceat, jk, mrf or as similar. tyre with tube for bullet motorcycle size-(90/90-19 m/c 52p), make-mrf. steel radial tyre with tube for departmental vehicle make- mrf/apollo/ceat only with warranty as per manufacturer and enclosed annexure-l - 1. ashok leyland dost tyre size 185 r14 (185mm section width for a 14-inch rim). steel radial, ply rating-10pr, for 02 vehicles with stepney. 2. mahindra maxx, tyre size7.00 r 15 (7.00 inch section width, 15-inch rim diameter). steel radial, ply rating-12pr, for 01 vehicle with stepney. 3. eicher truck, tyre size 8.25-20 (20-inch rim diameter) steel radial, ply rating-16pr, for 01 vehicle with stepney.

CTN :45679372 Due date: 02 Jul, 202602 Jul, 2026 20.16 Lacs
Tender For supply and replacement of defective parts of kirloskar make transformers of 1000/750/500 kva capacity at ugc & cag building, new delhi. - supply and fixing of over current earth fourth relay 24 dc l&t make etc complete as reqd. , supply and fixing of 11 kv indoor single phase resin cast current transformer 300/5amp etc complete as reqd., , supply and fixing of transformer 500 kva 11/0.433 kv wt1 scanner & rtd sencer lead., , supply & installation of suitable rating of 500 kva 11/0.433 kv lv bussing porcelain or epoxy-cast resin comply with is-1180 complete as required, , supply and fixing of suitable rating of 500 kva 11/0.433 kv lv flexible porcelain or epoxy-cast resin comply with is-1180 complete as required., , dismantling /loading and unloading of 500kva, 11kv/433volt, 3phase, 50hz, cast resin dry type kirloskar make indoor transformer hv/lv coil/core etc and repair of crack in hv/lv winding/core and putting cast resin/resin hardener, reassembling all the dismantle parts accessories confirming to is 11171 and iec 60076 etc including all tests i.e voltage ratio, magnetic balancing, vector group, ir magnetizing current, winding resistance etc complete as reqd., , supply & installation of 630a vcb vacuum interrupter etc complete as reqd., , sh-2 (old cag bldg), , supply and replacement of 750- 1000 kva transformer oil gas kit etc complete as reqd., , checking in 750-1000 kva transformer all type of protection etc complete as reqd., , supply and replacement of lv bushing oil seal in 750-1000 transformer etc complete as reqd. no.ryb) (4, , supply and replacement of hv bushing oil seal in 750-1000 transformer etc complete as reqd. (3 no. r,y, b), , supply and replacement of off load tape changer in 750-1000 kva transformer etc complete as reqd., , replacement of transformer oil in oltc top-up of main tank etc complete as reqd., transformer oil filtration and dehydration of 750 kva & 1000 kva transformer using high-vacuum oil filtration plant, including removal of moisture, dissolved gases, sludge and impurities from transformer oil, circulation of oil through filtration machine, achieving required bdv value, testing before and after filtration, manpower, tools & tackles, consumables, complete as required at site., , complete servicing, overhauling, cleaning, contact checking, lubrication, insulation resistance testing, contact resistance testing, functional testing and commissioning of oil circuit breaker (ocb), complete as required at site., , supply & installation of male contact, , supply & installation of female contact, , supply & installation of over current earth fault relay, , supply & installation of 24 volt dc power pack unit etc complete as reqd., , supply and fixing of transformer wti relay etc complete as reqd.., , supply and replacement of transformer oti relay etc complete as reqd.., , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, ics=100% icu and operational voltage 690v etc. as required., , (make: schneider electric-nsx /siemens / lk/ abb/hager)

CTN :45048307 Due date: 31 Jul, 202631 Jul, 2026 NA
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp

Central Government/Public Sector

CTN :45329483 Due date: 29 Jun, 202629 Jun, 2026 12.61 Lacs
Tender For corrigendum : provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate nu

corporations/Associations/Others

CTN :45628421 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For tender for supply of spare parts - power contactor 16a at 415v ac coil 24v dc model3tf32 00 0bb4 power contactor biasing damper 24vdc siemens , siemens 3rh1921 1ba01 auxiliary contact block make siemens model 3rh19211ba01 type front top mounted auxiliary contact block contacts 1 no normally open electrical ratings pilot dutyac a600 600 v ac 10 a continuous dc q600 300 v , siemens 3rh19211ca01 auxiliary contact block make siemens model 3rh19211ca01type front top mounted auxiliary contact block contacts 1 nc electrical ratings pilot duty ac , siemens 3tf30 100a power contactor aa11 make siemens model 3tf30 100a type power contactor poles 3 main poles rated operational current ac3 9 a at 415 v ac auxiliary contacts 1 no integrated coil voltage 110 v ac 50 60 hz rated insulation voltage ui 690 v utilization category ac3 ac4 mounting din rail or screw mounting standards iec 6094741 is iec60947 4 kw at 400 v ac power contactor silo , 3ua52 002a thermal overload relay make siemens model 3ua52 002a type thermal overload relay current range 10 16 a trip class 10a reset mode manual automatic auxiliary contact 1 no 1 nc rated insulation voltage ui 690 v mounting direct mount to siemens 3tf30 31 contactors or separate base protection of motors against overload phase failure and unbalanced load standards iec 6094741 thermal overload relay swas , siemens 3th30 220a auxiliary contactor relay make siemens model 3th30 220a type auxiliary contactor relay contacts 4 2no 2nc rated operational current ie 10 a ac15 4 a at 230 v 2 a at 400 v rated insulation voltage ui 690 v coil voltage 110 v ac 50 60 hz standard compliance iec 6094751 mounting din rail or panel mounting , semiconductor fuse rating 10a size 000 make siemens , semiconductor fuse rating 2a size 000 make siemens , semiconductor fuse rating 4a size 000 make siemens , semiconductor fuse rating 6a size 000 make siemens , auxiliary contactor coil dc with 2no 2nc contacts model 3th30 22 0bb4 siemens , motor protection with overload relay function mpcb biasing damper 24vdc motor protection circuit breaker size s00 with overload relay model 3rv2111 1da10 overload release setting 22 32 a short circuit release 42 a size s00 function motor protection w overload relay connection type screw terminal screw terminal suitable motor 400v 11 kw biasing damper 24vdc , type 3 pole contactor model 3ts30 100a make siemens specifications type 3 pole contactor coil voltage 230v ac power rating at 415v 4 kw approx auxiliary contact 1 no rating ac1 25 a ac3 9 a utilization category standard ac3 duty motor application up to 4 kw 415v 3 phase3 power contactor higher rating mcb swas make siemens , type 3 pole power contactor make siemens series sirius model 3rt2015 2ab01 coil voltage 24v ac 5060 hz utilization category ac1 18 a ac3 7 a rated voltage up to 690 v motor rating ac3 1point 5 kw 230v 3 kw 400v 4 kw 690v auxiliary contact 1 no 1314 built in terminals main 1l1 3l2 5l3 2t1 4t2 6t3 coil a1 a2 mounting din rail panel standard iecen 60947 41 power contactor silo , motor starter protector mpcb silo motor protection circuit breaker size s00 model 3rv2011 1aa10 standard mpcb size s00 trip function thermal magnetic main application simple motor switching protection connection type screw terminal screw terminal number of poles 3 adjustment range current 1point 1 to 1point 6 a instantaneous release magnetic 21 a trip class 10 operational voltage 20 to 690 v ac insulation voltage 690 v ac surge voltage resistance 6 kv mains frequency 5060 hz mpcb silo , type 3 pole contactor model 3ts30 100a make siemens specifications type 3 pole contactor coil voltage 230v ac power rating at 415v 4 kw approx auxiliary contact 1 no rating ac1 25 a ac3 9 a utilization category standard ac3 duty motor application up to 4 kw 415v 3 phase3 power contactor higher rating swas make siemens , thermal overload relay model 3us50 001k8k current range 8 12point 5 a tolr swas co ordination type 2 25a type 3na make siemens , add on auxialiry c

CTN :45616464 Due date: 26 Jun, 202626 Jun, 2026 NA
Tender For supply of industrial socket/receptacle as per following specification : 1) category: low voltage; 2) polesdescription: 3p+n+e; 3) shape: angled 20 degree inclination; 4) mounting mode: panel mounted, 5) rated current: 125amp; 6) rated operational voltage: 380 to 415v ac; 7) frequency: 50/60hz; 8) degree of protection: ip 67; 9) plug housing material: self extinguishing engineering polymer; 10) contact material: stainless steel springs, nickel plated brass sleeves, stainless steel pin; 11) standards: iec:60309-2 . make : jaibalaji/mv electrosystems/ garo or exactly equivalent in all dimension and rating. [ warranty period: 30 months after the date of delivery ] ]
 Loading, Please wait...

Connect us via What's Up