Get complete information related to latest Annunciation Relay Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Annunciation Relay Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Annunciation Relay Tenders.
Tender For corrigendum : provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate nu
Tender For auction sale of depot miscellaneous scrap - scrap panel board, panel, data logger, esab panel, relay rack, junction box, hp power panel, electrical boxes, ips set panel,rr/erru,rlt panel,lt disturibution panel,pump panel off size,ats panel,indication panel,amf panel, emergency battery charger, voltage regulator battery panel,and other panel with or withour wire / cable etc. old used and u.s. [loading by purchaser]
Tender For supply, installation, testing and commissioning of 11kv vcb panel board (12kv 1250a 25ka with over current fault earth fault relays iec61850 mimic diagram voltmeter ammeter annunciation windows with annunciationrelays 3 phase trivector meter 5amps dlms complaint with rs485 peernia rs
Tender For geafu-40/2026-27 repair/ maintenance of d.g set/amf panel/auto transformer switch/ contactor/ relay/ changeover switches/ control panel of diesel generator set and certain miscellaneous work at af stn nathatop under ge (af) udhampur
Tender For stage contract for supply of key materials required for maintenance of 33/11kv receiving stations along with their lines under the jurisdiction of std bijbehara during the year 2026-27 - electrical store/workshop items/: as per is standards, 11 kv vcb panel board 12 kv, 1250a, 25 ka, outdoor (incommer) as per technical specifications of rec std, 11 kv vcb panel board 12 kv, 1250a, 25 ka, outdoor (outgoing) as per technical specifications of rec std, 33 kv vcb (36 kv, 1250a, 26.2 ka, outdoor type) as per technical specifications of rec std, 33 kv c&r panel with nemurical relays with differential relay ( iec 61850), voltmeter, ammeter, annunciation windows with annunciationrelays, 3-phase tri-vector meter -5 amps, dlms compliant as per technical specifications of rec std, 33 kv c&r panel with nemurical relays with out differential relay ( iec 61850), voltmeter, ammeter, annunciation windows with annunciationrelays, 3-phase tri-vector meter -5 amps, dlms compliant as per technical specifications of rec std, 33 kv isolator with earthing blade (36kv,1250a, outdoor, 3 poles, 25 ka), 33 kv isolator without earthing blade (36kv,1250a, outdoor, 3 poles, 25 ka), 33 kv outdoor, oil cooled, live tank, single phase , 3 core ct set as per isi specification with accuracy class sp 10 for protection,0.5 for metering & ps for differential with ratio 800-400/5-5-5a ,600-300/5-5-5a , 500-250/5-5-5a, 400-200/5-5-5a (per set of 3 pieces), 33 kv outdoor, oil cooled, copper wound , single phase , pt set with rated primary voltage 33000/ 3 & rated secondary voltage 110/ 3 as per isi specification with accuracy class 0.5 (per set of 3 pieces)., 33 kv lightening arrestors (30 kv, 10ka, station class, zno, porcelain/polymer) gap less(per set of 3 pieces)., 33 kv post insulator (polymer/porcelain 36kv, 170kv impulse), galvanised steel structures(6" g i pipe with top,base & grouting bolts) as per rec, 11kv (e) grade armoured ,almunium,400 sq mm,3-core,xlpe power cable, (std make), 11kv (e) grade armoured ,almunium, 300 sq mm,3-core,xlpe power cable, (std make), 11kv (e) grade armoured ,almunium,240 sq mm,3-core,xlpe power cable, (std make), 11kv (e) grade armoured ,almunium, 185 sq mm,3-core,xlpe power cable, (std make), 11kv (e) grade armoured ,almunium, 120 sq mm,3-core,xlpe power cable, (std make), 2.5 sqmm 2 core control cable armored , copper conductor sheathed pvc insulated multi colour voltage grade 1.1 kv (std make), 2.5 sqmm 4 core control cable armored , copper conductor sheathed pvc insulated multi colour voltage grade 1.1 kv (std make), 2.5 sqmm 6 core control cable armored , copper conductor sheathed pvc insulated multi colour voltage grade 1.1 kv (std make), 2.5 sqmm 8 core control cable armored , copper conductor sheathed pvc insulated multi colour voltage grade 1.1 kv (std make), l t cable 3 1/2 16 sq.mm core armored , al conductor sheathed pvc insulated (std make), 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m or raychem make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 400sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 300sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 240sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 185sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 120sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for
Tender For bid to ras bid to ras supply of disconnecting and removing of all existing pmu control wiring , disconnecting and removing all existing control wiring in the old amf panel , supplying and fixing of amf controller , supplying and fixing of 4 pole 100 amps mccb , supplying and fixing of 63 amps 4 pole power contactor with addon block , supplying and fixing of push button switch for on off , supplying and fixing of 12v relay , supplying and fixing of 63 amps 4 pole 4 way with centre off rotary selector switch , supplying and fixing of 6 amp 3 way with centre off rotary selector switch , supplying and fixing of mechanical interlock suitable for 4 pole power contactor mcx 12 , supplying and fixing of 12v 10a smps type battery charger , supplying and fixing of 6a c series sp mcb , supplying and laying of 4 core 16 sq.mm pvc insulated al cable direct in ground , supplying and laying of 4 core 16 sq.mm pvc insulated al cable on surface of wall , supplying and laying of 4 core 16 sq.mm pvc insulated al cable in masnory open duct , supplying and making end termination with brass compression gland , supply and laying of 8 core 1.5 sq.mm copper conductor armoured control cable
Tender For corrigendum : comprehensive maint of dg sets with including replacement of fuel filter oil filter air filter calibration of nozzle system replacement of avr disply boad rewinding of alternators of different capacity maint of amf panel lt panel timer switch - comprehensive maint of dg sets with & including replacement of fuel filter, oil filter, air filter & calibration of nozzle system, replacement of avr, display board, rewinding of alternators of different capacity, maint of amf panel, lt panel, timer switch, relay contactor and other misc works in explosive/non explosive area of nad, tunir, abhimanyu and ammunition jetty at naval station karanja