Get complete information related to latest Annunciation Relay Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Annunciation Relay Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Annunciation Relay Tenders.
Tender For electrical material -relay. timer- siemens make electronic timer star delta cat no. - 3rp1576inm208k setting time range (3-60 sec.) rated voltage 380-440 v 50 hz 200-240 v 50 hz. overload relay type - c. t. operated bimetal relay with single phasing protection. relay range-(115-180 amp.) cat no. - 3ua6230-5b. overload relay range-(85-135 amp.). overload relay type - 3ua5830-50 range-(95-120 amp.). overload relay type - 3ua19-4 range-(70-110 amp.) contactor. kit. switch- siemens make auxiliary contactor type 2ty1301-of, 4 no. + 2 nc (42) auxiliary contactor type 3ty1 301-of, 3 no.+ spare main contact kit for contactor 3ta 16 spare main contact kit for contactor 3ta 24 spare main contact kit for contactor 3ta 28 spare main contact kit for contactor 3tf 47-7 spare main contact kit for contactor 3tf 50 spare main contact kit for contactor 3tf 52 spare coil for contactor 3tf 47-7 220/415 vac spare coil for contactor 3tf 50 220/415 vac spare coil for contactor 3tf 52 220/415 vac spare coil for contactor 3ta 28 220/415 vac
Tender For relay, plug in type, style "ac led" all aspects, ac lamp proving relay unit with in-built current transformer type, slow release neutral line relay, 4f. 4b contacts, front and back contacts metal to carbon, shall be suitable for working in series with the 110v ac , led signal lamp rated at 15w confirmingto rdso spec. sts/e/relays/ ac lit led signal/ 09-2002, amd-1 brs: 941a, irs: s 34 & irs: s 23 (as applicable). the interlocking code for this unit shall be abdhk". [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 0 %age , item category : normal , total po value variation permitted: max 8 lacs ] [ rate of supply 500 units per month , commencement time allowed -2 month ]
Tender For providing and replacement of damaged shaft encoder proximity sensors pressure switch define time reverse power numerical relay and nozzle graflon bush installed at baner power house under baner power house division hpsebl jia
Tender For relay, ac immune, plug in type, style qna1 , dc neutral line, 24v, 8f/8b or 12f/4b contacts, front and back contacts metal to carbon, with plug- board , retaining clip and connectors conforming to brs:931a, irs: s 60, irs: s 34 & irs: s 23 (as applicable). the interlocking code for this unit shall be abdgh or abdfh. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 0 %age , item category : normal , total po value variation permitted: max 8 lacs ] [ rate of supply 1000 units per month , commencement time allowed -2 month ]
Tender For corrigendum : procurement of electrical items for bluestar make chiller ntpc khargone - power contr,siemens,3ts5522oap028k, contactor,siemens,3ts5122-0an2, contactor: power,3ts50220ap008k,siemens, power contr,siemens,3ts4922-0ap0-08k, contactor: pwr cont,230vac,50a,3, relay: bimetal,70-95a,440v,1no+1nc, time delay relay,3rp1576-1np30,siemens, relay: time,3a&1a,0.85-1.1,1-20s,3rp15+, power contr,siemens,3ts3010-0ap0-08k, power contr,siemens,3ts3210-0ap0-08k, sfu,siemens,3kl8311-3aj00, sdfu,siemens,3kl8231-3aj00, sfu,normal duty-tp,415v,315a,siemens
Tender For supply of supply of 6 a sp mcb , supply of 10 a sp mcb , supply of 16 a sp mcb , supply of 20 a sp mcb , supply of 25 a sp mcb , supply of 32 a sp mcb , supply of 20 a dp mcb , supply of 20 a tp mcb , supply of 40 a fp mcb , supply of 63 a fp mcb , supply of 125a four pole fp mccb , supply of 200a four-pole fp mccb , supply of 40 a, double pole, rccb , supply of 63 a four pole mccb , supply of four pole, ac1 rating 40a , contactor , supply of three pole ac3, 32a rating contactor , supply of under current monitoring relay , supply of 3-pole power contactor with add on block , supply of thermal overload relay , supply of rotary operating direct handle for mccb , supply of rotary operating extended handle for mccb , supply of 06 way double door db , supply of weather proof frp junction box , supply of copper flexible cable 2c x 1.5 sq.mm , supply of copper flexible cable 3c x 1.5 sq.mm , supply of copper flexible cable 3c x 2.5 sq.mm , supply of 4 c x 10 sq.mm xlpe armoured aluminium cable , supply of frlsh single core copper conductor 1.5 sqmm , supply of frlsh single core copper conductor 2.5 sqmm , supply of frlsh single core copper conductor 4 sqmm , supply of frlsh single core copper conductor 6 sqmm , supply of heat shrink straight through joint kit for 3.5 core 95 sqmm , supply of 4 feet, 20w energy efficient led batten light fitting , supply of 9w led bulb with b22 base , supply of 20w led bulb with b22 base , supply of square type 36 w led down light , supply of 50 w led fllod light , supply of 70 w led street light , supply of 1200 mm sweep five star rated bldc fan , supply of 150 mm sweep exhaust fan , supply of 400mm sweep pedestal fan , supply of 300mm sweep wall fan , supply of 300 mm sweep table top type rechargeable fan , supply of 5 or 6 amp, 3 pin plug top , supply of 15 or 16 amp, 3 pin plug top , supply of automatic programmable analog time switch , supply of 3 phase digital multifunction meter , supply of flush-mounted analog panel type ammeter , supply of flush-mounted analog panel type voltmeter , supply of panel mounting red pilot light , supply of panel mounting green pilot light , supply of panel mounting yellow pilot light , supply of panel mountingf blue pilot light , supply of panel mounting amber pilot light , supply of connector din rail mounted for 2.5 sq. mm conductors , supply of connector din rail mounted for 25 sq. mm conductors , supply of mild steel din rail 1 mtr length , supply of 20w, 4 feet led tube light , supply of surface mountable, 15w led emergency lamp , supply of 1hp centrifugal pump single phase , supply of digital vernier caliper , supply of addressable photoelectric smoke detector for fire alarm system , supply of addressable zone interface module , supply of audio visual alarm device for addressable fire alarm system , supply of manual call point mcp for addressable fire alarm system , supply of 2 core 1.5 sqmm red fire alarm cable //bid details 2 / 53
Tender For supply of "ux. protection relay q-118 with jss/mil gr.electronics components timer and other requirement as per clw spec .no. clw/es/r-27, alt-z sr.no.1 of sheet-13/a off time delay relay type ct32.1/110v dc for q-118 application consisting of timing module ct32/dc110v r- 1 no., plug in relay c31w/dc110v s - 1 no., system socket s3m0 - no.,with base and mounting arrangement only as per clw specification no. clw/es/r-27z." [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of off time delay relay (type-re17rmmw) to spec. no. clw/es/3/0064 alt.c. [ warranty period: 30 months after the date of delivery ] ]
Tender For state plan- works under nedumkandam section-state plan 2024-25 - energy efficiency improvement, optimization of electromechanical items, safety audit and ensuring safety in operation of wtps and pump houses- rwss to udumbanchola - supply, e - cost of materials & working charges, od70149/2024-2025:1. pump & motor -supply, erection, testing and commissioning of kwa pre-qualified reputed make centrifugal pump set with bronze/ss impeller, ss shaft and ci pump casing etc. complete. the duty condition is as follows, discharge - 6 lps & total head - 92m, the motor is tefc squirrel cage induction motor suitable for the above pump working with 3 phase, 50 hz, 415 v shall confirm to eefi/is 325 etc. complete including providing suitable concrete foundation including cost of cement., sand and metal etc. flexible coupling shall be used for coupling of pumps and motors. 2. starter - supply, erection, testing and commissioning of suitable rating fullu automatic star delta starter with air break contact starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per ie rules and code of practice etc. complete. 3. panel board (suitable) for operating pump sets (but one pump set at a time) - supply, erection, testing and commissioning of cubical type floor mounted ms fabricated dust and vermin proof common control panel board consisting of 1 no. suitable capacity mccb as incomer and 2 nos of suitable capacity mccb as out going (the two mccbs are interlocking with each other) providing suitable size aluminium bus bar inter connect the above mccbs and fitted with 3 nos of indicator lamps, 1 no. volt meter with selector switch, 1 no. ammeter with selector switch etc. complete and provided with a common earth bus for the entire panel and inter connect with the mccbs as per ie rules and code of practice. the panel shall be fitted on a common base frame on suitable foundation. 4. cabling work - supply, laying, testing and commissioning of suitable size cables for the above pump set from panel board to starter and from starter to motor , considering energy conservation. 5 .earthing - supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing gi/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per ie standards. 6. capacitor - supply, erection, testing and commissioning of heavy duty app capacitor for the motor to get a power factor above 0.95. the capacitor shall confirm to is 2834 . 7. valves - supply of suitable size best quality heavy duty isi marked ci double flanged sluice valve and non return valve with suitable pressure rating 8. suction and delivery pipe connections - the size of the suction pipe is suitable as per the site condition with a max length of 7.5m. suitable size foot valve connecting at the suction pipe bottom etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.warranty 2 year (1 year warranty+ 1 year additional warranty), od109714/2024-2025:dismantling the existing old damged pump by disconnecting the cables, 15.2.1:demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in-charge.nominal concrete 1:3:6 or richer mix (i/c equivalent design mix), 4.3.1:centering and shuttering including strutting, propping etc. and removal of form work for:foundations, footings, bases for columns, 5.1.3:providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), 5.22.6:steel reinforcement for r.c.c work including straightening, cutting, bending, placing i