Get complete information related to latest Ats Panel Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ats Panel Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ats Panel Repair Tenders.
Tender For supply of eee lab items - furniture, 5hp/3.75kw/415v1500rpm three phase(3 )synchronous motor with starting / loading arrangement and with work bench voltage:415v ac/220v dc for field excitation make: benn rating: 5hp/ 3.75kw speed:1500rpm no of poles : 4 synchronous starter dc excitation field current :0.8a digital voltmeter ac(0-500v) moving iron type:01qty digital ammeter ac(0-20a) moving iron type :01qty digital ammeter dc(0-2a) moving coil type :01qty digital power factor meter 600v/10a :01qty 3pole mcb/dc mcb with 20a fuse carrier and supply indicators (three pin plug socket should also be provided) :03qty digital rpm indicator with proximity sensor: 01qty banana connectors for motor/starter/supply outputs :01qty control panel (hylem sheet(5*1.5feet) with ms panel) :01 work bench spec: size: 4feet*3feet*2 1/2 feet height leg teak wood with top 3/4" inch plywood 18mm plywood withone mica sheet for finishing front side cupboard with door open and closed type back side wiring box with door open and closed type, performance of ultrasonic and moisture sensors(5v dc/15ma(40khz/digital output) arduino uno: microcontroller-atmega328p on-board digital sensor components two push button switches and dour leds buck converter and relay for 5v and potentiometer-one each 2x16 liquid crystal oscillator(lcd) and mini bread-one each onboard digital sensor modules: ultrasonic sensor module(3cm-100cm) and soil moisture sensor -one each all sensor modules should be mounted on legend size pcb, speed control of ac motor using variable frequency drive(vfd) (0.5hp/415ac/5a(3 )) variable frequency driver (vfd) unit: input voltage:single phase, 230v ac +-10%, 50hz output voltage : three phase output frequency range: 0 to 60hz suitable for 0.75kw motor output current 4.2a vf pattern of spwm control 2pole mcb for on/off control of mains ac voltmeter, ammeter and speed indicator should be provided external stop/start and frequency control should be provided output terminals should be provided and must be brought out in front panel experimental board should be housed in a cabinet with suitable cover three phase induction motor motor type:squirrel cage |rating:0.5hp voltage rating :415v ac speed :1440rpm+-5% insulation : class b/f
Tender For battery charging and discharging panel (station/table):supply, creation, installation and commissioning of digital signal processing (dsp)controlled igbt based ac to dc rectification(converter) with active power factor correction with fine control on voltage regulation, ripple, thd and improved efficiency with re-generative feature suitable to provide float charging and boost charging of ni-cd batteries of 199ah/110v capacity & lead acid batteries of 75ah/110v capacity as per spec and as per enclosed drawing no. sig/cd/1750/mech/01 for proper maintenance and handling of batteries in battery room. [ warranty period: 30 months after the date of delivery ] ]
Tender For state plan- works under nedumkandam section-state plan 2024-25 - energy efficiency improvement, optimization of electromechanical items, safety audit and ensuring safety in operation of wtps and pump houses- rwss to udumbanchola - supply, e - cost of materials & working charges, od70149/2024-2025:1. pump & motor -supply, erection, testing and commissioning of kwa pre-qualified reputed make centrifugal pump set with bronze/ss impeller, ss shaft and ci pump casing etc. complete. the duty condition is as follows, discharge - 6 lps & total head - 92m, the motor is tefc squirrel cage induction motor suitable for the above pump working with 3 phase, 50 hz, 415 v shall confirm to eefi/is 325 etc. complete including providing suitable concrete foundation including cost of cement., sand and metal etc. flexible coupling shall be used for coupling of pumps and motors. 2. starter - supply, erection, testing and commissioning of suitable rating fullu automatic star delta starter with air break contact starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per ie rules and code of practice etc. complete. 3. panel board (suitable) for operating pump sets (but one pump set at a time) - supply, erection, testing and commissioning of cubical type floor mounted ms fabricated dust and vermin proof common control panel board consisting of 1 no. suitable capacity mccb as incomer and 2 nos of suitable capacity mccb as out going (the two mccbs are interlocking with each other) providing suitable size aluminium bus bar inter connect the above mccbs and fitted with 3 nos of indicator lamps, 1 no. volt meter with selector switch, 1 no. ammeter with selector switch etc. complete and provided with a common earth bus for the entire panel and inter connect with the mccbs as per ie rules and code of practice. the panel shall be fitted on a common base frame on suitable foundation. 4. cabling work - supply, laying, testing and commissioning of suitable size cables for the above pump set from panel board to starter and from starter to motor , considering energy conservation. 5 .earthing - supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing gi/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per ie standards. 6. capacitor - supply, erection, testing and commissioning of heavy duty app capacitor for the motor to get a power factor above 0.95. the capacitor shall confirm to is 2834 . 7. valves - supply of suitable size best quality heavy duty isi marked ci double flanged sluice valve and non return valve with suitable pressure rating 8. suction and delivery pipe connections - the size of the suction pipe is suitable as per the site condition with a max length of 7.5m. suitable size foot valve connecting at the suction pipe bottom etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main.warranty 2 year (1 year warranty+ 1 year additional warranty), od109714/2024-2025:dismantling the existing old damged pump by disconnecting the cables, 15.2.1:demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in-charge.nominal concrete 1:3:6 or richer mix (i/c equivalent design mix), 4.3.1:centering and shuttering including strutting, propping etc. and removal of form work for:foundations, footings, bases for columns, 5.1.3:providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), 5.22.6:steel reinforcement for r.c.c work including straightening, cutting, bending, placing i
Tender For for electrical and communication engineering department lab equipments are required as per new syllabus - upgradation of labarotariesece department, 8051 micro controller kit operating voltage: +5 v dc. flash memory: 4 kb (at89c51) / 8 kb (at89s52). ram: 128 bytes internal ram. 16 2 alphanumeric lcd display. push buttons / tactile switches. dip switches for digital input. inbuilt adc interface: ldr, potentiometer. inbuilt dac interface. inbuilt stepper motor driver with stepper motor. inbuilt dc motor driver with dc motor. 1 4 led array, 1 4 keypad, 1 relay. 1 buzzer, 16 2 lcd display, 1 pwm driver. 1 hardware interrupt key, inbuilt rtc. inbuilt eeprom and uart module. 4 7-segment display. supports both assembly and c language programming. pc interfaceable., single phase induction motor1 hp, 230 v ac, 1500 rpm with loading arrangement 1 no.voltmeter: (0 300) v ac, 96 96 mm with input terminals 1 no.ammeter: (0 10) a ac, 96 96 mm with input terminals 1 no.wattmeter: 2 kw, 96 96 mm with input terminals 1 no.power factor meter: 96 96 mm with input terminals 1 no.auto transformer: 0 300 v, 1 variac 1 no.mcb: 2-pole, 40 a / 230 v ac 1 no.digital rpm indicator with proximity sensor 1 no.aluminium brake drum: 230 mm diameter 1 no.spring balance: (0 25) kg 02 nos.circuit diagram printed on front panel with instruments and connecting terminals.motor and loading arrangement mounted on rigidchannel frame with anti-vibration mounting pads, m12 1.5 bolt & nut, 85 mm dia 4 nos.mild steel powder-coated electrical panel tablesetup., auto transformerinput: 230 240 v ac, 50 hz.output: variable (0 270) v ac.rating: 1 kva.insulation class: class f / class h.construction: copper winding with carbon brush arrangement.mounting: bench-top / panel type.protection: suitable fuse / overload protection., dth trainer kitpower supply: 200 v to 240 v ac, 50 hz. dish antenna: 1.5 ft aluminium steerable dish antenna.lnb (low noise block down converter): input frequency: ku-band. output frequency: 950 mhz to 1450 mhz. conversion gain: 65 db. noise temperature: 35 k (max).set-top box receiver in trainer form: if frequency: 70 mhz. video bandwidth: 50 hz to 5 mhz. video output level: 1 vpp at 75 load. video polarity: normal/inverted, switch selectable. audio subcarrier frequency:tunable from 5.0 mhz to 8.0 mhz. remote control provided. hdmi cable: 10 m. controls: channel selection. volume control. fault simulation: five built-in simulated faults for troubleshooting experiments. if signal disconnected. video output fault. audio mute fault. tuner misalignment. rf output interruption. pcb size: 15" 12" with multicolour section-wise block diagram.standard accessories: 1.5 ft dish antenna. lnb. trainer pcb. dish connecting wire. audio-video cable. user manual. acrylic cover. hardware materials for assembly of dish antenna. additional features: dth subscription connection with doordarshanfree channels., sim reader trainer kitpower supply: operates on 230 v ac 10%, 50 hz mains supply. built-in regulated smps power supply. operating dc supply: 5 v / 12 v with overload and short-circuit protection.sim card interface: supports gsm sim cards compatible with 2g / 3g / 4g / 5g networks. sim card read/write interface. supports sim card initialization, authentication, and communication functions. compatible with standard 6-pin / 8-pin sim card sockets.communication interface: usb 2.0 interface for pc communication. rs-232 serial communication interface. uart communication facility for embedded system interfacing.sim operating parameters: selectable sim clock frequencies: 3.579 mhz 7.159 mhz 14.318 mhz sim supply voltage selection facility. sim reset and activation control. supported protocols and standards: gsm etsi 07.07 and etsi 07.05 at command support. iso/iec 7816 smart card communication support. sim communication command monitoring facility. hardware features: on-board sim card socket. led indication for: power status sim detection reset activity data transmission/r
Tender For supply of bending machine conduit pipe , bus bar with brackets 1 mtr , cctv camera kit , ceiling fan coil winding machine , conduit pipe cutting and threading machines , control panel , digital multi meter , discrete component trainer , dmx controller 512 , ev charger home 1 phase input , ev charger 3 phase input , file half round 2nd cut 250 mm with handle , file round 2nd cut 150 mm with handle , knife switch dpdt fitted with fuse terminals 16 amp , knife switch tpdt fitted with fuse terminals 16 amp , ladder - tower 3 meters on tyre wheels - min 10ft - max. 30ft , lux meter lcd read out 0.05 to 7000 lumens with battery. , magnetic flux meter , mallet barwood , meter reading instrument mri , potential transformer 415 v, 50hz, pt ratio, 440v.110v,10va , power factor meter digital , primary current injection set , rcc pole with accessories , rechargeable battery 12v,100ah , rubber mat , single phase transformer , single phase variable auto transformer , smart meter 3 phase - smart energy meter , soft starter , solar dc pump 1 hp , solar panel with battery 18 watt , solar street light , solar traffic light , solid state solar base single phase energy meter , spanner d.e. set , tachometer analog type - 10000 rpm , three phase transformer , wheat stone bridge ) /bid number : gem/2026/b/7576252 * /dated: 27-05-2026 & & / bid document 1 / 40
Tender For supply, installation, testing and commissioning of phase wire and street light and vairious electrical equipment needed for implementation of budget announcement 2025-26 - providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in, led street light fixture with minimum lumen output 5600 lm, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgear is to be paid extra )(d)wiring between components within switchgear and incoming / outgoing cable shall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap-offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be point to point (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)floor mounted panel sh
Tender For nit 107 work of providing, fixing and installing of automatic power factor control panel (apfc) for the period of 5 years under the jurisdiction of executive engineer, phed division paota
Tender For battery charger and discharging panel : "supply and commissioning of digital signal processing (dsp) controlled igbt based ac to dc rectification (converter) with active power factor correction with fine control on voltage regulation, ripple, thd and improved efficiency with re-generative feature suitable to provide float charging and boost charging of ni=cd battery 199ah/110v capacity.the technical specifications are as per enclosed annexure. [ warranty period: 30 months after the date of delivery ] ]
Tender For nit 07 work of providing, fixing & installing of automatic power factor control panel (apfc) for the period of 5 years panels under the jurisdiction of executive engineer, phed division paota