Get complete information related to latest Auto Switch Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Auto Switch Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Auto Switch Tenders.
Tender For corrigendum : purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp freque
Tender For supply of 1.compact flourescent light fitting single without 4 pin 11 w cfl lamp & electronic ballast. the fitting is to be provided with holder. the complete fitting shall confirming to rcf drawing no. cc 76215 alt-d.2.fitting side lamp complete, suitable for passenger brakes van, confirming to rdso drg. no.skel- 4094 with alteration -a. the colour convention of side lamp fitting is out side black colour and inside white colour. the fitting shall be supplied without lamp/bulb.3.night light fitting icf drg. no. icf/s.k. 7-6-020 col .iii alt. 'm' or latest for screw type lamp (without lamp).4.alarm chain pull indication light fitting conforming to rdso drg no skel-3911 [rev-1]alt-c with the following requirments [1]the outside of light fitting should be finished in synthetic enamel red paint to is 2932[2] the lens shall be clear and colourless [as per item -4 of rdso drg no skel3911] [3] holder shall be screw type e-27 [4] the cable entry hole shall be 20 mm dia instead of 11 mm dia.indicated in the drawing [5] holes shall be provided to suit 20 mm dia grommets.5.led foot light as per following details:- i) power: 4 watt. ii) input voltage range: 90-140v dc. iii) light colour: warm white. iv) color temperature: 3000k. v) ligh source: high efficiency long life smd led. vi)material: aluminium die cast. vii) finish type: powder coated. viii) shed colour: white. ix) mounting: wall mount. x) installation type: flush mount. xi) switch: no. xii) product dimention: a) length: 85 x 5mm.b) width: 85?5mm. c) height: 30?5mm. xii) cut-out(c): 70 x 70mm. xiii) indoor/outdoor usage: indoor. xiv) lighting method: down light. make : similar to victoria brand, model no. vlfl4.
Tender For corrigendum : supply of battery connector 350 e1102 , foot pedal e1509 , coil spring 402040001 , main contactor 80 v dc ksw 180 b e1092 , bch make foot switch fsgx1 e1111 , brake pad p n kc m 090 kc m 090 s , head light assy e10264t , dc to dc convertor ip 72 96 v op 24 e1197 , contactor dc 182 f r 80 v p no 132233 e1094 , brake liner p1271c , head light assembly 24 v dc e10263t , pin disc brake 375070009 , oil seal 80 100 12 , circlip dia 90x93x5x2 65 , oil seal 70 90 10 , coil spring 375040001 , disc brake assembly kcm090
Tender For corrigendum : e-tender for procurement o surgical instrument for different health institution - name of the item with specification, adrenalectomy gall badder forceps,265mm, adson periosteal elevators chisel -edge width 8mm,165mm(98 litres), adson periosteal elevators sharp width-5mm,165mm, air rotor hand piece, atraumatic fixation and dissecting forceps 5mmx220mm, atraumatic fixation and dissecting forceps 5mmx310mm, atraumatic fixation and dissecting forceps 5mmx420mm, allis atraumatic tissue grasping forceps straight 5mmx310mm, allis tissue grasping forceps 150mm, allis tissue grasping forceps 180mm, allis tissue grasping forceps atraumatic jaw,200mmchamber, allis tissue grasping forceps atraumatic jaw,150mm, allis tissue grasping forceps atraumatic jaw,180mm, allis traumanil jaw tissue forceps,255mm, airway (metalic)size(0-4)set of 5,230mm, ambubag(siliconised)adult and paediatric with accessories, amputation set, american pattem suction tip with stillet,size:3, american pattem suction tip with stillet,size:4, artery forcep 8"(straight), artery forcep 8"(curved), auto b.p calf, artery forcep toothted, artery forcep plain, artery forcep small, ash ureter forceps with araumatic jaw,240mm, ayre cone knives for ring biopsy-230mm, babcock tissue grasping forcep 180mm, babcock tissue grasping forcep 200mm, babcock tissue grasping forcep 150mm, babcock tissue grasping forcep 10mmx310mm, babcock tissue grasping forcep 10mmx370mm, bandage cutting scissor, b.p handle no 3 long, b.p handle no 4 long, b.p handle no.4, b.p handle,200mm no.8, boycles apparatos, braun obstetrical forceps,305mm, boyer craniotomy forceps slightly curved-290mm, bozemann uretine dressing forceps straight 230mm, bozemann uterine dressing forceps with longitudinal groove-250, castroviejo needle holder with catch t/c tip,180mm, cusco vaginal specullam small,90mmx25mm, cord clamp, d & c set, davis boyels mouth gag. 5 tongue blades, davis boyels mouth gag with anaes tube , 5 tongue blades, debakey needle holder standard t/c tip,250mm, defibrillator specification a) biphasic low energy current based b) 4ed mode as well as manual defibrillation and pacing . c) wide range of energy selection 1 to 200 joules.d) must have synchronized cardio version capability .e) 3 lead ecg monitoring f) adult and pediatric padles, g) >5" colour display. h) ecg analysis system. i) light weight j) lithium battery with functioning for >2 hrs after charging.k) iso/ce certified, doyens mouth gag.100 mm, dressing scissors sharp x sharp straight 180 mm, dressing scissors sharp x sharp curved 180 mm, dressing scissors sharp x blunt straight 125 mm, dressing scissors sharp x blunt straight 180mm, dressing scissors sharp x blunt curved 180mm, deavers abdominal retractor adult 12mm,300mm, deavers abdominal retractor adult 25mm,300mm, deavers abdominal retractor adult 15mm,300mm, deavers abdominal retractor adult 50mm,300mm, deavers abdominal retractor adult 38mm,300mm, deavers abdominal retracror adult 75mm,300mm, desjardins gall bladder forceps,225mm, desjardins gall bladder forceps,240 mm, doyens retractor 40mm x60mm,230mm, delivery set, episiotomy scissor, electric cautery machine,specification no of bipolar modes available:2 bipoler current meter: yes power efficiency :98 or more available of advance cutting modes for skin incision type of display :led no of segments of display:7 warrenty (option of comprehensive warranty is available through bidding only,which if opted will supersede normal warranty in the catalogue):3 or more monoplolar foot switch supplied :1 bipolar foot switch :1 hand swithcing pencil:reusable patient plate: reusable bipolar forceps:1 forceps cord:1 universal adoptor :1 type of output of elctro surgical generator monopolar and biopolar outputs designed for all surgical procedure including general surgery,gynecology ,minimal invasive surgery,orthopaedic and oral surgery machine should be able ot monior changes in tissue impedance continuously and adjusts power :yes