Tender For minutes of pre-bid meeting - supply, installation, testing and commissioning (sitc) of 04 nos. of automaticboombarrier system at the entrance of three residential colonies of rbi kanpur
Tender For complete audio visual set up at conference room ghandhi bhavan first floor braiprd - wireless handheld mic (make bosch/ yamaha/ harman/ sennheiser/ beyerdynamic/ meyer-audio/ bose), microphone capsule(make- bosch/ yamaha/ harman/ sennheiser/ beyerdynamic/ meyer-audio/bose), wireless lavalier / headset system (make- bosch/ yamaha/ harman/ sennheiser/ beyerdynamic/ meyer-audio/ bose), headset - headmic with cardioid capsule to use with wireless systems (make- bosch/ yamaha/ harman/ sennheiser/ beyerdynamic/ meyer-audio/ bose), lavalier -cardioid lavalier microphone (make- bosch/ yamaha/ harman/ sennheiser/ beyerdynamic/ meyer-audio/ bose), 2 way, bass reflex type surface mount speakers with superior sound quality. components: lf: 5.25"cone driver; hf: 0.75" soft dome; frequency range (-10db): 62hz - 20khz; nominal coverage: h x v: 120 x 120 ; crossover: 3khz; power rating: 150w pgm; transformer taps: 30w, 15w, 7.5w @ 100v; sensitivity (1w; 1m on axis): 89db spl; peak: 114db spl; cabinet material: abs; waterproof rating: ip35; color- black (make- bosch/yamaha/harman/sennheiser/beyerdynamic/meyer-audio/bose), amplifier -wide range of power amplifier from 480w.multiple outputs 70 v / 100 v and 8/4 ohm.temperature controlled forced front to backventilation, directly stackable.mains, battery back-up, and pilot tone supervision.(make- bosch/yamaha/harman/sennheiser/beyerdynamic/meyer-audio/bose), mixer -16-channel mixing console: max. 10 mic / 16 line inputs (8 mono + 4 stereo) / 4 group buses + 1 stereo bus / 4 aux (incl. fx)16-channel mixing consolemax. 10 mic / 16 line inputs (8 mono + 4 stereo)4 group buses + 1 stereo bus4 aux (incl. fx) d-pre mic preamps with an inverted darlington circuit 1-knob compressorshigh-grade effects: spx with 24 programs24-bit/192khz 2in/2out usb audio functionsworks with the ipad (2 or later) through the apple ipad camera connection kit / lightning to usb camera adapter includes cubase ai daw software download versionpad switch on mono inputs+48v phantom powerxlr balanced outputsinternal universal power supply for world-wide userack mount kit includedmetal chassis (make- bosch/yamaha/harman/sennheiser/beyerdynamic/meyer-audio/bose), 12x zoom hd ptz video conference camera (make-clearone/liverty-ad/lumens), interactive display 86" (make-samsung/sony/christie), 55" display (make-samsung/sony/christie), 43" display (make-samsung/sony/christie), digital podium (make- aha/globus/uni/atdsc)metallic frame, stand-alone, wheels with locksmooth round edge at the toptray for keyboardsingle sliding tray with lock for protection of the interactive panel and portsspace for 19 or 22 interactive panel with motorized angle adjustmentdrawer with lock, shelf for keeping laptop or documentslocks for safety, standard rack to keep all the equipment and pc, 19 rack for storing equipmenttwo door system one in front and one in back, front door for servicinghdmi x 1, usb x 1, 1 x power socket, rj 45 x 1., 15u floor mount 600*600 rack with accessories (make-apw/val/netrack), desktop pc core-i5/ssd/8gb ram/win-11 (make- hp/dell/lenovo), accessories including ,hdmi cable,speaker cable,usb cable ,splitter,hdmi switcher, connector, tv mounting kit etc., installation,commisioning and configuration
Tender For supply, installation, testing and commissioning (sitc) of 04 nos. of automaticboombarrier system at the entrance of three residential colonies of rbi kanpur
Tender For corrigendum : supply of cctv camera , boombarrier for main gate , automaticboombarrier gate , torch light , metal detector , walk through metal detector , search light
Tender For bid to ras corrigendum : supply of rocker fork etc e e - rocker fork for 2650t press as per drawing 01 05 130 , thread coupling as per drawing 01 05 005 r2 item no 1 to 4 , lifting rod as per drawing 01 05 236 , mu 25 valve cone for 2650t press as per drawing 01 05 237 sheet 1 , mu 25 valve seat for 2650t press as per drawing 01 05 237 sheet 2 , h c clamp 12 inch copper insert as per drawing 02 01 008 r5 , lift rod of drive system as per drawing 021 01 172 sheet 4 of 9 , rod end of drive system as per drawing 021 01 172 sheet 3 of 9 , screw fitting of drive system as per drawing 021 01 172 sheet 01 of 9 , safety plate of drive system as per drawing 021 01 172 sheet 7 of 9 , guide of drive system as per drawing 021 01 172 sheet 2 of 9 , bushing and ring item no 1 and 2 of drive system as per drawing 021 01 172 sheet 6 of 9 , bolt of drive system as per drawing 021 01 172 sheet 9 of 9 , ball socket of drive system as per drawing 021 01 172 sheet 5 of 9
Tender For corrigendum : purchase of sports physiotherpy lab equipments - focused shockwave therapy the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touch screen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high laser therapy should be class iv high level laser therapy system should have a real-time operating system technology should have maximum laser should be class iv high level laser therapy system should have a real-time operating system technology should have maximum laser power output of 15 watts should have wavelengths of 810 nm & 980 nm should have an aiming beam of 650nm, should have 2 operating modes: continuous wave or pulsed applicate and piece should have embedded finger switch and light, should have a technology to customize patient treatment based on conditions, body area, body type, skin type, chronicity and absorption characteristics applicator should have a fused silica composition massage ball at the point of contact of applicator and skin. pulse frequency: 2, 10, 20, 100, 200, 500, 1000, 2500, 5000 & 10000hz pulse duration: 50% duty cycle at any given pulse frequency setting, should have a 10 hd display touch screen with password protection to reach the home screen should be supplied with 2nos. of laser protection glasses power: 100-240v, 50-60 hz the unit should be supplied with 5 different types and sizes of treatment heads (large cone, large massage ball, flat window, small massage ball, and small cone. the unit should have inbuilt battery. electrical safety class: class i, type b weight should not exceed 4 kilograms (main unit; without applicators & accessories. must have class iii also., combination therapy machine with vaccum should have 3 independent electrotherapy channels, one ultrasound channel should provide multiple clinical waveforms including interferential (2 and 4 poles and isoplanarvector), tens (asymmetric biphasic &symmetric biphasic), han, russian, vms, surged(rectangular &triangular), hvpc, microcurrent, galvanic (continuous, interrupted and low level),rabert & dia dynamic cpid/cpiso should have independent parameter adjustments for each channel including intensity, frequency, duty cycle, vector scan, channel mode, phase duration, ramp, cycle time and treatment time based on waveform should have maximum output intensity up to 140ma should have constant current and constant voltage modes should have 2 colour coded lead wires for easy picking of selected channels should have suggested electrode placement guidelines ultrasound should offer 1 and 3 mhz frequencies should have the ultrasound bnr of 5:1 or lesser should be supplied with one 5cm applicator head should have pulsed & continuous frequency modes (10%, 20%, 50% & 100%) should have variable duty cycles of 16 hz, 48 hz &1 bb 00 hz should have facility to indicate applicator uncoupling should be able to use electrotherapy and ultrasound independently and also in synchronizedcombination of electrotherapy and ultrasound, where ultrasound head functioning as bothultrasound head and electrode should have minimum
Tender For supplying and fixing of 02 nos. automaticboombarrier facility alongwith civil works for newly proposed level crossing lc-2 in sipat stageiii area