Get complete information related to latest Bus Bars Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bus Bars Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bus Bars Tenders.
Tender For supply of sg4935117150-numerical teed protection relay _process bus_ as per it-18 of ann-1 , 19- sg4935117168-metrosil as per it-19 of ann-1. , 20- sg4935117176-stabilising resistor _0-5k_ as per it-20 of ann-1 , 21-sg4935117184-numerical busbar protection process bus _new switchyard in present scope_ as per it-21 of ann-1 uom-set , 22- sg4935117192-bay control unit _process bus_ as per it-22 of ann-1 , 23-sg4935117206-panel along with merging unit _and_ switchgear control unit _process bus_ as per it-23 of ann-1 uom-set , 24- sg4935117214-ethernet switch _process bus_ as per it-24 of ann-1 , 25-sg4935117222- gateway_slash_networking panel as per it-25 of ann- 1 , 26-sg4935117230-ows _ccr_ as per it-26 of ann-1 uom-set , 27-sg4935117397-ews _cer_plus_crp_plus_ccr_ as per it-27 of ann-1 uom-set , 28-sg4935117249-laptop _scr_plus_ex_ as per it-28 of ann-1 , 29-sg4935117400-a4 printer _cer_plus_crp_plus_ccr_ as per it-29 of ann-1 , 30- sg4935117257-ows _scr_plus_ex_ as per it-30 of ann-1 uom-set , 31-sg4935117265-ews _scr_plus_ex_ as per it- 31 of ann-1 uom-set , 32-sg4935117273-a3 printer _scr_plus_ex_ as per it-32 of ann-1 , 33-sg4935117281- a4 printer _scr_plus_ex_ as per it-33 of ann-1 , 34- sg4935117370-dot matrix printer _scr_plus_ex_ as per it-34 of ann-1 , 35-sg4935117290-laptop _scr_plus_ex_ as per it-35 of ann-1 , 36-sg4935117303- 80 inch rear projection lvs as per it-36 of ann-1 uom- set , 37-sg4935117311-inverter as per it-37 of ann-1 uom-set , 38-sg4935117320-network firewall as per it-38 of ann-1 uom-set , 39-sg4935114002-fo cable _in mtrs_ as per it-39 of ann-1 uom-meters , 40- sg4935117338-control room furniture as per it-40 of ann-1 uom-set , 41-sg4935117346-sas spares as per it-41 of ann-1 uom-set , 42-sg4935117354-training as per it-42 of ann-1 uom-set , 43-sg4935117389-amc as per it-43 of ann-1 uom-set
Tender For electric cabling service - 3 phase heavy duty electric wiring xlpe insulated working voltage form 415 v to 11 kv as per is 1554 along with associated items and civil work as per schedule of work attached; copper and aluminium coth conductor material as per schedule of work-1 supply, laying and testing cable xlpe insulated ,screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sq mm 3 1/2 core. rm 280 2 excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, or for shafts, wells, cesspits, manholes, pier holes, etc. and not exceeding 10 sqm on plan and getting out in soft /loose soil complete all as specified and as directed cum 60.75 3 returning filling including spreading leveling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and as directed. cum 60.22 4 removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. cum 0.53 5 supply and laying ldpe pipes 50 mm dia with all fitting ,laid in ground for crossing the cables across the road by cutting existing road , under floor ,wall by cutting existing floor and making good the road /floor and wall surface after laying of pipe . rm 270 6 cement concrete 1:3:6 type c-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete for making foundation for mounting flood light /bollard light fitting/finishing of roads/floors etc . cum 4.05 7 m &l for cutting of road /floor surface 30cm girth, up 45 cm width for croosing the pipe line /laying of cable acroos the road all as specified and directed. rm 30 8 s & f distribution boards epoxy powder coated tp & n (vtpn mccb db) 8 way ,415 volts ,fabricated from minimum 1.6 mm thick crca sheet and fixed/ flush to wall and suitable for universal mounting with 250 amps fully insulated copper bus bar for each phase and 02 neutral shrouded bar ,2 earth bar and cable tie for cable management with reversible door for ip-43 db,s protection, suitable for fixing fp mccb 100/125 amps as incomer complete all as specified and directed. note: suitable mccb and outgoing mcbs will be measured separately under relevant items of this schedule each 1 9 s & f mccb ,4 pole 100 a , 415 volts with rupturing capacity 16 ka with thermal-magnetic release and adjustable overload setting of following capacity complete all as directed. each 1 10 s & f bus bar chamber with 4 nos copper busbar 150 amps including mccb 100a 16ka 415 volts each 1 11 s & f sub main wiring with 4x16 sqmm +1 x 10 sqmm run pvc insulated unsheathed frlsh cable 1100 volt grade, with multi stranded copper conductor drawing in concealed pvc conduit not less than 25mm dia complete all as specified and directed. rm 50 12 s & f sub main wiring with 2x4 sqmm +1 x 4 sqmm run pvc insulated unsheathed frlsh cable 1100 volt grade, with multi stranded copper conductor drawing in concealed pvc conduit not less than 25mm dia complete all as specified and directed. rm 200 13 s & f modular rectangular block for mounting,modular switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175mm x 175 mm and 50 mm deep each 25 14 supply and fix modular switch 1 way 16a, 1 module with indicator lamp each 25 15 supply and fix modular socket 6a/16a, 2/3 pin combined 2 module each 25 16 material and labour for earthing with galvanised steel earth plate electrode 60cmx60cmx 6mm thick burried directly in ground (earth pit not less than2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 32 x 6 gi strip by means of nuts,bolts,check nuts & washers of galvanized iron or steel,protected by 15mm bore light grade galvanised iron pipe and connected to
Tender For corrigendum : supply of droppers and busbar sets of bhel make ht switchgear - bus connection set,bhel,cb,11kv , bus bar connection,35216602010,bhel , bus bar connection,35216601865,bhel , bus bar conn set ryb,35216602601,bhel , bus bar,12x200cu,bhel,vac cb,11kv , bus bar,25216901502-v01,12x200,al,bhel , busbar,35216901507-v00,12x100,al,bhel , dropper b or w bb,bhel,vcb , dropper b or w bb,35216301651- v02,bhel,vcb , dropper,bb and sf,bhel,cb,11kv
Tender For providing and installation of electrical accessories and allieds works at shaspur pwss, block-rampurhat-ii under bolpur mechanical division - supply, delivery at site and storage of wall mounted made of sheet steel fabricated 2 mm for load bearing & 1.6mm for non load bearing, indoor type, dust & vermin proof, lp-54 degree of protection, powder coated painted with rubber gaskets cover, front lockable hinged door with all switchgear and other items duly wired up and tested as per specification: incomer: (a) 100 amps, tpn mccb with adjustable ol, 36 ka, e/f, auto phase corrector & necessary accessories with suitable spd (i.e., ammeter, voltmeter, cts & switches), outgoing:- (b) 7.5 hp to 12.5 hp, tp star-delta starter with other accessories - 1 nos., (suitable size capacitor bank to improve pf from o.85 to 0.98) (c) yard lighting feeder with necessary accessories & time switch(digital) - 1 no. (d) 3phase actuator valve starter with other accessories -1 nos., (e) 2 hp ,3 ph,415v,clorinator feeder with necessary accessories & level controller-1 no., (f) 32a mccb fdr for iep/misc purpose-1no., (g) 32a mccb for in house light-1no.,(e) plc feeder with necessary accessories-1no.( all spare & components as per vendor list of phed), supply and delivery at site of 15 kva, 3phase, oil cooled type servo motor operated copper wound line voltage corrector conforming to is-9815 (pt.-1)- 1994 suitable for un-balanced input voltage with following specification including first filling oil as per is-335 where applicable.a) input voltage:- 3 phase, main supply may or may not be balanced with respect to phase to phase- 200v-500v phase to neutral-115v-290v.b) output voltage:-3 phase balanced output voltage. phase to phase- 400vor 415v 1%, phase to neutral- 230v-240v 1% (provision should be made to adjust the variation of output voltage per phase by a variable pot oil within 5% of output).c) line regulation:- out put voltage should remain well with 1% of set voltage (from minimum to maximum i.e. either 400v. or 415v. supply variation).d) load regulation : output voltage should remain neutral well within 1% of set voltage be ( from no load to full load ) i.e. either 400v. or 415v.e) correction speed:- better than 35 volt / second.f) efficiency:- better than 95% on full load.g) cut off limit (minimum &maximum ) by limit switch with audio & visual.h) metering indication:- by selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available.i) lamp indication :- for input & output should be provided. ( 3 lamps per side ).j) mcb protection: for input side.k) load protection : hrc fuse on each output phase should be availablel) output over shoot:- beyond 210v to . 255v /phase in case of manual mode & voltage protection :auto mode operation.m) visual indication for under voltage & over voltage of output.n) manual mode:- up & down correction with o / p voltage over shoot protection. beyond 210 v-255 v. per phase.o) nature of cooling:- oil cooled system.p) electric current over load protection .q) circuit for delay output .r) input high voltage cut-off above 500 v.s) mode of operation:- auto/manual with a provision to restore the normal working of the unit standby operation should be available in case of any electronic failure in auto mode., installation of mcc panel along with main switch, changeover, busbar chamber, cut out etc. all electrical equipment within the pump house, drawing of cable properly on suitable size gi cable tray on wall / as per direction of eic as per layout & ie rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fixing of materials for taking power within the pump house from wbsedcl end as per direction of eic. [for ph no - i, ii & iii], installation of above supplied stab
Tender For providing and installation of electro-mechanical accessories at cwr site and allieds works at ekpara pwss, block-rampurhat-i under bolpur mechanical division - supply and delivery of openwell submersible pumping machinery set suitable for wet pit installation complete with stainer along with all accessories with following specification: pump : discharge (q) : (1800-1280) m3/hr. & head (h) : (19-38) mtrs.method of starting : sd, shaft-stainless steel-ss-304, impeller- crome steel/ci/s.s / bronze, suc & del size- 90/80 mm dia, type of position-horizontal. mechanical sealmotor : 12.5hp (suitable for open well)operating voltage : 415 ( 10 %), phase : 3ph, 50 hz 6%speed : 2800 rpm, method of starting : s/dmake : ksb / grundfos / texmo / cri / kbl / mbh / or any approved vendor. ( n.b : manufacturers test certificate along with charecteristics curve, moc and gurantee certyificate have to be submitted at the time of delivery.), supply & delivery at site of 35 mm x 3.5 core size aluminum armored, xlpe insulated 1.1 k.v. grade cable, conforming to is 7098(i) as per direction of eic.(make:- gloster / polycab / mescab / or any approved vendor list of phed.) ( n.b : manufacturers test certificate have to be submitted at the time of delivery.), supply & delivery of 100a kit-kat rewireable (porcelain fuse carrier & base) (make:- havells / l&t / or any approved vendor list of phed.), supply & delivery of 100 amps re-wireable porcelain fuse unit type tpn main switch with steel sheet enclosure (conforms: is/iec600947-1&3). (make: havells /approved vendor list of phed.), supply & delivery of re-wireable type tpn changeover switch 100 amps 415v, 50hz, 4 pole offload with steel sheet enclosure (conforms: is/iec60947-1&3). (make: havells /approved vendor list of phed.), 100 amps, 4way, wall mounted copper busbar chamber with steel sheet enclosure (conforms:is/iec:60947-3). (make: havells /approved vendor list of phed.), supply and delivery of the following pipes, valves, pipes and gauges etc at site-- (make: approved vendor list of phed.), 100mm dia m.s. black pipe p/e conforming to is:1239 part-1 (2004), heavy (c class)., 150mm dia m.s. black pipe p/e conforming to is:1239 part-1 (2004), heavy (c class)., 100mm dia m.s. blank flange 15mm thick perforated as per is1538., heavy type suitable dia. ms suspension clamp along with nuts bolts and washers., 100mm dia. cast iron double flanged manually operated rising spindle type sluice valve generally conforming to is: 14846, having body, door, dome / bonnet, gland in graded cast iron to is 210 gr. fg 260, four faces of ss aisi 304 and spindle nut of gunmetal to is 318 gr. ltb 2, outside screw rising stainless steel aisi 304 spindle, valves suitable for a maximum working pressure of 10 kg/cm (seat test) & body tested to 15 kg/cm . flanges faced and drilled to is:1538 table 4 & 6. valves tested by closed end method only. (moc & tc needed for valve)., 100mm dia. cast iron double flanged single door swing non-return valve generally conforming to is:5312 part i, having body, door, cover in graded cast iron to is 210 gr. fg 260; body & door rings of stainless steel to ss aisi 304 , hinge pin of ss aisi 304, valves suitable for a maximum working pressure of 10 kg/cm (seat test) & body tested to 15 kg/cm . flanges drilled to is 1538 table 4 & 6.(moc & tc needed for valve)., 100 mm dia dismantling joint pn-1.0 ci dismantling joint complete galvanised , stud, nut and washer and follower flanges, drilled to is:1538 table 4 & 6. ( at delivery side of pump ), supply & fixing of perforated gi cable tray tee with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. s&f gi connector, 6mm dia ms suspender, bolts & nuts, steel fastener etc. as required of the following size. incl. al painting of ms support. [200x50x1.25mm x 3mtr long (18swg)] [app
Tender For mtps-i es circle em-i sd-iii complete cleaning , tightness checking of horizontal, vertical busbars, bus bar joints, og terminals and checking ir value of ht bus 3a 3b and its bus ducts and annual maintenance works of critical lt modules lt buses
Tender For mtps-i es circle em-i sd-iii complete cleaning , tightness checking of horizontal, vertical busbars, bus bar joints, og terminals and checking ir value of ht bus 3a 3b and its bus ducts and annual maintenance works of critical lt modules lt buses ussg-3a 3b, sssg-3,n e-3, bmcc-3a 3b, vmcc -3a 3b and sbmcc 3 during bunker 3d restoration period
Tender For mtps-i - es circle - em-i?? sd-iii - complete cleaning , tightness checking of horizontal, vertical busbars, bus bar joints, o/g terminals and checking ir value of ht bus 3a & 3b and its bus ducts and annual maintenance works of critical lt modules & lt buses ussg-3a & 3b, sssg-3,n/e-3, bmcc-3a & 3b, vmcc -3a & 3b and sbmcc-3 during bunker -3d restoration period