Get complete information related to latest Cable Glands Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cable Glands Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cable Glands Tenders.
Tender For corrigendum : tender for supply of hea igniter system -hea igniter exciter box , hea igniter cable assembly , hea igniter retractor assembly , hea igniter flexible spark rod assembly , hea igniter spark rod tip , hea igniter guide pipe assembly , local panel , control panel , common manual isolation valve instrument air , air set and air manual isolation valve instrument air with copper tube and fitting from burner front , cooling air one and half inch hard rubber high temperature hose 1500 mm with end clamp , erection materials mounting hardware and other supporting materials cables glandscable lugs
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cableglands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking
Tender For corrigendum : supply of enclosures complying with nema 4x standard , m20 type cableglands fixed in the bottom of the boxes, 60 boxex with 6 cableglands and 60 boxes with 2 cableglands , plane abs or plastic mounting plate fixed in all the boxes , soft copy of serial numbers of the enclosure , charges for transportation of consignment to rmc chennai
Tender For supply of cableglands for ph 1,cable lugs for ph 1,cableglands for ph 2,cable lugs for ph 2,spare cableglands for ph 1 and ph 2,spare cable lugs for ph 1 and ph 2
Tender For a)removal of existing defective solenoid valves, limit switches, junction boxes and connecting cables from its location and identification of cables before removing from the field instruments and junction boxes.b)installation of newly supplied solenoid valves, limit switches and junction boxes in its places.c)termination of cables at field instruments and junction boxes by putting proper cableglands and cross ferruling.d)shifting of supplied materials to kpcl stores and site location will be under the scope of agency/contractor itself.e)handing over of released materials from the field location to kpcl stores will be under the scope of agency/contractor itself.f)finally loop checking of the cables from newly installed junction boxes to plc control cabinets and further checking the operation of field instruments from remote operation through plc/scada system under the supervision of i&c engineer.g)the required consumables/t&p required for the work shall be arranged by the bidder/agency only.