Get complete information related to latest Cable Ties Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cable Ties Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cable Ties Tenders.
Tender For supply of set of 3 types of heavy-duty ultraviolet resistance nylon cableties. 1) nylon cable tie 300 m m x 7.6 mm x 1.78 mm = 30000 nos. 2) nylon cable tie 200 mm x 4.8 mm x 1.25 mm = 49000 nos. 3) nyl on cable tie 160mmx 4.7 mm x 1.25 mm = 20000 nos. as per is: astm-d4066 pa121 and conforming to c lw specn. no. clw/es/c-54. make: newtech/vgs/blackburn/novoflex or equivalent. ]
Tender For supply of cableties size 186 x 4.8mm as per clw spec clw/es/3/0131 alt-e or latest. [ warranty period: 30 months after the date of delivery ]
Tender For supply of 400a incomer fire panel , 300 mm gi perforated cable tray , 150 mm gi perforated cable tray , double compression gland suitable for 300qmm x 3.5 al armoured cable , copper flexible cable size 16sqmm x 4core , copper flexible cable size 25sqmm x 4core , earthing cable single core size 16sqmm x1 core , aluminium lugs size 300 sqmm , aluminium lugs size 185 sqmm , copper lugs size 35 sqmm , copper lugs size 16 sqmm , copper lugs size 10 sqmm , copper lugs size 06 sqmm , copper lugs size 04 sqmm , pg gland suitable for 35 sq.mm x 4core copper cable , pg gland suitable for 16 sq.mm x 4core copper cable , pg gland suitable for 10 sq.mm x 4core copper cable , pg gland suitable for 06 sq.mm x 4core copper cable , pg gland suitable for 04 sq.mm x 4core copper cable , copper chemical earthing , gi earthing strip size 25mmx3mm , cable tie 300 mm , cable tie 200 mm , pvc tape colour , emc 2000a lt panel modification , enclosure crca for extension of panel with cubicle type , 400 a mccb 36 ka with thermal magnetic release , 250 a mccb 36 ka with thermal magnetic release , double compression gland suitable for 400qmm x 3.5 al armoured cable , aluminium lugs size 400 sqmm , straight through jointing kit suitable for 300qmm x 3.5 al armoured cable , ms panel stand for panel mounting , mccb 250a 4 pole with thermal magnetic release with rotary handle and spreader link , mccb panel box with 250a aluminium busbar suitable for 250 a mccb , indication light , ms panel stand suitable for mccb panel box bid number/ & ( * ) : gem/2025/b/6300765 dated/ + : 02-06-2025 bid document/ 2 2 1 / 37
Tender For providing and fitting of emfm to the etp installed and other allied items at jlnm rainawari srinagar - supply, installation, testing and commissioning of electromagnetic flow meter at the outlet and incoming line of effluent treatment plant at jlnm rainawari complying with specifications of annexure b, providing and fitting of submersible extra flexible, waterproof and flame retardant flexible copper wire cable with, class 5-insulation: epr (ethylene propylene rubber)outer sheath: cpe (chlorinated polyethylene rubber) 02 core 1.5mm2 to be laid over cable try of suitable size as directed by site incharge., providing and fitting of ss perforated cable tray of size 50 x 50 mm, the cable tray shall be pre-galvanized of u-shaped. the pvc cableties etc are included., providing and fitting of 40mm dia. ms flange 10mm thickness to the m.s pipe, through electric arc welding of adequate strength & consistency. the job shall include painting of the flanges with two coats of black oxide or enamel paint of approved shade. the job further includes p/fitting of epdm gaskets between flanged joints., providing and fitting of 40mm dia. ms c class pipe and pipe fittings as per requirement at site at inlet and outlet of pipeline, through electric arc welding of adequate strength & consistency. the job shall include painting of the pipe and pipe fittings with two coats of black oxide or enamel paint of approved shade.
Tender For bid to ras supply of xlpe cable for working voltages up to and including 1.1 kv as per is 7098 (part 1) (q2) , mcb - miniature circuit - breakers for a.c. operation as per is / iec 60898 (part 1) (q2) , supply install testing commissioning of step down transformer indoor type voltage rating ht11 bye zero point 433 kv out door type of capacity 200 kva level 2 3 phase 4 wire 50 hz , supply laying and testing 11 kv earthed grades cable xlpe 120 sqmm 3 core , s and f cable end jointing kit for 11 kv grade cable for outdoor termination heat shrink type cable end complete with jointing material and accessories , s and f cable end jointing kit for 11 kv grade cable for outdoor termination heat shrink type cable end , material and labour for pcc 1 ratio 4 ratio 8 type d2 using 40 mm graded stone aggregate for making good cutting portion mass concrete , m and l for pcc 1 ratio 3 ratio 6 type c2 using 40 mm graded stone aggregate for making good cutting portion mass concrete filling of foundations etc including necessary use and waste of form work , supply and fix tpn distribution board 4 way acrylic door 415 volts ac tpn for flush mounting with 100 amps double door copper busbar neutral bar earth bar and mcb incomer of rating upto 100amps , material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directely in ground vertically , supply install testing and commissioning of lt feeder panel of size 1500 x 1500 x 600 mm 3 phase 4 wire 415 v 50 hz ac outdoor type , m and l for brick sub class b 250x115x75 mm and laid in trenches as in protection of ug cable , supply and filling in and spreading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover , returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed , removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1 point 5 mtr above the starting point all as specified and directed , m and l for gl pipe 100 mm light grade laid in trenches floors bye on pole bye road for cable protection with all fittings complete all as specified and directed , boaring holes horizontally under road without damaging the surface of road minimum1pointzero mtr bellow the road surface with the help of gl tubing of any dia not exc 80mm dia for passing of ug cable , supplying and laying reinforce precast concrete cable cover class ht type 1 flat size 300 x180x40 mm for protection under ground ht cable complete all as specified and directed
Tender For corrigendum : for running contract for hon,ble sansad nidhi/vidhayak nidhi and other deposit works under edd-budaun (semi turnkey). - cartage of following material from store center nawada, budaun to je store/je store to site of work including loading & unloading at both ends maximum distance up to 30 km., a) pcc pole 8.5 mrt long/st pole 11 mtr long., b) 11 kv xlpe cable of 3x70/3x120/3x185/3x300 sq.mm., c) 250/400 kva t/f., d) 11 kv ct/pt unit of different size, e) 11 kv jointing kit of different size, f) 11 kv pilfer proof cubical of different size, g) lt abc cable of size 1x16, 3x50, 3x95, 3x120 sq.mm., cartage of line material (11 kv pin insulator, disc insulator, stay set, cross arm, gi wire, earthing rod, ms channel, ms angle, etc) from store centre to dump site & then dump site to site of work on day to day basis, including loading & unloading at both ends maximum distance up to 30 km., cartage of 10 kva & 25 kva transformer from store centre to site of work including loading & unloading at both site, the work of safe carriage 11 kv o/g vcb store center nawada budaun to work of site distance up to 0 to 30 km including safe loading & unloading., cartage of 63 kva to 100 kva transformer from store centre to site of work including loading & unloading at both site., earthing of each 11 kv line pole & t/f properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gi wire., erection of pcc pole 8.5 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., erection of stp pole 11 mrt long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., fabrication and fixing of all 11 kv h.t/l.t. line accessories., erection of double pole on pcc pole 8.5 mtr/stp 11 mtr. long after digging of pit of required size including fabrication and fixing of top channel, droper channel & base channel alongwith, fixing all 11 kv accessories, fuse set 11 kv pin insulators and making connection properly., construction of new plinth for 250/400 kva as per uppcl norms, mounting of 250/400 kva t/f on plinth as per uppcl norms, providing and fixing wiremess fencing for 250/400 kva, erection/installation of following of vcb o/g in consumers site and cable joint of the panel to including earthing, grouting, anchor bolt of panel of making/repairing of pocket for cable to insert in panel form trench and fixing taping of busbar with wiring for ac,dc connection including providing ac and dc supply., chemical earthing for 250/400 kva t/f neutral and body complete, chemical earthing for vcb o/g, mounting of 10 & 25 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of 63 & 100 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of ct/pt unit with proper jumping of ht side and fixing of cable on lt. side of meter cubical properly, fixing of meter cubical as per uppcl norms, making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories., erection of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming., laying lifting stringing of proper sagging of acsr weasel/rabbit/dog conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly., laying lifting stringing of proper sagging of 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm., laying of underground 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm. sizes with open trench by brick & sand as per uppcl norms., filling the 11 kv jointing kit (joint kit providing by c