Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - wt 5023g work of overhauling oil filtration cleaning painting and oil leakage attending work of esp hvr transformers of 200 210 mw unit 3 4 and 5 ukai tps emd 2; overha..
Tender For corrigendum : rep and maint to trnsfrmr, dehydration of trnsfrmr oil, capacitors, painting, ht bushing etc rep to ht over head network and rep/ replacement of ht ug cable, 4 pole/ 2 pole str, god, do fuse and ht poles, cts etc and connected wks at mil stn kannur
Tender For supply of acetylene gas in cylinder,valve spindle replacemant,total valve replacemant,cylinder cap or valve guard,gland nut replacemant,neck ring replacemant,oil trace removable,painting for cylinder,valve fitting,hydro static testing
Tender For corrigendum : supply of m seal , hard wood plank 6x6x1. 5 for fdb sal wood , carborundum , creoste oil for fdb , french chalk , painting brush 4 make hylite , painting brush 3 make hylite , painting brush 2 make hylite , ms rivet 3 , oil filter ssl , air filter ssl , boby filter ssl , pressure pipe for hydraulic
Tender For certain repair to b/r and e/m items in zone c under ge roorkee - demolition of brickwork or stone boulder masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed., m&l for brick work, with class b brick straight or curved on plan to any radius built in cement mortar (1:6) as in raising of manholes and septic tanks complete all as specified and directed, taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed, m&l for rendering 15 mm thick on fair faces of brick surfaces or concrete surfaces and finished surfaces even & smooth in cm 1:4 complete including mixing water proofing compound complete all as specified and directed, supply only water proofing compound complete all as specified and directed., m&l for rendering 15 mm thick on other than fair faces of brick surfaces or concrete surfaces and finished surfaces even & smooth in cm 1:6 complete all as specified and directed, m&l for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed, m&l for preparing newly plastered surface of wall and applying two coats of oil bound distemper complete all as specified and directed, m&l for complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, including filling depressions of scrapped surfaces and applying two coats of oil bound distemper, over and including a coat of 1 mm thick wall care putty with preparation of plastered surfaces complete all as specified and directed., m&l for preparation of old decorated wall surfaces by complete removal of existing treatment on walls including cornices by broming down with steel brush, scrapping down smoke soot, moulds moss and efflorescent salts and trading oil and grease spots and applying two coat of cement base paint inluding one mm thick cement base putty complete all as specified and directed., m&l for preparation of old decorated wall surfaces by complete removal of existing treatment on walls including cornices by broming down with steel brush, scrapping down smoke soot, moulds moss and efflorescent salts and trading oil and grease spots and applying two coats of 100% premium acrylic emulsion paint having voc less than 50 gm/litre and uv resistance as per is 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces inluding one mm thick cement base putty all as specified and as directed. (note: painting of overhead tank min height 18 to 25 meter), m&l in repair for built in steel cup board with pressed steel frame of size 75 mmx45mmx1.25 mm thick with pressed steel shutter 1mm thick godrej pattern fixed to masonry wall by hold fast made out of 25x3 mm flat iron including ms hanging rod of 10 mm dia with bracket fixed on inner side of one leaf of shutter and on other leaf provision of ms peg set of 3 pegs including spray including locking arrangement spray painting with two coats of synthetic enamel paint over one coat of red oxide primer with two coats of synthetic enamel paint over one coat of red oxide primer all around on steel surface of frame & shutter and making good disturbed portion in cm (1:3) or pcc (1:2:4) type b-0 complete all as specified and directed., s&f in repair 110 mm dia pvc (swr) bends any radius with oval access door complete all as specified and directed, s&f in repair 75 mm dia pvc (swr) bends with access door any radius complete all as specified and directed, s&f in repair 75 mm dia pvc (swr) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls including
Tender For overhauling work of 50 mva, 132/33 kv imp make ptr (sl. no. pi-5980) and 50 mva, 132/33 kv ece make ptr (sl. no. s-86706) of 132/33 kv gss, noamundi including oil filtration, painting, oil leakage arresting and including erection and dismantling
Tender For supply of supply of gaskets, o ring, teflon, washer, bushing seal, teflon tape,flex-kwik, devgun putty,supply of materials as per is standard for complete epoxy painting single coat primer double coat paint of each transformer,bucholz relay,mog,breather with silica gel,oil temperature indicator,winding temperature indicator,pressure relief valve,ht bushing,lt bushing,neutral bushing,octc,prismatic gauge,wti ct,aircell,complete marshalling box with all new parts,radiator valves,hv turret ct,lv turret base plate,support insulator,radiator,hardware,site overhauling charges for 12.5mva transformer,oil testing from nabl approved lab
Tender For work of calibration, painting, ultrasonic testing and replacement of s.s. float assembly with its accessories of vertical cylindrical with corrosion proof furnace oil tank of capacity 25 kl at municipal power laundry.