Tender For corrigendum : supply of processor card for diagnostic control dia (dia dds card) (slot u in sb2) for wap-7 & wag-9 (3-phase) loco. as per clw's specification no. clw/es/3/0003, alt.-d abb id. no. hiet404828r0001, type-ppb 624 a01. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of processor card for diagnostic control dia (dia dds card) (slot u in sb2) for wap-7 & wag-9 (3-phase) loco. as per clw's specification no. clw/es/3/0003, alt.-d abb id. no. hiet404828r0001, type-ppb 624 a01. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For lab reagents and xray item purchses - abx cleaner (horbia 3part cbc) , abx lysebio (horbia 3part cbc) , abx minidile (horbia 3part cbc) , abx minoclair (horbia 3part cbc) , probe cleaner (labtech lt360) , lt 360 lyse solution (labtech lt360) , lt 360 diluent (labtech lt360) , urine albumin sugar strip (span aspen) , auto pipette 10 to 100 micro liters , auto pipette 5 to 50 micro liters , auto pipette 5 to 50 micro liters , auto pipette 100 to 1000 micro liters , blood group anti serum abd (j.mitra, meril) , blue tips 100 το 1000micro liter used for pippete , yellow tips 5-50 and 10-100 micro liter used for pippete , clotting capilary tube used for ct test , biochemistry test for used erba kit b.sugar , biochemistry test for used erba kit b.urea , biochemistry test for used serum creatinine , biochemistry test for used serum billirubin (t) and (d) , biochemistry test for used serum s. got , biochemistry test for used serum s. gpt , biochemistry test for used serum serum alk. phosphetase , biochemistry test for used serum serum total protein , biochemistry test for used serum serum albumin , biochemistry test for used serum serum cholesterol , biochemistry test for used serum s. triglyceride , biochemistry test for used serum s. hdl , biochemistry test for used serum s. vldl , cotton roll , cover slip , dengue card combo ns1, igg, igm (sd bioline, meril) , distillede water , erba wash , esr disposable tube with vaccum plug , field stain a and b (diagnostic, organo, aspen) , glass slide 76mm *26mm , gloves 7 and 7.5 , glucometer battery cell , 1glucometer+1000 strip (accu-chek instant, dr morepen bg-3) , hb (hemocque 301) micro cuvette , dengue card combo ns1, igg, igm (sd bioline, meril) , distillede water , jsb stain ist (ases, aspen, dig.) , jsb stain iind (ases, aspen, dig.) , k3 edta vial double cap , lancet , liquid peraffine oil , lugol iodine solution (spam, j.mitra) , malaria card (sd bioline, meril, j. mitra) , needle 22 no. , peri pheral blood semar fixative , print roll for cbc and analyzer , ria tube , sodium citrate 3.8% , sodium hypo cloride solution , spirit 70% , syrings 3ml(dispo/pricon) , syrings 5ml(dispo/pricon) , test tube brush , test tube glass borosil 6 inch , test tube plastik without capplain , tissue paper roll , biochemistry test for used serum serum albumin , biochemistry test for used serum serum cholesterol , biochemistry test for used serum s. triglyceride , biochemistry test for used serum s. hdl , biochemistry test for used serum s. vldl , cotton roll , cover slip , dengue card combo ns1, igg, igm (sd bioline, meril) , distillede water , erba wash , esr disposable tube with vaccum plug , field stain a and b (diagnostic, organo, aspen) , glass slide 76mm *26mm , gloves 7 and 7.5 , glucometer battery cell , 1glucometer+1000 strip (accu-chek instant, dr morepen bg-3) , hb (hemocque 301) micro cuvette , dengue card combo ns1, igg, igm (sd bioline, meril) , distillede water , jsb stain ist (ases, aspen, dig.) , jsb stain iind (ases, aspen, dig.) , k3 edta vial double cap , lancet , liquid peraffine oil , lugol iodine solution (spam, j.mitra) , malaria card (sd bioline, meril, j. mitra) , needle 22 no. , peri pheral blood semar fixative , print roll for cbc and analyzer , ria tube , sodium citrate 3.8% , sodium hypo cloride solution , spirit 70% , syrings 3ml(dispo/pricon) , syrings 5ml(dispo/pricon) , test tube brush , test tube glass borosil 6 inch , test tube plastik without capplain , tissue paper roll , envelopes x-ray (8x10) , envelopes x-ray (10x12) , envelopes x-ray (12x15) , x-ray film (free-8x10 , x-ray film (manul-10x12) , x-ray film (free-12x15) , delopar , fixer , digital film(8x10) , digital film (10x12)
Tender For supply of srphc82278027-crt- p pulse generator for delivery of cardiacresynchronizationtherapy. system should include a current generation crt pulse generator compatible with bipolar steroid-eluting atrial and ventricular leads and a biploar left ventricular lead (coronary sinus ). should provide independently programmable right and left ventricular pulse outputs and interventricular delay ( with the choices of right ventricular alone, leftventricular alone or biventricular pacing as well as the choice of which ventricle is to bepaced first with optimization of delay for pacing of other ventricle ). should have features like negative av hysteresis and triggered modes for continuous delivery of crt. should have advanced features for detection and management and prevention of atrialtachycardias and atrial fibrillation as well as detailed data storage of all arrhythmias and therapy as well as trends over time. should have features for management of atrial fibrillation including mode switch, ventricular rate management etc., pulse generator should be suitable for use with either an endocardial lv lead or an epimyocardial lead for lv stimulation. lv leads should have optimal features for introduction, positioning and fixation and documented low displacement rates. safety and efficacy of the system should be well documented. unit: number. ]
Tender For e-tender for rate contract for supply of lifesaving product (item) used for implantation of lifesaving permanent implant product (item), used for lifesaving cardiac operations and cardiac procedures (adult, paediatric & neonatal) i.e. miscellaneous products (items) for cath lab - (a) sheath introducerset, (b) diagnostic angiography catheter, (c) guiding catheter, (d) guide wire for u n mehta institute of cardiology and research centre (affiliated to b. j. medical college & nabh accredited) ahmedabad, gujarat, india.
Tender For corrigendum : providing of operation and maintenance of other machines and plants - online diagnostic testing of ht motors for two years at nrl site item 10 motor current signature analysis,operation and maintenance of other machines and plants - item 20 vibration measurement of motors,operation and maintenance of other machines and plants - item 30 acoustic emission analysis of motors,operation and maintenance of other machines and plants - item 40 emi testing of motors
Tender For supply of srphc82278027-crt- p pulse generator for delivery of cardiacresynchronizationtherapy. system should include a current generation crt pulse generator compatible with bipolar steroid-eluting atrial and ventricular leads and a biploar left ventricular lead (coronary sinus ). should provide independently programmable right and left ventricular pulse outputs and interventricular delay ( with the choices of right ventricular alone, leftventricular alone or biventricular pacing as well as the choice of which ventricle is to bepaced first with optimization of delay for pacing of other ventricle ). should have features like negative av hysteresis and triggered modes for continuous delivery of crt. should have advanced features for detection and management and prevention of atrialtachycardias and atrial fibrillation as well as detailed data storage of all arrhythmias and therapy as well as trends over time. should have features for management of atrial fibrillation including mode switch, ventricular rate management etc., pulse generator should be suitable for use with either an endocardial lv lead or an epimyocardial lead for lv stimulation. lv leads should have optimal features for introduction, positioning and fixation and documented low displacement rates. safety and efficacy of the system should be well documented. unit: number. ]