Tender For annual rate contract for supply and installation of electrical items and services at padc, panipat - electrical arc padc panipat 1st year, excavation of earth for cable / pipe laying for electrical work excavation of earth for cable trenches / laying of g.i. pipes for cable work in all types of soils including saturated soil upto a max. depth of 1.5 metres including shoring, strutting and bailing out of water (if necessary), backfilling and compacting in layers not exceeding 20 cm. thick to the finished ground level and disposal and dressing of excess earth within a lead of 50 metres all complete with labour and materials as per standards, drawings, specifications and directions of engineer-in-charge., 200 mm x 25 mm x 2 mm, supplying and fixing of gi route marker suppplying cable route marker with 10 cm x 10 cm x 5 mm thick gi plate with inscription thereon, bolted/ welded to 35 mm x 35 mm x 6 mm angle iron, 60cm long and fixing the same in ground as required. job includes painting with one coat of redoxide and finishing paint., 3 / 3.5 / 4 x 25 sqmm, 3 / 3.5 / 4 x 50 sqmm, 1.5 sqmm, 2.5 sqmm, 4 sqmm, 6 sqmm, 10 sqmm, 16 sqmm, 20 sqmm, 25 sqmm, 35 sqmm, 16 sqmm, 25 sqmm, 35 sqmm, 50 sqmm, 10.0 to 16.0 mm, 16 sq. mm, 65 mm dia 3 metre long, 25 x 5 mm gi strip, 64 kg charcoal and 5 kg salt, 100 amps., 63 a tpn 4 way, 5 to 32 amp, 40 amp, double pole, triple pole, triple pole and netural, four pole, 16 amps., 30 ma, 63 amps., 30 ma, 63 amps., 30 ma, 10 a spn. mcb industrial socket outlet supplying and fixing 10 amps., 240volts, spn industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 10 amps. c curve, sp,mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required. note: isi marked sockets shall be used., 20 a spn. mcb industrial socket outlet supplying and fixing 20 amps., 240volts, spn industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps, c curve, sp,mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required. note: isi marked sockets shall be used., 20 a tpn mcb industrial socket outlet supplying and fixing 20 amps., tpn, industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps, c curve, tp mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required. note: isi marked sockets shall be used., 2 + 4 way, provide shock hazard chart supply and installation of shock hazard chart as per ie rules 1956 (clause-44) complete with frame and glass including necessary clamps, bolts, rawl plugs, etc. breachking and making good the wall if required. all complete with labour and materials as per the direction of engineer-in-charge., provide caution board at sub-station supply and installation of "caution boards" mv-200 mm x 150 mm / hv- 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.at sub-stations as per is2551/upto date including supply of necessary clamps, nuts, bolts and other hardware. all complete with labour and materials as per the direction of the engineer-in-charge, upto 5.5kw, plug- 2 pole+ earth, 250v- 20 amp, plug- 3 pole+ earth, 440v- 20 amp, red / yellow / amber / green / milky white leds, blue led, 1 way 5 / 6 amps. piano type switch with isi mark, 1 way 15 / 16 amps. piano type switch with isi mark, 2 pins 5 / 6 amps. penta flush socket outlet, 3 pins 5 / 6 amps. penta flush socket outlet, piano type 5 pins 5 / 6 amps. socket outlet, 3 pins flush type 15 / 16 amps. socket outlet, flush type 6 pins 6 / 16 amps. uni. socket outlet with isi mark,
Tender For re-tender for providing route marker for 11 kv & 33 kv ug cable at different locations of naya raipur under naya raipur sub division under ee (o&m) dn. atal nagar.
Tender For supply of anpr camera ip poe deployed and spare stock , ptz camera ip poe , boom barrier automatic , uhf rfid reader long range high power , uhf rfid windshield tag passive , outdoor led text display , traffic signal light r y g , gi pole 6m , poe managed switch 8 port , poe managed switch 16 port , single mode sfp 1310nm 10km gate end , industrial ups 4 hour backup standard gate load , industrial ups 4 hour backup higher gate load , cat6 outdoor utp cable 305m box , rj45 cat6 connectors boots , outdoor junction box ip65 , manual override pushbutton console , central application server rack tower , network video recorder nvr 32 channel , surveillance hdd 8tb , core managed switch 24 port sfp , single mode sfp 1310nm 10km control room spare , server rack , online ups 4 kva 2 hour backup , patch panel 24 port cat6 , uhf rfid desktop encoder reader , rugged android tablet 10 inch , rugged tablet case screen guard strap , cat6 patch cords 1m 3m mix , lc lc single mode patch cords 3m , fiber termination panel ftp 12 port , fiber optic cable single loose tube 6f , hdpe plb duct 40 33mm , hdpe duct coupler , hdpe duct end cap , route marker warning tape , fiber splicing service fusion , fiber termination panel at gate , otdr power meter testing , civil work , electrical wiring per gate , earthing pit per gate , camera pole installation per gate , boom barrier installation foundation , network equipment installation commissioning , camera configuration anpr calibration , custom software development wages infra , edge anpr sdk , gpu for edge server , edge server , local storage 1tb , wall cabinet 4u ip54 , ups upgrade kit , cabinet fan kit , access controller , led screen 55 inch real time viewing at centre , surge protector ) /bid number : gem/2026/b/7545365 * /dated: 23-05-2026 & & / bid document 1 / 36
Tender For auction sale of depot ferrous scrap - 12112ms26b, 98050011, quantity- 79.435 mts. scrap condemned unserviceable ms-ci signal interlocking materials consisting of levers, rods, ms campus rollers of molb, molb weights, molb booms, signal tubular post, roller trestle, stop boards, 33 mm rods, signal arms, gi and ms wires, lc gate pipes, gate structures, ladders, angles, channels, joists, roller stands, electric poles, cable termination box, direct type lever frame, sa 1914 type trays, sm slides, ssi termination rack, control panels, signal booms, boom locks, cable termination rack, adjustable crank, e type lock, cable marker, ground connection rods, fuse unit, power racks, cam path, gear box, signal reverser, ground lever frame, molb, eolb pedestal, telecom charger body, wire adjustment screws, molb compass roller, gate weights, cls tubular post, surface base, nuts, bolts, rounds, turnout wheels, eye joints, point machine covers, clamps, signal buckets, pulleys, d.w.diversion wheel, gate control panel, calling on unit, gear box assembly with clutch, winch, offset brackets, h.p lock, chequered plates, ptb, location boxes, rkt, axle counter coil fixing plate, shunt signals, route arm, route [1 way, 2 way, 3 way and 4 way], ib hut cut parts, ms electrical point detector, junction type route indicator, route indicators, structures, casing structures, ci bases, gear wheels, flats, cable termination base, u- brackets, ci weights of booms, fabricated posts, cls 2, 3 and 4 aspect units, trestle, sge block instrument, y-crank, stands for wheel tension measuring devices of d.w clutch, lock bar clips, drum clock, ec boxes, relay racks, tlj boxes, foundation shoe, ekt, pd clamps, galaxy stand, meeting posts, signal lamp structures, point rods and other similar signal and interlocking scrap material of sorts and sizes, with or without attachments including negligible nf attachments. note- nf attachments are approximately 2 percent of lot quantity. location- bin no- 112, right side of road no- 1. hsn code- 72044900. gst- 18 percent note: private crane permitted for loading purpose. note- delivery on actual weighment basis only. special note: overload of the carrying capacity of the vehicle will not be permitted at the time of taking delivery as per motor vehicle act 1988.