Get complete information related to latest Chemistry Analyzer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Chemistry Analyzer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Chemistry Analyzer Tenders.
Tender For supply of semi automatic bio chemistryanalyzer as per detailed specifications attached. [ warranty period: 36 months after the date of delivery ] ]
Tender For corrigendum : re-tender for supply and installation of semi- automated bio chemistryanalyzer under nfds & nuhm programme for the year 2024-25 under 15th finance budget
Tender For rate contract for medicine - stainless steel abdominal hysterectomy set, n.s.v set (s.s), g.v set, self abdominal detractor, m.t.p set., vaccine carrier (small size), x-ray digitalisation with high-end cr system (with installation & 1 yers. warrenty) console software with mulitmodality work station the cr system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol., digital ultrasound machine colour dopler (high resolution ) with 4 probe, semi auto analyzer, fully automated bio-chemistryanalyzertechnical specificationsthroughput-150t/hr (constant with both mono and double reagent)system function-random access/stat/batchtest method-end point, fix time, kinetic, (single/double reagents chemistry, mono/ bio-chromatic measurements)calculation methods-1 point linear, 2 point linear, exponential, logit log3p, logit log 4 p, logit log 5p, spline, line graph, k factorblank-reagent blank, sample blank, pre sample blank, pre reagent blanksample tray-40 position, sample volume :2-30 ui, 0.1 ul increment, micro cup, & test tube can be used for samplereagent tray-80 position, reagent volume: 20-300 ul, 1 ul incrementmixing system-teflon coated mixersample probe-1 needle with liquid detector, shock sensoroptics-halogen-tungsten lamp, absorbance range: 0-4.0 abs resolution: 0.0001 abs.diffraction photometry with wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 more optionswash station-12 step washing, 4 needle wash station, 1 dry pad, external needle cleaningcalibration-linear and non-linearqc-multi-level qc setup with levy-jennings graph and westgrads multi rules with mean sd, and cvwater consumption-not more than 6l/hrtemperature-reagent: 2-14 c (24 hr refrigeration), reaction cuvette: 37c 0.1 humidity- 80%system interface-usbpower requirement-ac 220v 10%, 50/60 hzdimensions-750 mm*560mm*530mm, hotair oven, binocular microscope (olampus), centri fuge machin (good quality), micropipette (0-50 microliter), micropipette (0-500 microliter), micropipette (0-1000 microliter), microtips (0-50 microliter), microtips (0-1000 microliter), bed side screen with cloth 1"round pipe with wheel, sponge holding (all size), artery forceps 6" curved, artery forceps 6" straight., artery forceps 8" curved, artery forceps 8" straight., artery forceps 4" straight., alliys tissue forcep (all size curved straight), mosquito forcep (all size curved straight), scissor 6 " curved (all size), scissor 6 " straight (all size), scissor mosquito straight. (all size curved, straight), diatheromy (machine), laparoscopic instrument full set (best quality), needle holder 8 "curved, needle holder 8 " straight, needle holder 6 "curved, needle holder 6 " straight, needle holder 4 "curved, needle holder 4 " straight, doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside, elisa reader with washer mechine with printer & ups., doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside ( best quality), fully automated chemiluminescence analyzer(clia) 1. system should be fully automated walk -away with continuous loading facility.2. analyzer should have able to perform thyroid, bone, cardiac, fertility, diabetes and anemia profile test.3. working principle of system should be micron super paramagnetic particles platform with alp labeled reagents and amppd substrate.4. must have 3 phase magnetic separation with precisely controlled temperature.5. analyzer should have photon counting detection mode with photomultiplier photo counter with led reference module.6. the analyzer must have vortex non-touch mixing which can reduce carryover., 7. throughput of the system should be more than 180 tests in a hour.8. system should have 15 reagents onboard with onboard 2 -8 nonstop refrigeration facility 9. system should have at least 50 sample positions and continuous loading facility.10. system should have continuous reagent
Tender For supply of procurement of fully automated random access continues loading clinical chemistryanalyzer for pathology department of dr. b.a.m. hospital, byculla as per attached technical specifications (comprehensive warranty for 03 years after successful installation and commissioning of the machine). [ warranty period: 39 months after the date of delivery ] ]
Tender For supply of five part hemogram analyzer or complete blood count machine , dental unit with motorized movements, programmable positions and built-in instrument delivery system , portable x-ray machine with high-resolution imaging at the point of care , clinical chemistryanalyzer to measure the chemical composition of biological fluids
Tender For corrigendum : re-tender for kits and consumables for fully automated chemistryanalyzer for the biochemistry - required items, glucose, urea, creatinine, uric acid, total bilirubin, direct bilirubin, sgpt, sgot, alkaline phosphatase, total protein, albumin, ise module reagent pack, ise diluent for urine, calcium (a), phosphorus, total cholesterol, hdl-cholesterol, triglycerides, direct ldl- cholesterol, microprotein, amylase, lipase, microalbumin, iron, uibc, ck nac, crp, rf, aso, ldh, ada, gamma gt, magnesium, hscrp, multicaliberator, autowash, auto wash acid/alkali, ise cleaning solution, pm kit for di plant (ionex), apolipoprotein a-1, apolipoprotein b, cholinesterase, homocysteine, lipoprotein (a), copper, zinc, ammonia