Get complete information related to latest Chemistry Analyzer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Chemistry Analyzer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Chemistry Analyzer Tenders.
Tender For corrigendum : rate contract for medicine - stainless steel abdominal hysterectomy set, n.s.v set (s.s), g.v set, self abdominal detractor, m.t.p set., vaccine carrier (small size), x-ray digitalisation with high-end cr system (with installation & 1 yers. warrenty) console software with mulitmodality work station the cr system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol., digital ultrasound machine colour dopler (high resolution ) with 4 probe, semi auto analyzer, fully automated bio-chemistryanalyzertechnical specificationsthroughput-150t/hr (constant with both mono and double reagent)system function-random access/stat/batchtest method-end point, fix time, kinetic, (single/double reagents chemistry, mono/ bio-chromatic measurements)calculation methods-1 point linear, 2 point linear, exponential, logit log3p, logit log 4 p, logit log 5p, spline, line graph, k factorblank-reagent blank, sample blank, pre sample blank, pre reagent blanksample tray-40 position, sample volume :2-30 ui, 0.1 ul increment, micro cup, & test tube can be used for samplereagent tray-80 position, reagent volume: 20-300 ul, 1 ul incrementmixing system-teflon coated mixersample probe-1 needle with liquid detector, shock sensoroptics-halogen-tungsten lamp, absorbance range: 0-4.0 abs resolution: 0.0001 abs.diffraction photometry with wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 more optionswash station-12 step washing, 4 needle wash station, 1 dry pad, external needle cleaningcalibration-linear and non-linearqc-multi-level qc setup with levy-jennings graph and westgrads multi rules with mean sd, and cvwater consumption-not more than 6l/hrtemperature-reagent: 2-14 c (24 hr refrigeration), reaction cuvette: 37c 0.1 humidity- 80%system interface-usbpower requirement-ac 220v 10%, 50/60 hzdimensions-750 mm*560mm*530mm, hotair oven, binocular microscope (olampus), centri fuge machin (good quality), micropipette (0-50 microliter), micropipette (0-500 microliter), micropipette (0-1000 microliter), microtips (0-50 microliter), microtips (0-1000 microliter), bed side screen with cloth 1"round pipe with wheel, sponge holding (all size), artery forceps 6" curved, artery forceps 6" straight., artery forceps 8" curved, artery forceps 8" straight., artery forceps 4" straight., alliys tissue forcep (all size curved straight), mosquito forcep (all size curved straight), scissor 6 " curved (all size), scissor 6 " straight (all size), scissor mosquito straight. (all size curved, straight), diatheromy (machine), laparoscopic instrument full set (best quality), needle holder 8 "curved, needle holder 8 " straight, needle holder 6 "curved, needle holder 6 " straight, needle holder 4 "curved, needle holder 4 " straight, doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside, elisa reader with washer mechine with printer & ups., doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside ( best quality), fully automated chemiluminescence analyzer(clia) 1. system should be fully automated walk -away with continuous loading facility.2. analyzer should have able to perform thyroid, bone, cardiac, fertility, diabetes and anemia profile test.3. working principle of system should be micron super paramagnetic particles platform with alp labeled reagents and amppd substrate.4. must have 3 phase magnetic separation with precisely controlled temperature.5. analyzer should have photon counting detection mode with photomultiplier photo counter with led reference module.6. the analyzer must have vortex non-touch mixing which can reduce carryover., 7. throughput of the system should be more than 180 tests in a hour.8. system should have 15 reagents onboard with onboard 2 -8 nonstop refrigeration facility 9. system should have at least 50 sample positions and continuous loading facility.10. system should have cont
Tender For corrigendum : laparoscopic simulator. - high capacity electronics oscillating system (5 kva to 100 kva), vitrectomy unit, flow cytometer, solid state photocoagulator, ent powered drill system, iol, hemo diafiltration machine, nct (non contact tonometer), 4 kw high frequency mobile machine, modular monitor, dialysis chair, video endoscope system, disinfectant generation system, fully automated allergy analyzer., body box (plethysmography system), automated plasma expresser., advance visual field analyzer, non contact biometer swept source oct technology., rapid biological indicator for autoclave., laparoscopic simulator.
Tender For corrigendum : 4 kw high frequency mobile machine- high capacity electronics oscillating system (5 kva to 100 kva), vitrectomy unit, flow cytometer, solid state photocoagulator, ent powered drill system, iol, hemo diafiltration machine, nct (non contact tonometer), 4 kw high frequency mobile machine, modular monitor, dialysis chair, video endoscope system, disinfectant generation system, fully automated allergy analyzer., body box (plethysmography system), automated plasma expresser., advance visual field analyzer, non contact biometer swept source oct technology., rapid biological indicator for autoclave., laparoscopic simulator.
Tender For supply of gait trainer three with unweighing system , gaitrite , body composition analyzer , digital colorimeter , centrifuge , hemoglobinometer set
Tender For corrigendum : requirement of spares of abb make so2 / nox gas analyzer system (make: abb, model: el3020) installed in unit1 to 5 of kstps, rvunl, kota - so2 measuring cell (part no-769143), no measuring cell (part no-769143), so2 detector (part no-769118), no detector (part no-769117), ceramic filter(0.3 micron), actuator ss316 body, pneumatic single acting, actuator, pressure sensor for el 3020, model, sample cooler-single coil, sample cooler-double coil
Tender For corrigendum : supply of spares of abb make so2 and nox gas analyzer system (make- abb, model- el3020) installed in unit-1 to 5 of kstps, rvunl, kota - so2 measuring cell (part no-769143), no measuring cell(part no-769143), so2 detector(part no-769118), no detector(part no-769117), ceramic filter(0.3 micron), actuator ss316 body pneumatic single acting actuator, pressure sensor for el 3020 model, sample cooler-single coil, sample cooler-double coil
Tender For supply of semi automatic bio chemistryanalyzer as per detailed specifications attached. [ warranty period: 36 months after the date of delivery ] ]
Tender For corrigendum : re-tender for supply and installation of semi- automated bio chemistryanalyzer under nfds & nuhm programme for the year 2024-25 under 15th finance budget