Get complete information related to latest Clean Agent System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Clean Agent System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Clean Agent System Tenders.
Tender For supply of deluge valve and fire hydrant valve, spare items of deluge valve, spare items of hydrant valve and water monitor for fy 2025-26 installed in fire fighting system at csctpp, rvunl, chhabra
Tender For supply of deluge valve and fire hydrant valve, spare items of deluge valve, spare items of hydrant valve and water monitor installed in fire fighting system at csctpp, rvunl, chhabra
Tender For nctps ii civil maintenance circle civil maintenance division repair and maintenance works to the deluge valve rooms near the gt transformer yard area and mill bunker area at nctps ii
Tender For corrigendum : requirement of supply & fixing of deluge valve diaphragm and rubber seat on emulsifyre system at 220kv kanpur south substation under etd-ii kanpur
Tender For supply of deluge system equipment for msb unit for nrep - a. deluge water spray systems (mvws system + water curtain system + hvws system)cs deluge valve with dry pilot trim & electric release trim, horizontal inlet & horizontal outlet, without skid, ul/fm approved, complete with dry pilot trim with test, alarm & drain devices, local deluge valve control station (dvlcs) (1 no. per dv), pressure transmitters (02 nos per dv.), 3/3 way sil2 certified intrinsically safe solenoid valve-24v dc (1 no. per dv), pressure gauges (03 nos. per dv), air filetr regulator (afr)(1 no. per dv), air vessel of adequate capacity (1 no. per dv), etc. in compliance with the scheme shown in attached "technical data sheets for fire fighting & safety equipment (tk-1p21a-sa-dat-0001)".the deluge valves shall be supplied with the trim and associated instruments duly assemblied with the deluge valve and with suitable packaging to avoid damage during transportation. the upstream strainer, block valves and by-pass valve including the pipes connecting to these items are not in bidders scope of supply.all items shall be suitable and certified for zone 1,iic,t3 area classification. all electrical and instruments shall be certified for intrinsically safe (ex-ia) and solenoid valve shall be certified to explosion proof (ex-d). all instruments and enclosures (junction boxes/ cabinets/panels/ accessories) in field shall be dust proof and weather proof with ip-67., 200 mm nb, 150 mm nb, 100 mm nb, 80 mm nb, mvw spray nozzle with 1/2" mnpt end connection, moc - stainless steel, ul / fm listed, (with inbuilt strainer): size 15 nb, mvw spray nozzle with 1/2" mnpt end connection, k factor-18, spray angle 120 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-18, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-18, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-22, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-22, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-26, spray angle 120 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-26, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-30, spray angle 120 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-30, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-30, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-35, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-35, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-41, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-51, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-51, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-79, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., quartzoid bulb detect
Tender For supply of deluge valve c c - vlv deluge wet pilot trim 50nb , vlv deluge dry pilot trim 80nb , vlv deluge wet pilot trim 80nb , vlv deluge dry pilot trim 100nb , vlv deluge wet pilot trim 100nb , vlv deluge dry pilot trim 150nb , vlv deluge wet pilot trim 150nb