Get complete information related to latest Co2 Cartridge Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Co2 Cartridge Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Co2 Cartridge Scrap Tenders.
Tender For supply of refilling of n2 gas cylinder with capacity 50 l, 200 bar+/-10% in pantry & power cars as per attached specification & scope of work. note- refilling to be done from petroleum & explosive safety organization (peso) accredited refiller. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of carbon dioxide co2 gas for cylinder , nitrous oxide n2o gas for cylinder , oxygen o2 gas for cylinder , nitrogen n2 gas for cylinder , liquid nitrogen
Tender For supply of dgeme cash grant items e e - wc 1.8ltr peso certified n2 gas cylinder , cylinder outlet valve no20 connection , 6mm pu pipe , n2 gas cylinder pressure control regulator , fine pressure selection cum pressure safety device
Tender For supply of uhv deposition chamber - uhv chamber specification (vacuum better than 2 10-9 mbar uhv) chamber overview spherical (diameter 14 ) or equivalent square shaped uhv chamber with support frame equipped with three (3) x 2-inch magnetron sputtering sources. all cf flanges and uhv viewports/ss blanks, three (3) x 2-inch magnetron sputtering sources. each sputtering source has an individual gas inlet line for process gases. all cf flanges., substrate holder : diameter: 2 inches; heating molybdenum heater capable of heating substrate (a) from room temperature (rt) to 800 c during rotation and (b) from room temperature to 1000 c without rotation. rotation: substrate holder can rotate continuously, driven by a stepper motor. variable speed from 0 to 10 rpmmovement: up / down vertical movement of total 25mm to adjust substrate position during deposition sputtering geometry: one sputtering source mounted parallel to the substrate surface, tilt adjustable. two sputtering sources mounted confocally at an angle relative to the substrate. base pressure: lower than 2 10 mbar (ultra-high vacuum)., vacuum pumping system: turbo molecular pump: pfeiffer hipace300 / edwards next 300 / leybold turbovac 350i with cf100 flange or equivalent with integrated controller, ion pump with controller: included to maintain uhv vacuum levels and provide clean pumping., backing pump: pfeiffer hiscroll 12 / edwards nxds 15i / leybold scroll vac 15 plus or equivalent dry scroll pump used to back tmp, gate valves : one cf100 and one cf150 manual gate valves for isolating the chamber from the pumping systems as well as throttling, vacuum gauges and measurement: one cold cathode gauge with readout capable of measuring vacuum pressures down to1 10-10 mbar for precise uhv monitoring., one capacitance manometer gauge with measurement range from 1 10-1 to 1 10 mbar for accurate pressure reading during deposition phase, gas delivery system: two independent mass flow controllers (mfcs):a. one mfc (0-100 sccm) for argon gas feeding to all three sputtering sources via high vacuum valves.b. one mfc (0-100 sccm) for nitrogen gas feeding directly into the chamber with its own high vacuum valve.gas lines for ar and n2 are physically separated to avoid cross-contamination., chamber access and viewports: 1. two view ports installed on the chamber, each equipped with manual shutters. 2. access ports for gauges, pump, gas inlet and few spares for future upgradation., baking capability: entire chamber designed to bake-out at 150 c to reduce contamination and out gassing during operation, cooling capability : water manifold with flow switch / flow meters, near uhv chamber specification: chamber overview: spherical (diameter 14 ) or equivalent square shaped uhv chamber with stand., three 2-inch magnetron sputtering sources, each with individual gas inlet. all cf flanges and uhv viewports/ss blanks., substrate holder: a. diameter: 2inches; heating : molybdenum heater capable of heating substrate (a) from room temperature (rt) to 800 c during rotation and (b) from room temperature (rt) to 1000 c without rotation b. rotation : substrate holder driven by stepper motor. variable speed from 0 to10 rpmmovement: up / down vertical movement of total 25mm to adjust substrate position during deposition sputtering geometry: one sputtering source mounted parallel to substrate surface (tilt able preferred). two sputtering sources mounted confocally at an angle. base pressure : lower than 5 10 mbar (near uhv)., vacuum pumping system: turbo molecular pump : pfeiffer hipace 700 / edwards next 730 / leybold turbo vac 900 ix or equivalent with cf100 flange and integrated controller, suitable for near uhv vacuum., backing pump: pfeiffer hi scroll 12/edwards nxds15i / leybold scroll vac 15 plus or equivalent dry scroll pump used to back tmp, gate valves: one cf150 manual gate valve to isolate / throttle chamber from pumping system, vacuum gauges and measurement: cold cathode readout capable of dis
Tender For corrigendum : sitc co2 and n2 gas pipeline system along with accessories as per bid - high-pressu seamle ste c g cylind filled , high-pressur seamles stee n2 nitrogen ga cylinde filled , co2 changeove hig pressur automati mechanical , n2 changeove hig pressur automati mechanical , gas distributio panel fo 1 outlets , ss tubin pipeline , p u tubing m od , fittings , support casin includin pv casing capping , testin and commissioning
Tender For supply of co2 gas , ar gas , n2 gas , refililing charges of pure co2 per kg , refilling charges of pure n2 per kg price , refilling charges of pure ar per kg price , per trip cost for minimum 10 cylinder per trip.
Tender For supply of points for first year , calibration of glueing m c 8930 by 3 sensor 3 cal points for first year , calibration of vul kettle 8760 by 3 sensor 3 cal points for first year , calibration of hot swaging m c plant no 6229 by 1 sensor 3 cal points for first year , calibration of salt peter n 5 by 3 sensor 3 cal points for first year , calibration of temp gauge by 1 sensor 3 cal points for first year , calibration of gas nitric 35 by 1 sensor 3 cal points for first year , calibration of air circulation by 3 sensor 3 cal pointsfor first year , calibration of high frequency 41 by 1 sensor 3 cal points for first year , calibration of digital graph recorder 1 16 ch without sensor by simulatrion 3 cal points for first year , calibration of hot swill n2 by 1 sensor 3 cal points for first year , calibration of anodising e6 by 1 sensor 1 cal points for first year , calibration of auto film proce 6768 by 1 sensor 3 cal points for first year , calibration of hot air blower 70 by 3 sensor 3 cal points for first year , calibration of hot water anodizing 20 by 1 sensor 3 cal points for first year , calibration of temp control of hot water 02 by 1 sensor 3 cal points for first year , calibration of digital temp. gauge with rtd sensor by 1 sensor 3 cal points for first year , calibration of tvc trolly by 3 sensor 3 cal points for first year , calibration of industrial freezer by 1 sensor 3 cal points for first year , calibration of industrial freezer 2019-14 by 1 sensor 3 cal points for first year , calibration of thermo lab 3c36 and 2c temp and rh measurement by 1 sensor 3 cal points for first year , calibration of oscilation disc rpm measurment for first year , calibration of grese drop point tester 538 1110 by 1 sensor 3 cal points for first year , calibration of quv by 1 sensor 3 cal points for first year , calibration of hot air dryer d1 and d2 by 1 sensor 3 cal points for first year , calibration of hot water cleaning station by 1 sensor 3 cal points for first year , calibration of temp clock for first year , calibration of ir gun up to 500 dec c for first year , calibration of furnace range upto 500 deg c by 1 sensor 3 cal points for second year , calibration of furnace range upto 500 deg c by 3 sensor 3 cal points for second year , calibration of furnace range upto 1250 deg c by 1 sensor 3 cal points for second year , calibration of furnace range upto 1250 deg c by 3 sensor 3 cal points for second year , calibration of furnace range upto 1250 deg c by 6 sensor 3 cal points for second year , calibration of bath range upto 400 deg c by 1 sensor 3 cal points for second year , calibration of bath range upto 400 deg c by 3 sensor 3 cal points for second year , calibration of bath range upto 400 deg c by 6 sensor 3 cal points for second year , calibration of thermometer range upto 100 deg c 3 cal points for second year , calibration of tank range by 1 sensor 3 cal points for second year , calibration of tank range by 3 sensor 3 cal points for second year , calibration of oven range upto 350 deg c by 1 sensor 3 cal points for second year , calibration of oven range upto 350 deg c by 3 sensor 3 cal points for second year , calibration of oven range upto 350 deg c by 6 sensor 3 cal points for second year , calibration of themohygrometer 3 cal points for second year , calibration of hydraulic press range upto 180 deg c by 1 sensor 3 cal points for second year , calibration of hydraulic press range upto 180 deg c by 3 sensor 3 cal points for second year , calibration of chambers furnace range upto 200 deg c by 1 sensor 3 cal points for second year , calibration of chambers furnace range upto 200 deg c by 3 sensor 3 cal points for second year , calibration of //bid details 2 / 81 chambers furnace range upto 200 deg c by 6 sensor 3 cal points for second year , calibration of auto film proce 6760 by 1 sensor 3 cal points for second year , calibration of extrasion mc 6580 by 1 sensor 3 cal points for second year , calibration of spot vulcanising