Web Analytics Made Easy - StatCounter

Co2 Flooding System Tenders

Get complete information related to latest Co2 Flooding System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Co2 Flooding System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Co2 Flooding System Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45595074 Due date: 08 Jul, 202608 Jul, 2026 6.97 Lacs
Tender For servicing, refilling, pressure testing and painting of co2 flooding system and portable fire extinguishers at gdph

Central Government/Public Sector

CTN :45057612 Due date: 23 Jun, 202623 Jun, 2026 NA
Tender For corrigendum : supply of co2 flooding system at ups room

CTN :45557476 Due date: 19 Jun, 202619 Jun, 2026 NA
Tender For supply of spares for co2 flooding system of det-tronics make as per sor

State Government

CTN :45353428 Due date: 04 Jun, 202604 Jun, 2026 7.38 Lacs
Tender For supply and installation of aerosol based fire fighting equipment at indoor ward, eye ward, blood bank, admin building of sdh, gunupur rayagada vide addition/alterations letter no- 8078 dated. 23.03.2026 of dhso buildings. - supply & installation of 8 gm portable aerosol based automatic fire extinguisher (coverage: 0.008 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 20 gm portable aerosol based automatic fire extinguisher (coverage: 0.2 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 30 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.3 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 60 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.6 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 100 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 1 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 200 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 2 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including al

State Government

CTN :45353431 Due date: 04 Jun, 202604 Jun, 2026 10.38 Lacs
Tender For supply and installation of aerosol based fire fighting equipment at new chc building muniguda rayagada vide addition/alterations letter no- 8078 dated. 23.03.2026 of dhso buildings. - supply & installation of 8 gm portable aerosol based automatic fire extinguisher (coverage: 0.008 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 20 gm portable aerosol based automatic fire extinguisher (coverage: 0.2 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 30 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.3 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 60 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.6 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 100 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 1 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 200 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 2 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofeng

State Government

CTN :45353459 Due date: 04 Jun, 202604 Jun, 2026 10.87 Lacs
Tender For supply and installation of aerosol based fire fighting equipment at opd/ipd building bissamcuttack rayagada vide addition/alterations letter no- 8078 dated 23.03.2026 of dhso buildings. - supply & installation of 8 gm portable aerosol based automatic fire extinguisher (coverage: 0.008 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 20 gm portable aerosol based automatic fire extinguisher (coverage: 0.2 m3), en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction of engineer-in-charge. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 30 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.3 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 60 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 0.6 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 100 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 1 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction ofengineer-in-charge. the triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. replacement warranty on the product shall be 3 years and shell-life of 10 years. make-pyrogen/genefire/stat-x/equivalent, supply & installation of 200 gm portable aerosol based automatic triggering through linear heat detection cable/electrical initiation fire extinguisher (coverage: 2 m3) , en 15276-1:2019 and en 15276-2:2019 ,iso 15779:2011 approved ,capable for extinguishing class a, b, c & e fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg celcius including all accessories as per the direction o

State Government

CTN :45259546 Due date: 04 Jun, 202604 Jun, 2026 4.11 Lacs
Tender For following works shall be carried out quarterly during the contract period for the two identical sets of co2 flooding system at mghe power house. the one set of system for carting to the units-1,2,3&4 and the second set of system for carting to units-5,6,7&8. i)cleaning of heat detector externaly with dry cloth ii)ensure working condition of heat detectors iii)cleaning of smoke detector externaly with dry cloth iv)ensure working condition of smoke detectors v)simulate heat and smoke detector simultaneously and check for cross zone vi)checking for leakage in pilot cylinder vii)checking the weight of co2 pilot cylindersviii)check the condition of co2 pilot hose ix)check the condition of co2 discharge hose x)inspect pressure switch and check for its functioning xi)inspect maual call points and check for its functioning xii)inspect abort switch and check for its functioning xiii)inspection of online weigh monitor and check for its functioning xiv)inspect hooter with strobe and check for its functioning xv)checking for healthiness of the battery xvi)checking the condition for slave nrv xviichecking the condition for master nrv xviii)checking of solenoids. xix)refilling of co2 cylinder and pressure testing 45 kg capacity and 4.5kg capacity (in case release of co2 gas during generator fire incidents) xx)any other work connected with the system not explicitly mentioned shall also be carried out for safe and proper operation of the system. xxi)conducting the demo of operation of the co2 flooding system twice (once in 2 quarter) during the annual maintenance contract period for kpcl staff.

CTN :45293358 Due date: 25 May, 202625 May, 2026 NA
Tender For procurement of valves for co2 flooding system at bpcl mr

Central Government/Public Sector

CTN :44823206 Due date: 21 May, 202621 May, 2026 NA
Tender For bid to ras corrigendum : supply of co2 and dcp type fire extinguisher : : - tg9754129002 co2 fire extinguishing equipment , lumpsum charges for supervision of erection and commissioning of co2 fire extinguishing equipment at 18mw stg, nalco damanjodi site , lump sum charges for freight and insurance up to 02-stores, bhel, hyderabad , not to quote 1 , not to quote 2

CTN :45177740 Due date: 15 May, 202615 May, 2026 NA
Tender For subject :- oem tender for procurement of valves for co2 flooding system for fire & safety dept.at bpcl mumbai refinery.
 Loading, Please wait...

Connect us via What's Up