Get complete information related to latest Co2 Flooding System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Co2 Flooding System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Co2 Flooding System Tenders.
Tender For repair/maint of fire fighting, distribution network, pipe line, pumps, panels, valves and connected allied service at cod technical area under ge (i) kanpur
Tender For corrigendum : repair and comprehensive maintenance of swimming pool plant and equipments fire fighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of fire fighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit fire fighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all fire fighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressable manual call point / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and dire
Tender For repair / replacement of unserviceable swts pipe line, fire fighting system, repair / replacement of control valve and other connected works inside depot area at mil stn bharatpur
Tender For repair replacement of fire fighting pipe line fire hydrants hose reel hose box nozzies and other connected items at explosive and non explosive area of nad ins abhimanyu chukar sqn at naval station karanja
Tender For repair/ maintenance and replacement of fire fighting pipe line fire hydrants hose box nozzles and other connected items at ins tunir and common area at naval station karanja
Tender For following works shall be carried out quarterly during the contract period for the two identical sets of co2floodingsystem at mghe power house. the one set of system for carting to the units-1,2,3&4 and the second set of system for carting to units-5,6,7&8. i)cleaning of heat detector externaly with dry cloth ii)ensure working condition of heat detectors iii)cleaning of smoke detector externaly with dry cloth iv)ensure working condition of smoke detectors v)simulate heat and smoke detector simultaneously and check for cross zone vi)checking for leakage in pilot cylinder vii)checking the weight of co2 pilot cylindersviii)check the condition of co2 pilot hose ix)check the condition of co2 discharge hose x)inspect pressure switch and check for its functioning xi)inspect maual call points and check for its functioning xii)inspect abort switch and check for its functioning xiii)inspection of online weigh monitor and check for its functioning xiv)inspect hooter with strobe and check for its functioning xv)checking for healthiness of the battery xvi)checking the condition for slave nrv xviichecking the condition for master nrv xviii)checking of solenoids. xix)refilling of co2 cylinder and pressure testing 45 kg capacity and 4.5kg capacity (in case release of co2 gas during generator fire incidents) xx)any other work connected with the system not explicitly mentioned shall also be carried out for safe and proper operation of the system. xxi)conducting the demo of operation of the co2floodingsystem twice (once in 2 quarter) during the annual maintenance contract period for kpcl staff.