Get complete information related to latest Collision Protector Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Collision Protector Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Collision Protector Tenders.
Tender For construction of aux foundation for installation of a new 160 mva transformer in place of the burnt and failed transformer at 220/132 kv s/s mopka.
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp
Tender For provision of additional transformer alongwith associated items at af stn pune under ge (af)lohegaon - s & f steel tubular swaged poles complete with cast iron plate, finial taper plug, bolt, nuts & screws as specified type 410 sp-55 (11 mtr long) including one coat of red oxide primer and two coats of aluminium paint and making 30 cm wide strips (total -05 nos) with yellow and black paint alternately on external surface above column/pcc benching including numbering with black paint and painting with bitumenous paint internally and externally for portion embedded complete all as specified and directed., s & f air break gang operated switch with 12 nos insulators outdoor type, triple pole, mechanically operated, suitable for vertical installation, single break, provided with locking arrangement consisting of ms chanel ht post type insulator copper alloy, high pressure assembly drop out fuses operating rod of 20 mm dia gi pipe (medium grade) for operating from 1.2 m above gl complete including drop out fuses conforming to is-9921 part-i to v (1982 to 1985) of 1972 rated voltage 11 kv and for current rating 200 amp all as specified, material and labour for lightning arresters nominal discharge current peak 65 ka rating, suitable for operation on ht 11000 volts system, comprising of zinc oxide disks, electrodes, fibre re-in forced composite structure, non tracking weather resistant shedded heat shrinked polymeric housing for withstanding from the effects of pollution, rain, heat and with moisture seal , stainless steel bolts and nuts, stainless steel end fitting cups and fixing arrangements complete all as specified and as directed., m&l for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections i.e m.s. channel or angle sections etc. including new nuts, bolts, washers as reqd dia/length in size, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive one primer coat of red oxide, one under coat and one finishing coat of aluminium paint (1st quality ) as reqd complete as specified., m & l for cement concrete 1:3:6 type c1 (using 20 mm graded aggregate) as lean concrete for coping of pole, stay foundation etc including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified, material and labour for cement concrete 1:2:4, type b-2 (using 40 mm graded stone aggregate) as lean concrete for road finishing even and fair without using extra cement complete all as specified and as directed., supply, laying & testing cable xlpe insulated, screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm., s&f of cable end jointing kit 95 sqmm, 3 core xlpe 11kv ht cable cold shrinkable outdoor type, incl carrying out 5kv megger test after jointing complete all as specified and directed by engr-in-charge., s&f of cable end jointing kit 95 sqmm, 3 core xlpe 11kv ht cable cold shrinkable indoor type, incl carrying out 5kv megger test after jointing ,complete all as specified and directed by engr-in-charge., supply, laying & testing cable xlpe insulated, screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade, of size 3.5 core 400 sq mm including aluminium lugs, cable glands ,complete all as specified and directed by engr-in-charge., supply, laying & testing industral pvc frls insulated single core flexible cable, electric power cables (heavy duty) with stranded copper conductor, 1100 volts grade, of size single core 185 sq mm, including copper cable lugs, cable glands ,complete all as specified and directed by engr-in-charge., supply and install, testing and commisioning of outdoor transformer as per is : 1180 part-i, level-ii step down, copper wound 11
Tender For supply of materials and erection for shifting of control room pannel at 33/ 11 kv sub station bharsawa distt. kaushambi under deposit scheme on turnkey basis under edc, kaushambi - name of work: supply, carriage & erection of materials for control room pannel shifting of shiffting of 33/11 kv s/s bharsawa distt. kaushambi, supply of centralised materials, 11 kv switch gear 600/300/5a 350 mva i/c, 11 kv switch gear 200/100/5a 350 mva o/g, 11 kv 3x300 mm2 xlpecable, 11 kv 3x120 mm2 xlpecable, 24 volt battery, 24 volt battery charger, pcc. 8.5 mtr. long for feeder, 11 kv tpmo switch with fixing clamp, 11 kv top channel, 11 kv dropper angle, earthing complete, stay set complete, 11 kv polymer pin insulator, 11 kv polymer disc insulator, 11 kv disc fiting, 33 kv control panel t/f, acsr weasel conductor, supply of de-centralised materials, 11 kv 3x120 mm2 xlpe cable jointing kit o/d & i/d, control cable 4x2.5 mm2, control cable 2x2.5 mm2, g.i. pipe 6 " dia, rubber matting, clamp with nut & bosts, earth wire clamp for pcc pole, stay clamp for pcc pole, top channel clamp pcc pole, dropper channel clamp pcc pole, g.i. strip 35x6 mm, carriage of following material, pcc pole 8.5 mtr. long., structure of la, 33kv isolator, 33 kv cts, single t/f control pannel, 33kv vcb,11 kv outgoing. incoming pannel, battery & battery charger and other associated accessiories etc. (availibility at concern store center of store division), erection work, installation of 33 kv single transformer control pannel 2 no., incoming 2 no. and 7 no. outgoing in the switchgear room and grouting the pannel by rag bolt using cement, sand mortar in ratio 1:3. work includs fitting of all accessories in all respect with complete connection of control cable with pannel. all material will be provided by the contractor except vcb and crp., construction of cable trenchs with top cover and laying of control cable for vcb, c.t. & t/f control pannel etc. as per direction of engineer. trenchs to be 12 wide and 9 deep. work includes digging, of trench, concreting of the foundation in the ratio 1:3:6 r.b. wall 9 wide with cement mortar 1:4 and plastering inside the trench in the ratio 1:3 and sand filling in the trench. all material will be provided by the contractor., earthing of 11 kv indoor equipments, switchgears as per resspo drawing. with g.i. strip of size 35x6 mm. g.i. strip fully welded at both ends and to be connected with earthmat,, erection of dp with pcc pole 8.5 mtr long with all accessaries and grouting of the pcc pole with cement, sand and brick ballast ratio 1:4:8 size 0.45x 0.45x 1.5 mtr deep under the ground as per drawing no. res-6.(cement, sand, brick, ballast shall be provided by the contractor.), installation of 24 volt battery and battery charger with cabinet in the switch gear room, by grouting base channel 100 x 50 x 6 x 1000mm. fixing of rag bolt., laying of 11 kv 3x300/3x185/ 3x120 sqmm. xlpe cable by digging 0.75 mtr. deep trench, putting layer of sand in the bottom, ramming it, laying of cable over it rmt and covering the cable from sides and top by laying bricks, finally covering the same by earth and levelling of the same, all the materials, except cable, will be pvovided by the contractor., fixing and termination of outdoor/ indoor heat shrinkable cable boxes of size 3 x300/3x185/3x120 sqmm. xlpe cable. boxes will be supplied by the contractor, sundries ( as per site requirement/emergency work), safe dismantling of 11 kv o/g pannel & received back to store, laying of weasel conductor with the help of aluminium roller by hanging three nos. on each support in a manner taking sufficient care to ensure safety of weasel conductor against rubbing on ground, precaution for safety of crops is also to be taken. the work includes jointing of conductor by providing jointing sleaves, stringing of conductor upto correct sag and binding of conductor with insulators on each support. all material shall be provided by contractor such as join
Tender For corrigendum : procurement of equipment for guru vashisth temple and craft foundation - machine, bridge type stone cnc engraving double head machine, bridge type stone cnc profile double head machine, 4 axis rotary cnc cutting & engraving machine, heavy duty block cutter 2.3 mt., heavy duty block cutter 1.6 mt, 5- axis cnc wire saw cutting ht. 8 ft., slurry cleaning plant, eot crane capacity 10 tons, span 55 ft., gantry crane- v type cap.35 tons span 40 ft. l- 100 ft., transformer, electric panel, earthing, cable, other accessory & fitting
Tender For the work of erection, testing and commissioning of dedicated 400kv metering current transformer and inductive voltage transformer and 220kv metering current transformer and inductive voltage transformer, interface energy meters alongwith allied material supply and civil foundation and metering rooms at 400kv gcr chandrapur. (excluding supply of 400kv and 220kv current transformer and voltage transformers). emd rs. 552,823.76/- & tender fees: rs.5,000/- (gst extra).
Tender For installing new 200mva, 220/110kv 3 ph trfr station in existing spare bay available at 220kv ss, brahmapuram- civil works-construction of transformer and equipments foundation at 220kv and 110kv bay, pump house for firefighting system
Tender For construction of equipment foundation and erecting equipments in connection with constructing new 110/33kv, 16mva transformer bay at 110 kv substation, erattupetta .