Get complete information related to latest Condensing Unit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Condensing Unit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Condensing Unit Tenders.
Tender For corrigendum : supply of air conditioner e e - gas check-up pressure testing , full gas charging , nitrogen pressure testing , internal leakage repair , water leakage repair , drain pipe replacement , insulation refixing , copper condenser coil split , copper condenser coil window , copper cooling coil split , cooling coil repair , new compressor , replacement compressor old , pcb repair inverter , pcb repair non-inverter , pcb replacement universal with remote , capacitor , contactor , sensor transfomer fuse replacement , fan motor , blower motor , motor bearing chenge noise adustment , swing flap motor blade replacement , new ac installation , ac uninstallation , outdoor indoor reinstallation , copper piping with insulation and wire , foam jet deep ac service , lite ac service , anti-rust spray external cleaning , visiting or inspection charge
Tender For supplying, installation, testing commissioning of 5000 litres/ hour capacity condensingunit (triple effect) including civil work for milk processing plant at duttnagar, district shimla (hp). sh: truss work, railings, aluminium work and finishing works.
Tender For tender for supply of airconditioners and other items at gwalior airport -supply of 1.5 tr inverter type , 5 star rating as per latest bee norms , hiwall , split airconditioner with rotary compressor operating on refrigerant r-32a/r-410a. the body of indoor unit shall be made of abs/hips/gs condensingunit should be of 100% copper coil & having all safety , air filters , evaporator , condenser , cordless remote , electronic operation control & all accessories supplied with the unit by oem etc as per manufacturer standards suitable for operation on 230 volts , 50 hz , single phase , ac supply , complete as required at site. , supply of 2.0 tr inverter type , 5 star rating as per latest bee norms , hi-wall , split airconditioner with rotary compressor operating on refrigerant r-32a/r-410a. the body of indoor unit shall be made of abs/hips/gs condensingunit should be of 100% copper coil & having all safety , air filters , evaporator , condenser , cordless remote , electronic operation control & all accessories supplied with the unit by oem etc as per manufacturer standards suitable for operation on 230 volts , 50 hz , single phase , ac supply , complete as required at site. , installation , testing , commissioning of 2.0/1.5 ton split inverter a/c i/c supply & fixing of iron angle structure stand suitable for outdoor unit , makeup interconnection , top up refrigerent , painting i/c necessary civil works complete as required , providing suitable size pvc pipe for drawing the gas/drain pipe and wire etc through the concrete/brick wall as required. , supply & fixing of extra copper refrigerant piping for suction and delivery line with all accessories suitable for following capacity acs i/c insulation , gas refiling , power & control cabling etc completed as required.of standard gauge for installation of above units as required at site. , supply & fixing of hard pvc drain piping of proper dia for installation of above units as required at site beyond company provided standard length. , supply , installing , testing and commissioning of 5kva voltage stabilizer suitable for 1.5/2.0 tr split ac units on wall including providing connections etc. as required. (model-v guard vgb 500 or equivalent). , sitc of industrial type ro water purifier having capacity minimum 50 lph capacity with uv & membranes , sediment filter , carbon filter , tds control , water level sensor , 3 prefilter (1 carbon candle and 2 micron filter) , auto flush & output water etc as per manufacturers specifications i/c , making inlet and outlet water connections with water cooler complete. suitable for operation on 230 v , single phase , 50 hz ac supply. , supply of water cooler of fully stainless steel body with thermostate cut- off automatic operation having cooling capacity 40 ltr. per hour and storage capacity 80 ltr per hour , working on 220 v , 50 hz , ac supply including automatically controls with temperature , over load protection , water line connection etc. complete as required . , supply of desert air cooler (duct type) with following minimum specifications as given below. fan size - 18 inch & above. fan speed - 1400rpm/ 3 speed. water tank capacity - 110 litres & above - jointless tank. material of cooler body/sump tank - galvanized steel sheet (isi marked to is 277 latest) cooling media - aspen/wood wool. cooling area - 500sqft & above. cooling pads - on 4 sides. , supply of frp wall support ladder of size 12feet meeting specifications as provided in the technical specifications of the agreement of the work(make - arham/ladderman/sumer/y-access) , supply of frp wall support ladder of size 20feet meeting specifications as provided in the technical specifications of the agreement of the work(make - arham/ladderman/sumer/y-access) , supply of frp tiltable telescopic tower ladder of size 32feet meeting specifications as provided in the technical specifications of the agreement of the work. (make - arham/ladd
Tender For supplying, installation, testing commissioning of 5000 litres/hour capacity condensingunit (triple effect) including civil work for milk processing plant at duttnagar, district shimla (h.p.) sh: truss work, railings, aluminium work and finishing works.
Tender For corrigendum : supplying, installation, testing, commissioning of 5000 litre/hour capacity condensingunit (triple effect) including civil work for milk processing plant at duttnagar, district shimla (h.p.) sh: truss work, railings, aluminium work and finishing works. (recall)
Tender For supply of carry out b check servicing of 320 kva dg set as per specifications , replacement fauly battery and sf of 12v 130 ah battery with 2 year waranty , sf 24v smps battery charger 10 16a , repairing of pumps as required , repair 3 hp borewell pump incl pull out and lowering , attending fault with monor repair and service for 7 or 7.5 tr pakckage ac , repair of split ac incl gas charging except compressor , rewinding of condenser motor for package ac unit 3 phase , supply and charging r22 gas incl notrogen pressure test for package ac units , repalcment of time relay circuit for package ac units , replacement of control card in existing afd system with testing as reqd , replacement of zone card in existing afd system with testing as reqd , replacement of power card in existing afd system with testing as reqd , sf 12v 26ahm battery for existing afd system with testing as required. , laying pvc or xlpe cable in ground upto 35 sq mm as required , laying pvc or xlpe cable on wall or surface upto 35 sq mm as required , supply and making cable end termination for 2 core 6 sq mm al cond cable , testing of existing co2 type fire extinguihsers , refilling of existing co2 type fire extinguihsers , replacment of faulty compressor of extg split ac units with gas charging