Get complete information related to latest Dcdb Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Dcdb Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Dcdb Tenders.
Tender For repair/replacement of external electric supply distribution network with other connected items at malad, marve and kandivali under ge (n) santacruz, mumbai - supply, install, testing & commissioning pedestal cubical type double door lt bus bar chamber box of suitable size factory made modular construction fabricated out of 3 mm thick crca sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements front & back side opening system including rain shed, busbar chamber should be suitable for accomodating all aluminium bus bar strips (50mm x 10mm x 04 nos) & gi strip for earth fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom part, with fixing arrangement on pcc (1:3:6) type c-2 bed block with studs, bolts, nuts & washers, danger notice board with scull suitable for 415 volts or required size to be fixed on pannel including dismantling of old bus bar panel all as specified and directed by engr-in charge.notes:-(a) aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for phases and neutral - 01 set(b) mccb 4 pole , ics=100%icu- 25 ka, 415 volts, 100 amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 nos.(c) digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable ct of appropriate ratio.-01 no make- imp/automatic electrical(ae)/ l&t / havells/ meco(d) panel indicating lamp neon/led type (red ,yellow & blue) with lamp holders - 03 nos(e) panel instrumental wiring with frls suitable size but not less than 2.5 sqmm copper wire single core - 01 job(f) necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.make of mccb & mcb: larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 400 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:- larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 160 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 16 ka 100 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 250 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb all as specified and directed by engr-in-charge make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supplying, laying,connecting, testing & commissioning lt ug pvc insulated, heavy duty, 1100 v grade electric cable with aluminium conductor of size 16 sqmm x 4 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by engineer-in-charge of following sizes:-note : earthwork excavation, dwc
Tender For supply of 415 v,200 a ac and vent pdb_srr-ub as per nit , 415 v, 400 a ac and vent pdb_ss-112 as per nit , 415 v, 100 a ac sub-pdb_srr-ub as per nit , 415 v, 160 a ac sub- pdb_ss-112 as per nit , 415 v, 63 a vent wall mounted db_srr-ub as per nit , 415 v, 100 a vent wall mounted db_ss-112 as per nit , 415 v, 63 a ac-vent wall mounted db_swas room as per nit , 230 v, 32 a wall mounted db_cctv as per nit , 415 v, 200 a sh pdb as per nit , 110 v, 400 a dcdb-1 as per nit , 110 v, 125 a dcdb-2 as per nit , local dol starters as per nit , commissioning spares as per nit , tools and tackles as per nit , mandatory spares as per nit , 16a_lumpsum price for travel by lt switchboards oem to and from site per visit_ 1set is equals to 1 visit_as per nit , 16b_lumpsum price including lodging, boarding etc for services at site for supervision of e,t and c of swbrds by swbrds oem_1 set is equals to 6 man-days_ as per nit , 17a_lumpsum price for travel by lt swbrd oem _ 1set is equals to 1 visit_as per nit , 17b_lumpsum price for serv at site for mod or addl job on swbrds_ 1 set is equals to 6 mandays_ as per nit , training on lt swgr at vendor or oems works as per nit_1 set is equals to 5 days
Tender For providing of custom bid for services - miscellaneous electrical maintenance/oh of power plant lt systems/battery and battery chargers/dcdb/lighting maintenance & street lighting/ electrical shift maintenance jobs/eot crane & hoist, vfd, fire fighting, hydrogen plant, dm ..
Tender For regular operation and maintenance of street lights (with material) at all industrial areas under riico ranpur kota(for 2 years) - regular operation and maintenance of high mast light in ranpur , kota including supply and replacing the required material and labour etc. complete as per the following terms and conditions:- i at any moment a minimum of 90% of total fixture must be in order. the defective fixture must be repaired within 3 days, falling which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate (accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor ). ii contractor shall arrange at his cost for put on & off the street light fixture at appropriate time regularly as per instructions of engineer-in charge. a register shall be maintained at riico/association office and complaint lodged must be attended by contractor within 24 hours. the person deputed by contractor shall attend the riico/association office daily and comply the instructions and attend complaints regularly. iii contractor will have to employ trained and qualified electricians for the work. iv corporation shall not be responsible for any kind of accident during execution of work. v contractor will be responsible for safety and security of fixtures and all concerned materials. vi contractor will be responsible for arrangement of all t&p required for the work vii cost of all labour and material like lamp / balllast wire etc. will be born by contractor. all material required for the work shall not be below the category-ii of concerned bsr item. contractor has to repair and maintenance of fixture with material in all cases like short circuit, phase to phase of jvvnl line etc. viii no extra payment will be made for fixing/removal of extra/existing fixture in the industrial area. ix contractor will be responsible for timely collection and deposition of electric bills of areas in each month. in case of delay in payment and jvvnl impose surcharge for delay payment the same will be recovered from the running bill fo the contractor. payment of electricity bill will be made by riico. x contractor will be responsible for rebate of timer provided by jvvnl. hence contractor will maintain the on/off system by timer properly. in case no rebate is provided by jvvnl due to failure of timer then rebate will be deducted from contractor payment. xi contractor will be responsible for any theft of electricity through poles and he will make necessary arrangements for this. in case of any theft is found suitable penalty will be imposed on the contractor. xii contractor will maintain cubical panel board and assessories fitted in it. in case of any fault repair/replace of material will be done by the contractor at his own cost. no extra payment will be made on behalf of material. xiii contractor has to keep ready total fixtures. in case of fault of fixture a penalty of rs.100/- per fixture per day will be imposed on the contractor., regular operation and maintenance of street light fixtures hpsv/ hpmv (70w/150w) in ranpur, kota including supply and replacing the required material and labour etc. complete as per the following terms and conditions:- i at any moment a minimum of 90% of total fixture must be in order. the defective fixture must be repaired within 3 days, falling which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate (accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor ). ii contractor shall arrange at his cost for put on & off the street light fixture at appropriate time regularly as per instructions of engineer-in charge. a register sh
Tender For bid to ras supply of xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1) (q2) , supply and fixing on load change over switch ss enclosure complete with capacity 200 amp, 415 volt, 4 pole, 50 hz. , supply and fixing sheet metal enclosure spn db double door having facility to fix mcb spn as incomer and mcbs as outgoing, spn 4 ways, ip-43 , supply and fixing sheet metal enclosure tpn db double door having facility to fix mcb tpn as incommer and mcbs as outgoing tpn 4 ways, ip-43 , supply and fixing bus bar chamber 100 amp, 4 way, 415 volts enclosurre is made from crca sheet of thickness 3.15mm crca sheet cover , supply and fixing of straight through epoxy cable joint kit incl jointing materials making joints of ug electric cable 1100 v grade nominal cross sectional area not exc.50 sqmm, 3.5 by 4 core , supply and fixing straight through epoxy cable joint kit incl jointing materials making joints of ug electric cable 1100 v grade cross sectional area 240 sqmm to 300 sqmm, 3.5 core. , supply and fixing end termination epoxy cable joint kit including jointing materials for making joints of ug electric cable 1100 v grade nominal cross sectional area 240 sqmm to 300 sqmm, 3.5 core , supply and fixing of galvanised iron pipe 100 mm bore dia light grade for protection of ug cable , supply of digging nad layingg in excavation trenches not exc. 1.50 m wide and not exc. 1.50 m in depth, complete all as specified and directed. , returning, filling in including spreading, levelling, watering and well ramming in layers not exc. 250 mm in soft loose soil , supply and fixing of galvanised iron pipe 40 mm bore dia light grade for protection of ug cable , supply, installation, commissioning and testing including providing all necessary electrical connection,lt feeder panel board of size 1.0 m x 0.6 m x ) /bid number : gem/2026/b/7568567 * /dated: 22-05-2026 & & / bid document 1 / 30 & & ' ' /item category 0.5 m , supply, installation, commissioning and testing including providing all necessary electrical connections lt feeder panel board of size 0.6 m x 0.6 m x 0.5 m , supply and fixing earhing complete with gi earth plate electrode of size 600x600x6mm thick.complete all as specified and directed in boq spec file , supply and fixing earhing complete with gi earth plate electrode of size 600x600x6mm thick. complete all as specified and directed in boq spec file , supply and fixing of sub-class b brick, well burnt, laid breadth-wise along the axis of cable laid in trenches over sand cushion laid for ug cable protection, complete all as specified and directed. , supply and fixing horizontal boring under a depth of 0.65 m from the gl for passing pipe upto 40 mm bore dia , supply of digging and laying of removing excavated materials soils not exc. 50 m and depositing where directed at a level not exc.1.50 m , taking down out unserviceable or serviceable lt ug cables of nominal cross-sectional area 300 sqmm including bricks, gi pipes etc. , taking down out unserviceable or serviceable lt ug cables of nominal cross-sectional area 50 sqmm 3.5 core including bricks, gi pipes etc. , supply of digging and laying of sand cushioning dry in trenches for protection of ug cables below, above and around the ug cable laid in trenches of 230 mm spread thickness , cutting road by hard standing and making good disturbed surfaces by using pcc type-c2,1-3-6 by using 40 mm graded stone aggregate , boring of holes under road,pavement,hard standing by trenchless technology using ultra sounding technique including hdpe pipe 150 mm dia suitable for 0.4 mpa working pressure , cutting chases, chipping in making good to facings, where required and pointing in cement mortar 1- 3 to ends or edges of landings, steps, sills, sunshades, shelves, lintels etc. , submain wiring comprising single core 2 runs of 6 sqmm nominal coss sectional area frlh
Tender For corrigendum : procurement of 26 nos 220v, 100ah (10 a fc/ 20 a fcbc) battery chargers with separate dcdb and 7 nos. 220v, 100 ah battery chargers without dcdb, 16 nos. 220v, 200ah ( 25 a fc/ 50 a fcbc) battery chargers with separate dcdb and 2 nos. 220v, 400ah (60 a fc/ 100 a fcbc) battery chargers