Get complete information related to latest Delta Starter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Delta Starter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Delta Starter Tenders.
Tender For corrigendum : design, engineering, manufacture, assembly, testing before dispatch, supply and delivery in well packed condition of 11 kv,800a, sc level 40ka for 1 sec load break switch panel ,scope also includes dismantling and removal of existing (old) 02nos.lbs panels of ngef make, disconnection of power cables and control cables and erection of new panels, power cable & control cable connection, bus bar connection, panel connection, testing, and commissioning, lbs shall conforms to iec62271- 102:2003 . detailed scope and gad,bom is as per attached annexures-i to iii
Tender For corrigendum : tender for supply of pneumatic (air) starter , thermo element exhaust temp a bank after turbo , thermo element lo temp measuring , electrical heating element engine pre heating , 3p contactor 9a , 380v a/c 50hz , thermo transmitter exhaust b bank after turbo , pressure element cwp measuring , termo element cooling water temperature(323.805/001/004) , pressure meter 0-40 bar , pressure transducer , starting air , pinion and drive shaft , alternator pre-heating element , voltage control relay , thermo element exhaust temp b bank after turbo , pressure element lub oil pressure measuring , speed tachometer , f/i converter with level relay out put , pressure switch low pressure warning , buffer metalastik , pressure switch low lub oil pressure warning , pressure switch low start air press warning , pressure meter , alarm annunciator , tacho voltage detector u7 , pressure meter , pressure meter , engine control unit , cylinder head gasket (seal ring) , temperature meter , 2p aux relay 5a , 24vdc , 2p circuit breaker 10a , temperature meter , pressure switch , level switch lcwt warning , level switch cool water leak warning , termister control relay , temp switch high lub oil tem warning , temp switch engine pre heating on/off , temperature meter , temp switch hcwt shut down , temp switch hcwt warning , resister 3k3 1w (214-1210) , resister 120k 1w
Tender For supply erection testing and commissioning of equipments at 132/33kv grid station canal - supply of main equipments at 132/33kv grid station canal, auxillary transformer 33/0.433kv, 250kva 3-phase distribution transformer with bimetallic terminal connectors energy level-2, copper wound, battery bank 110 v,300ah of 55 no cells of 2 volt each,sealed maintt. free vrla type, high impact polyprophelene co-polymer container, flame retardant, 110v battery charger (3-phase) (i) float charging and load current ratings 30a/60a/70a/100a at 220v to 252v dc (ii) boost charging current rating : 50a/55a/60a/70a/80a/100a at 198v to 296/302v dc, 33kv vcb indoor type, 1600a with offered operating mechanism. complete in all respects fitted with indoor ct of ratio 1200-600-300/1-1a with 1 spare vacuum interruptor and one indoor type ct set . the vcb shall be compatabile for installation with bus bars of existing indoor type (1+2)bank, 33kv control and relay auxilliary panel completely wired including sub-station automation supporting ieds/numerical relays of make abb/siemens/ge micom/alstom/schneider with iec 61850 compatibility, 70sq.mm 3 core aluminium cable, 1.1kv grade, unarmoured, pvc insulated stranded conductor frls type, 2-core, 6 sq.mm, 1100v, pvc insulated, pvc sheathed, frls, galvanised steel wire/strip armoured stranded copper conductor control cable complete, iron clad change-over switch 300a ( 3 phase), ms-round bars 40mm dia, gi flat (ms) 50x6mm, earth-pit (treated) 3m, cable termination kits 300 sq. mm outdoor, erection of main equipments and write back of dismantled equipments to the divisional store janipur, auxillary transformer 33/0.433kv, 250kva 3-phase distribution transformer with bimetallic terminal connectors energy level-2, copper wound, battery bank 110 v,300ah of 55 no cells of 2 volt each,sealed maintt. free vrla type, high impact polyprophelene co-polymer container, flame retardant, 110v battery charger (3-phase) (i) float charging and load current ratings 30a/60a/70a/100a at 220v to 252v dc (ii) boost charging current rating : 50a/55a/60a/70a/80a/100a at 198v to 296/302v dc, 33kv vcb indoor type, 1600a with offered operating mechanism. complete in all respects fitted with indoor ct of ratio 1200-600-300/1-1a with 1 spare vacuum interruptor and one indoor type ct set . the vcb shall be compatabile for installation with bus bars of existing indoor type (1+2)bank, 33kv control and relay auxilliary panel completely wired including sub-station automation supporting ieds/numerical relays of make abb/siemens/ge micom/alstom/schneider with iec 61850 compatibility, 70sq.mm 3 core aluminium cable, 1.1kv grade, unarmoured, pvc insulated stranded conductor frls type, 2-core, 6 sq.mm, 1100v, pvc insulated, pvc sheathed, frls, galvanised steel wire/strip armoured stranded copper conductor control cable complete, iron clad change-over switch 300a ( 3 phase), ms-round bars 40mm dia, gi flat (ms) 50x6mm, earth-pit (treated) 3m complete including civil works as per drawing, cable termination kits 300 sq. mm outdoor, civil work construction of foundation for auxilliary transformer complete as per drawing (7cum), tool kit
Tender For annual plan ramapuram gp uzhavoor bp project no s0213 26 purchase of lab equipments general electrical work - 1 part i- electrification- and providing ac units( materials used for the work shall be as per list of materials approved by the district level technical committees and attached as separate document), 90.6.10.1:supply and fixing of following sizes of light gauge pvc conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm, 90.6.10.2:supply and fixing of following sizes of light gauge pvc conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm, 1.17.20:supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel/ pvc conduit as required.2 x 4 sq. mm, 1.17.21:supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel/ pvc conduit as required.3 x 4 sq. mm, 90.6.5.13:supply and drawing the following sizes of multi-core pvc insulated & frls pvc sheathed 650/1100 v grade copper conductor round flexible cables conforming to is 694 part i 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 4.00 sq mm, 1.24.5:supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet, 1.27.1:supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 module (75mmx75mm), od52985/2025-2026:supply & fixing 2module metal box with white/ off-white front plate provided with one 20a dp switch modular type in recess including making good the damages, colour washing etc as required (rohs) including giving connections (modular boxes ,switches and accessaries ,make-legrand myrius/mk blenz/havells oro/hager/l&t), 2.10.1:supplying and fixing 5a to 32 a rating, 240/415 volts, 10 ka, ""c"" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing mcbdb complete with connections, testing and commissioning etc. as required.single pole, od63837/2025-2026:supply conveyance installation testing and commissioning of inverter-type wall mounting split ac unit of the following ratings conforming to relevant is suitable for operating on 230v, 50hz, single phase ac supply filled with r-410a or r32refrigerant gas, high energy efficient, rohs compliant, capable of performing functions like cooling, dehumidifying, air circulating, filtering etc. of following capacity including refrigerant copper piping 3mtr with insulation, microprocessorcontrol with cordless remote control etc. - tr 1 phase 3 star rated inverter type split ac unit ( carrier make)( blue star/ daikin / voltas) ( 1 ton 3 star rated ac ), od53026/2025-2026:supply, installation, testing and commissioning of wall mounting split air conditioner unit of the following ratings conforming to relevant is suitable for operating on 230v, 50hz single phase ac supply, filled with r32/410a ecofriendly refrigerant gas, high energy efficient, rohs complaint, capable of performing functions like cooling, dehumidifying, air circulating, filtering etc of following capacity including refrigerant copper piping 3m with insulation, control cable up to 3-5m, 3 m drain pipe, copper condenser, stand, microprocessor control with cordless remote control etc. pcb should have minimum 5 year warranty and 10 year warranty on compressor(warranty card are to be provided). minimum 2 nos free service per year for the entire guarantee period and it should be ensured that the air conditioner is in perfect working condition during this period. 2 tr 3 star inverter a.c unit,
Tender For supply of 2 hp/1.5kw single phase submersible pump set, overall efficiency-25.2, bee star rating-5 sta r, discharge capacity: 0.5 lps, discharge head: 100m, motor speed: 2900 rpm with control panel isi marke d mcb/main switch, ammeter, voltmeter, water level indicator with 100 mtr. flat cable 4 sq.mm 3 core (with each sm pump) make: jee or ksb or calama or worthington or cg or kirloskar or similar [ warranty perio d: 30 months after the date of delivery ]
Tender For repair and maintenance of various gwss/lwss/lis/t/well / hand pumps under jal shakti sub division puruwala in tehsil paonta sahib district simour (h.p.) (sh:- replacement of 100hp star deltastarter with allied accessories at lis killour and repair and rewinding of 12.50hp submersible pumping machinery set at t/well manpur devra near gsss manpur devra)
Tender For a/r & m/o various lwss thural bharanta in tehsil palampur distt. kangra (hp)(sh :-repair & restoration of 50hp star deltastarter& replacement of pvc copper cable of lwss thural bharanta panjlehar source).
Tender For a/r & m/o various lwss thural bharanta in tehsil palampur distt. kangra (hp)(sh :-repair & restoration of 50hp star deltastarter& replacement of pvc copper cable of lwss thural bharanta panjlehar source).