Get complete information related to latest Delta Starter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Delta Starter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Delta Starter Tenders.
Tender For supply of starter 10 hp fully automatic star-deltastarter provided with protection degree ip 54 ( m/s: siemens , l&t , havells only. [ warranty period: 30 months after the date of delivery ] ]
Tender For 5hp non clog submersible sewage pump set, pumping capacity 72 cubic meter per hour at 8 mtrs head with speed 1450 rpm, complete with water protected seal for continuous operating 415v, 50 hz, supply with 10 mtrs, resin filled control cable and 10mtrs s.s chain with shackle and suitable fully automatic three phase starter control panel( dol/star deltastarter which is suitable for that pump) along with single phase preventer with phase reversal sensing and dry run relay protection (current sensing type), thermistor relay and moisture control relay, analog /digital voltmeter , analog /digital ammeter , power on/trip and indication lamps, on/off switch and auto/manual mode switch (authorized dealership certificate to be enclosed while submitting offer, test certificate and warranty certificate to be submitted along with supply). make: ksb, kirloskar, mbh. karvel or similar [ warranty period: 30 months after the date of delivery] ]
Tender For supply delivery and fixing of motor and accessories at ward-1 selliyampalayam oht in narasingapuram municipality - supply and delivery of kirloskar make 15hp/11kw/2900rpm three phase/415v/50hz/ac/tefc horizontal centrifugal monoblock pump impeller-mechanical seal (head-20mtr,flow rate-2154lpm) size:100x100mm (local quotation) 15hp horizontal centrifugal monoblock pump, labour charges for erection of horizontal shaft, centrifugal pumpset (coupled/monoblock) in bore well/open well including fixing of suction pipe and foot valve upto a maximum depth of 7 metres and delivery pipes to the required length with valves,pressure gauges upto the exterior wall of pump room and erection of panel board consisting of tpic switches starter, voltmeter, ammeter, capacitor single phasing preventor and laying and jointing the cables and twinearthing as per ie rules including providing bed blocks etc., complete and operating the pumps and trial run for 10 days including signing of completion of reports as required by eb authorities., three phase panel board star- delta with two level guard and auto start supply and delivery of star-deltastarter confirming to is 13947, iec60947-1 and as amended thereafter with suitable kw rating for operation in ac/ three phase/50hz (+/- 5%) and 415v (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., ct operated ammeter (65 mm dia) with suppressed scale,voltmeter (65mm dia),voltmeter selector switch,miniature circuit breaker, thermal overload relay, air break contactors suitable for next standard higher kw rating, single phasing preventor, dry running preventor and on/off push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capa citor is to be taken separately). three phase panel board for 15hp, supply,delivery and fixing of the following materials are listed below etc..,as directed by the departmental ofiicers.for service4 core 16sq.mm pvc copper ug cable, for motor3 core 6sq.mm pvc insulated and sheathed flat type copper cable, 150mm di pipe, 100mm gi pipe , 100mm gi flange set, rubber sheet for flange set, ms bolt and nut20mm dia and above x 90mm to120mm length fully threaded bolts andwith nuts 2 nos. , manhole cover 60 x 60cm (heavy duty) with frame, supply, erection, testing and commissioning of cast iron body and bronze internal non-rising spindle sluice valve of sizes at required places to control the flow of water including necessary ms flange of table e , gaskets, bolts & nuts including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the departmental officers. 150mm sluice valve, 100amps 4pole mcb, 100amps porcelain fuse unit (500v), 32mm pipe
Tender For corrigendum : blower and motor from the cooling tower with transporting , pvc fill fins for the cooling tower , propeller shaft for the cooling tower with drive assy , cleaning of the cooling tower , supply and fixing for replacement of bush bearing of blower , gaskets and oil complete in all respects , grade gearbox oil for blower , electric motor with suitably sized copper conductor , star deltastarter
Tender For corrigendum : automatic air break star deltastarter panel of ratings 15 h. p , automatic air break star deltastarter panel of ratings 20.0 h. p , automatic air break star deltastarter panel of ratings 25.0 h. p , automatic air break star deltastarter panel of ratings 27.5 h. p , automatic air break star deltastarter panel of ratings 30.0 h. p , automatic air break star deltastarter panel of ratings 35.0 h. p , automatic air break star deltastarter panel of ratings 45.0 h. p , automatic air break star deltastarter panel of ratings 22.5 h. p , automatic air break star deltastarter panel of ratings 17.5 h. p , automatic air break star deltastarter panel of ratings 40.0 h. p
Tender For bid to ras corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission
Tender For supply of lab equipments for eee dept. - list of items:supply of consumble items (for specification details refer notice inviting tender), single phase transformer (detailed specification enclosed), three phase transformer (detailed specification enclosed), dc distribution panel (detailed specification enclosed), dc servo motor drive kit with servo motor (detailed specification enclosed), dc stepper motor drive kit with stepper motor (detailed specification enclosed), linear variable differential transformer measurement trainer (detailed specification enclosed), performance of ultrasonic and moisture sensors (detailed specification enclosed), dol starter interfacing kit (detailed specification enclosed), star deltastarter interfacing kit (detailed specification enclosed), conveyor arrangement with siren (detailed specification enclosed), plc based counting of moving objectson two conveyors (detailed specification enclosed) - list of items:supply of consumble items (for specification details refer notice inviting tender), single phase transformer (detailed specification enclosed), three phase transformer (detailed specification enclosed), dc distribution panel (detailed specification enclosed), dc servo motor drive kit with servo motor (detailed specification enclosed), dc stepper motor drive kit with stepper motor (detailed specification enclosed), linear variable differential transformer measurement trainer (detailed specification enclosed), performance of ultrasonic and moisture sensors (detailed specification enclosed), dol starter interfacing kit (detailed specification enclosed), star deltastarter interfacing kit (detailed specification enclosed), conveyor arrangement with siren (detailed specification enclosed), plc based counting of moving objectson two conveyors (detailed specification enclosed)
Tender For corrigendum : repair maint of water supply installation including rewinding of motors deltastarter and connected works in various pump houses and water point at rms and rajbari