Tender For supply of instruments as per nit documents-, lcr-series- resonant frequency impedance at resonance -quality factor and band width, , make: de tech, , to study the response curve of a series lcr circuit and determine its (a) resonant frequency, (b) impedance at resonance, (c) quality factor and (d) band width, , to measure the voltage across the inductance (l), capacitance (c) & resistance (r) of a series lcr circuit for different frequencies of the input voltages with the help of an ac millivoltmeter & hence 1) to study the variation of impedence of l & c with frequency of the impressed voltage, 2) to draw the resonance curve of the series lcr circuit & to determine the q factor of the circult., , complete with audio oscillator sine wave 0-10v p-p 10khz with digital frequency counter, digital ac voltmeter, digital ac ammeter or voltmeter, digital frequency counter, different values of l, c & r. complete in all respect with detalled manual., , multimeter, digital. low cost heavy duty reliable for student use, , make: imported, , to measure v, i, ohms, transistor hfe, continuity check, diode check. low cost student model., , digital multimeter, lcr model:451, , peak hold facility, , display: 3-1/2 digital 1999 counts backlit lcd low battery and overload indication confirms to iec1010 standards, , auto power off, , dc voltage: 0-200mv/2v/20v/200v/1000v accuracy: +0.5%, , ac voltage: 0-200mv/2v/20v/200v/750v accuracy: 0.8%, , dc current: 0-2ma/20ma/200ma/20a. accuracy: 0.8%, , ac current: 0-2ma/20ma/200ma/20a. accuracy: 1.0%, , resistance: 0-200/2k/20k/200k/2m/20m/2000m.ohms accuracy: 0.8%, , capacitance: 0.20nf/200nf/2uf/20uf/200uf accuracy: 2.5%, , frequency: 0-2k/20k/200k/2m/10mhz accuracy: 1.0%, , inductance: 0-2m/20m/200m/2/20h accuracy: 2.5%, , temperature: -40c-1000c accuracy: 1.0%, , diode test, transistor test and audible continuity test facility., , apparatus for determining variation of thermo emf of, , thermocouple using temperature difference of two junctions, , make: de tech model: dt-temf, , potentiometer with jokey[10 no wire] power supplies:, , dc supply ic regulated +2/4v dc, 500ma. meters: digital voltmeter dc (dual range) digital ammeter dc (dual range) digital galvanometer, , as null detector components are mounted on the panels are: 2 dial decade resistor box on board., , salient features:, , front panel built with high class insulated printed circuit board sheet with well printed circuits and symbols., , instruction manual., , connections are brought out through 4mm colored sockets., , patch cords 4mm., , the trainer is housed in abs plastic cabinet. size of the trainer set 12"x10" accessories with trainer:, , 10 wire potentiometer electrical kettle constantan thermocouple glass beaker thermometer, , set up to determine the co-efficient of thermal expansion of a metal by optical lever & traveling microscope., , make: de tech, , complete experimental set. 1.pullinger's apparatus, , two 1 meter long concentric pipes fitted on a wooden bracket with metal base. outer pipe is covered with asbestos rope & has arrangement for thermometer holes & also steam inlet & outlet at upper & lower ends. supplied with 1 meter long aluminum & steel rods of 1/4" dia. to be inserted inside inner tube., , study of vi and power curves of solar cells, and find maximum power point and efficiency, , to draw v and i characteristics of solar cell and find maximum power and efficiency., , the apparatus consists of optical bench with uprights (length: 1 mtr), cell mounted, meters are fitted on panel with power supply and lamp house with power supply., , measurement of stefans constant using black body, , radiation., , make: de tech model: dt-sbbr, , measurement of stefans constant using black body radiation., , complete with stefans conatant apparatus, very high sensitive light spot galvanometer with sensitivity control, high quality thermocouple.3 it cu boller, rubber tube, electrical heater w
Tender For dental equipments / instruments - 3 point articulator/plane articulator (mean value articulator), acryliser programmable preheating time & temperature programmable curing time & temperature analog control unit capacity-6-8 flask digital programming, adson tooth forceps 5 , adsons tooth forceps 8 , advance digital microscope with imaging software (with desktop + printer + ups + mouse) optical system- infinity color corrected optical system observation tube: seidentopf digital viewing head, 3.2 million pixels high resolution camera system resolution ratio 2048*1536 pixels, line by line scan eyepiece: high eye point wide field plan eyepiece pl10x/20mm, with 5 degrees diopter control, ipd: 50-75mm objective: plan achromatic objective 4x plan achromatic objective 10x plan achromatic objective 40x spring plan achromatic objective 100x s, oil nosepiece: backward quadruple nosepiece illumination- main supply 100v-240v, 3 watt led lamp or 6v/20w halogen with intensity control (fixed center focusing adjustment: coaxial coarse and fine focusing adjustment, with limited and tension adjustment coarse adjustment range: 25mm fine adjustment precision 0.002mm. condenser: n.a.1.25 condenser (with socket for phase contrast and dark field sliders) stage: coaxial mechanical stage 140x132mm size and 76 50mm travel range. inbuilt microscopic scientific digital camera with imaging software consisting of: high resolution digital camera with 1/2 cmos chip usb 2.0 pc connection real time live image resolution: 3 mega pixels electronic shutter exposure time: 1ms-0.3s working temperature: -20 c ~ 70 c image analysis software: sportily calibration line measurements for distance, length, width, perimeter, angle, three point radius. area by enclosed line controlled by four arrow keys available on the keyboard arrow with zoomed preview the line measurement is not affected on zoomed images. identification of objects in an image, count them, obtain several features measurements. objects identification by user or automatically. user defined classification on basis of size or intensity. manual, auto bright and auto dark methods to identify intensity range defined object to be measured. various calculation & measurements available for selected particle are; dimensions, area, perimeter, ferrite length, min/ max radius, thread length, thread width, fiber length, fiber width. roundness, shape, orientation, elongation, equal circular diameter, equal sphere volume, data export report generating and print out interactive file format., agate spatula, air conditioner, air purifier, airotor cartridge suitable for nsk airotor hand piece, airotor control box with inbuilt micromotor , 3 way syringe & 02 nos. airotor control with trolly, airotor hand piece (chuck), airotor hand piece noiseless ultra push type with ceramaic bearing super torque head, airotor oiling machine, alcohol torch with adjustable flame, alginate mixing spatula, allis forcep 5 , allis forcep 6 , alloy cutter compact alloy cutter with high speed grinding and dependable trouble free operation with vaccum suction safety glass for glare elimination and visual protection 20000 rpm, amalgam carrier, amalgamator, anesthesia machine (boyle apparatus) 1. ms & aluminum combined structure with polyurethane coated finish for long life. 2. forged body regulators for medical oxygen & nitrous oxide for maintenance free operation. 3. two numbers each forged yokes with ss fittings for medical oxygen & nitrous oxide at the sides. 4. colour coded yoke mounted high pressure gauges. 5. two tube rotameter with oxygen ratio controller with unitized rotameter. 6. magill s breathing system one number in addition. 7. bain s breathing system one number in addition 8. safety features : oxygen failure warning device (ofwd) nitrous oxide cut off in the absence of oxygen oxygen ratio controller 9. large diameter castor wheels with individual brakes at front castors 10. one year standard warranty 11. local s
Tender For supply of testing equpment for primer and caps - beesley's balance (textiles), plastic caps, live remote temperature & humidity purpose live remote temperature & humidity, alert system, bitumen drum caps/lids, point of care testing equipments, crease recovery tester, shrinkage measurement template & scale universal, electronic milk analysr with adulteration testing equipment, photometer/colorimeter for water testing, techinical grade sulfur hexafluoride
Tender For wheel diameter gauge model wd-2 (e) with digital display for measurement of wheel diameter in both mounted (in situ) and unmounted wheels of track machines. specifi cation: - (1) measuring range: - 650 to 1250 mm (2) accuracy: +/- 0.2 mm (3) applicability: - b g wheels (4) resolutions: - 0.1 mm/0.01 mm /0.001 mm (selectable) (5) measurement at distance of edge: - 63.5 mm (6) distance between axes of ball base: - 250+/-0.5 mm (7) display: - wireles s display on android 7 segment led/lcd (8) power supply: - inbuilt rechargeable battery (9) operating temperature: -10 degree celsius to 60 degree celsius (10) operating humidity: - 15 -85% (no condensation) (11) storage of data: - wireless data transmission with unlimited d ata storage (12) measurement scheme: - 3 point measurement of curve using linear encoder (13) carrying case: - padded ruggedized pvc carrying (14)case functionability: - measureme nt of wheel diameter is possible for loose wheel set as well as without dismantling wheel set. (15) recording of readings: - optional facility on android/device (16) data transfer: - t hrough wireless. part make: pie/ mitutoyo/ hy tech [ warranty period: 30 months after the date of d elivery ]
Tender For supply of temperature control and measurement system for low temperature ranges , temperature control and measurement system for high temperature ranges
Tender For sensors and measurement lab equipment - purchase of sensors & measurements laboratory, voltage, current and power measurement in single phase ac circuit digital power monitor- 10 asingle phase variac 0-240 v, 5 arheostat as load -500 , 5 avoltmeter 0-300 vammeter 0- 5 awattmeter analog 0-3000 welectrical panel & wiring , measurement of current in 3 phase circuit using single ammeter ammeter selector switch 440 v, 6 a 3 loading 5 a 3 phase variac 5 acurrent transformer 3 nos.ammeter 0-10 aelectrical panel, wiring & switches, measurement of resistance using wheatstone bridge necessary connecters provided to connect four arms range of measurement: 5 - 100k accuracy (min to max.): +0.2tolerance: +5%one digital meter provided to indicate the balance conditionsbuilt-in power supplynecessary patch chordsdecade resistance box, measurement of earth resistance by earth tester suitable connectors for 4 main arms and 2 adjacent armspotentiometer to keep the bridge in balance condition.inbuilt 1 khz oscillatormeasuring range : 25mh - 500mhsensitivity : +2mhbulit in audio amplifier with speakerbuilt-in power supplynecessary patch chords decade inductance box, measurement of inductance using anderson bridge suitable connectors for 4 main arms and 2 adjacent armspotentiometer provided to keep the bridge in balance condition.inbuilt 1 khz oscillatormeasuring range : 25mh - 500mhsensitivity : +2mhbulit in audio amplifier with speakerbuilt-in power supplynecessary patch chords decade inductance box, measurement of capacitance using schering bridge suitable connectors with 4 arms providedprovision to connect the unknown capacitance at one armtwo potentiometers provided to keep the bridge balance condition.inbuilt 1 khz oscillator and audio amplifier with speakermeasuring range: 0.001uf - 2.0ufsensitivity: +0.1uftolerance : +5%decade capacitance box , temperature measurement thermocouple trainer kit sensor type: thermocouplerange: upto 99 degree centigradetemperature source: water bath ( 1 kw)bridge: full bridge configurationsignal conditioning output: (0-5) vdcdisplay: 31/2 digital led display & analog thermometeroperating voltage: +12 vdc. -12 vdc, + 5 vdc, - 5 vdctest points: 2 mm sockets, temperature measurement rtd trainer kit sensor type: rtd (pt100)range: up to 99 degree centigradetemperature source: water bath ( 1 kw)bridge: full bridge configurationsignal conditioning : (0-5) vdcdisplay: 31/2 digital led display & analog thermometeroperating voltage: +12 vdc. -12 vdc, + 5 vdc, - 5 vdctest points: 2 mm sockets , behavior of proximity sensors proximity sensor of inductive provided to detect the metallic object. capacitive sensor provided to detect both metal and non-metal object.switching circuits provided to actuate the buzzer and relay.inbuilt regulated power supply.housed in a powder coated cabinet, linear variable differential transformer measurement trainer type: inductiverange: (0-25) mmexcitation: 4 khz, 1 v pp sine wavecalibrated range: (0-20) mm or + 10 mm/-10 mmsignal conditioner output: 0-5 vdc or +5/-5 vdcdisplay: 31/2 display digit ledmicrometer range: (0-25) mmtest points: 2 mm sockets, performance of ultrasonic and moisture sensors arduino uno board ultrasonic sensor to measure the distance.moisture sensor to measure the humiditylcd displayselector switch for display of sensor output.regulated power supplymount in a closed cabinet