Web Analytics Made Easy - StatCounter

Drift Eliminator Tenders

Get complete information related to latest Drift Eliminator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Drift Eliminator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Drift Eliminator Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government / Public Sector

CTN :45149143 Due date: 30 May, 202630 May, 2026 NA
Tender For corrigendum : providing of custom bid for services - 9070c26a86 hiring of air cooled chiller unit for temporary cooling during utility shutdowns steam and or cooling water at different control rooms of paradip refinery

State Government

CTN :45309859 Due date: 29 May, 202629 May, 2026 NA
Tender For repair & maintenance work of acb drift eliminator of cooling tower- 7a & 7b with supply of drift eliminator & grid support channel at odp-ii, cstps, chandrapur.

State Government

CTN :45064324 Due date: 02 Jun, 202602 Jun, 2026 3.02 Lacs
Tender For corrigendum : ktps v vi stages- civil- o m-i- repairing to the damaged portions of ring beam and columns of ixth and xth unit cooling tower of ktps v stage, paloncha

CTN :45318506 Due date: 05 Jun, 202605 Jun, 2026 NA
Tender For supply of engine valve door packing kit , valve door bolt set , engine head gasket set , head bolt push set , the above mentioned engine head system oh repair remove , hydraulic pump assembly , hydraulic repair seal kit , hydraulic rod washers and seals , hydraulic pressure holding service kit , the above mentioned hydraulic pump assembly oh repair , front shaft pedal bearing , oil seal set , gasket kit , lock washer and bolt, nut set , the above mentioned front pedal shaft assembly oh repair , bs-iii radiator assembly , inter cooler repair , coolant plastic dat-mtd single cap , radiator hose pipe , the above mentioned engine cooling system oh repair removes , air dryer repair kit , air compressor repair kit , cylinder oil seals , cylinder roaring and packing , rotary pump fuel pipe , the above mentioned engine compressor system oh , the above mentioned engine compressor presser system oh , break master cylinder repair kit , break booster assembly , break booster adjuster yoke assembly , the above mentioned break booster oh repair , the above mentioned break booster oh repair remove , break booster adjuster yoke assembly , hand break valve assembly , the above mentioned break booster repair the all parts , steering rod and column assembly , steering gear box service kit , steering gear box seal kit , lock washer and bolt set , the above mentioned steering overhauling repair removes , lh switch , lock kit , iron wire spokes , cylinder kit , damper rr wheel , skf bearing , brake shoe , gasket r crank case , panel comp break , rear brake drum , unit assy fuel , chain spocket kit , rim rr wheel , side shield , front madgurd , cam chain kit , cam shaft , arm comp, valve rocker , dc kit , ngk cr6hsa plug )

CTN :45182405 Due date: 29 May, 202629 May, 2026 NA
Tender For corrigendum : supply of split air conditioner, wall mount type (v3) isi marked to is 1391 (part 2) (q2) , split air conditioner, floor mount type (v3) isi marked to is 1391 (part 2) (q2) , supply and fix window type air conditioner electric driven single phase cooling capacity 4500 k cal per hour 1.5 ton bee 3 star , material and labour for sub-main wiring surface type with two run of pvc insulated, unsheathed, frls single core and one run of 4.0 sqmm copper conductor , supply and fix single pole and neutral enclosure 240 volt, 20 amps with a two pin and earth plug and socket complete with one single pole mcb , supply and fix automatic voltage stablizer single phase 220 volt 50 hz of capacity 5 kva all as specified and as directed , m and l cutting chases, pinning in making good to facing where required and pointing in cement mortar 1-3 to ends or edges of landings, steps, cils, sunshades sheleves, lintels, etc , material and labour for sub-main wiring surface type with two run of pvc insulated.unsheathed, frls single core and one run of 6.0 sqmm copper conductor , m and l for stand bracket fabricated from structural steel section suitable for 3 ton ac outdoor unit including nut, bolt, washer, welding. bedding cold or hot , supply and fix single pole and neutral enclosure 240 volt, 40 amps with a two pin and earth plug and socket complete with one single pole mcb , supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and 90 v to 300 v with output voltage stabilized at 230 v , supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type and d 170-270 volt with output voltage stabilizer at 230 volt , s and f motor starter 25 amp with on off push type switch, modular type two module make make legrand-gm-havells , s and f socket 25 amp modular type two module make legrand-gm-havells , s and f metal flush box, modular type four module make legrand-gm-havells , s and f cover plate with metal frames, modular type four module make legrand-gm-avells , m and l for stand-bracket fabricated from structural steel section suitable for 1.5 ton- 2 ton ac outdoor unit including nut, bolt, washer, welding. bedding cold or hof, drilling holes for bolts , supply and fix power socket 240 volt ac 25 a 2 module all as specified and directed , supply and fix 25 a motor starter 2 module all as specified and directed , supply and fix modular white cover plate metallic frame 2 module all as specified and directed , supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 90 v to 300 v 230 v //bid details 2 / 25

CTN :45324777 Due date: 08 Jun, 202608 Jun, 2026 18.00 Lacs
Tender For condition assessment of rcc structures of cooling tower unit-1, kalisindh thermal power project, jhalawar.

CTN :45321592 Due date: 08 Jun, 202608 Jun, 2026 18.00 Lacs
Tender For work contract of condition assessment of rcc structures of cooling tower unit-1, kalisindh thermal power project, jhalawar

CTN :45309335 Due date: 13 Jun, 202613 Jun, 2026 14.13 Lacs
Tender For procurement of miscellaneous items for unit 4 overhauling, sgtpp - sgtpp, air filter, complete set, 250 srs filter for paph/saph [500 mw boiler] air motor veljan , port size 1inch bspt (body ported), max pressure10 bar having 40 micron sintered bronze filter element with manual drain, alumin wl & nitrile seals ( (oil side set) ), bowl of air filter for air motor of paph/saph [500 mw boiler] veljan with manual drain suitable for 250 srs filter,moc: poly carbonate. ( (oil side) ), silencer (pn:400450035) for air motor of paph 400450035 iec dusterloh ( for paph & saph air motors ), hose barb/nipple size 3/4" mnpt x 1/2" ( hose nipple 1/2 "x 1/2 "-120 nos and hose nipple 3/4 "x 1/2 "-80 nos. outer thread at one end and one end will be fitted with 1/2" rubber hose moc: ms application area: air boosting line at mrhs [quoted as per additional text description] ), needle valve,ss316 ( size: inch 3000 psi ,moc ss 316, ferrule end connection make:baldota. [quoted as per additional text description] ), flexible hose, id-12.7 mm, l-613 mm, for oil gun 500mw boiler , moc: ss 304, ms split pin # ( ms split pin, size: 4x80 [quoted as per additional text description] ), split pin # ( ms split pin, size: 3x80 [quoted as per additional text description] ), rubber hose size 1/2" ( 1/2 inch flexible rubber hose. moc: high quality braided rubber application area: at dome cooling water line of mrhs. [quoted as per additional text description] ), jubilee clamp; size: 1 ( jubilee clamp: 1/2 inch application area: at hose of air boosting line at mrhs. moc: gi [quoted as per additional text description] ), expansion joint,mrs,mill xrp 1003 for mill xrp 1003 dia- 241 mm., length- 210 mm. ( expansion joint,mrs,mill xrp 1003 for mill xrp 1003 dia- 241 mm., length- 210 mm. with extra flange attached with inner sleeve,pressure rating - 3.5 kg medium - coal reject. minimum temp to be withstood-300 deg c. ), hose, seal air, mill xrp 1003 ss flexible hose, od - 64 mm. length - 900 mm.both side hex nut socket fittings, filter,suction,600x600x50mm,ss net 3layers,5 micron ( application: for ac & dc scanner air fans ), loctite super glue in tubes 013 gms/2gm tube ( loctite sl 5910 each contains: (300 ml) [quoted as per additional text description] ), loctite 270 (thread lock) # ( loctite 241 each contains: (50 ml/51.3 g) [quoted as per additional text description] ), stainless steel net, width:470mm for 500 mw boiler trough seal , wire thickness: 5 mm, square gap:11 mmx11mm, moc: ss 416., lubricating paste altemp q nb 50 for pa & fd fan make- kluiber ( total 5 nos of tubes. each tube contains 80 gm ), strainer for blowdown transfer pump part no-15 wpil pump model: vo wpe 80-400/ 100-320,drawing no. bvk-50150-151/50152-153/50154-155, moc:ms ( application: boiler blowdown pump moc: ms ), shaft set,moc- ss410,vo wpe 100/320 for blowdown transfer pp vo wpe 80/400 & 100/320 pt no-7 wpil for pp sl no. bvk-50150-151/bvk-50152-153/bvk-50154-155 ( 4 sets: slightly larger, 2 sets: slightly smaller dimension as per drawing ), screw,self drill,washer,5.5x25mm ( hex flange head-pvc washer blue zinc coated-coarse thread size: 5.5x14x25 mm make: welfast ), coupling sleeve for blowdown transfer pump wpil part no-21 wpil pump model: vo wpe 80-400/ 100-320,drawing no. bvk-50150-151/50152-153/50154-155,wpil,moc: ss 410 ( shaft sleeve /coupling sleeve-a. as per drawing of boiler blow down pumps spares ), shaft sleeve for blowdown transfer pump wpil part no-19 wpil pump model: vo wpe 80-400/ 100-320,drawing no. bvk-50150-151/50152-153/50154-155, moc: ss 410 ( shaft sleeve-b. as per drawing of boiler blow down pumps spares. ), rubber bearing ( rubber bush/cut less bearing, moc:inner: teflon, outer: brass (copper-85%, tin-85%, lead-85%, zinc-85%). as per drawing of boiler blow down pump#s spares (larger-10+smaller-5) ), bush bearing/ b. housing for blowdown transfer pump wpil part no-20 wpil pump model: vo wpe 80-400/ 100-320,drawing no. bvk-50150-151/50152-153/50154

CTN :45305740 Due date: 02 Jun, 202602 Jun, 2026 NA
Tender For camc of 1000tr chiller plant-camc for 1000 tr (200 tr x 5 nos.) chiller unit, condenser water pumps, chiller water pumps, cooling towers etc. installed in the ac plant room at klc, tvpm for the period of one year from 22/03/2026 to 21/03/2027

CTN :45303437 Due date: 26 May, 202626 May, 2026 43.5 Thousand
Tender For provision of electrical item at the residence office of shri gaurav goyal, joint secretary, new delhi.subwork/packages:provision of electrical item at the residence office of shri gaurav goyal joint secretary, new delhi. - supplying , installation, testing and commissioning of air cooled hi wall split type air conditioners complete with indoor unit(idu), out door unit (odu), surface / concealed copper refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 mtr (idu to odu), copper power cable upto 3.5 mtr (idu to odu) i/c drain pipe r-32/r-410/ r-407 green refrigerant, wireless remote control, suitable for working between 180- 260v with low & high voltage cutoff and 50 hz ,1 phase ac supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll / rotary compressor. the system shall be able to deliver 100% of the rated capacity upto 42 0c. min 5 year original equipment manufacturer (oem) warranty both compressor and printed circuit board (pcb). must comply : electrical cable is 694 or is 9968 temperature sensing control is/international electrotechnical commission (iec) 60730, hermetic compressor is 10617, heat exchanger is 11329, capacitor is 2993 and motor is 12615. complete as per cpwd specification and is : 1391 part ii 2023. the system shall be able to operate up to 50 0c (out door ambient temperature). inverter type - cooling only
 Loading, Please wait...

Connect us via What's Up