Get complete information related to latest Earth Strip Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Earth Strip Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Earth Strip Tenders.
Tender For repair and replacement of unserviceable parts of dg set, corroded panel, repair of earthing strips, unserviceable sign board, lighting conductor, pcc works, stp and rewinding of motors including allied works at bagrakote mil stn under ge sevoke road
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be
Tender For tender for supply of outdoor full hd day and night ptz ip camera , camera mounting bracket heavy duty gi , camera junction box weatherproof , spike buster 4 port , camera pole gi 6 mtr with stair provision , pvc pipe heavy duty , pvc box 3x3 , led light 50w ip66 , solar panel , gi pole for light 6 mtr , pole foundation rcc , outdoor jb for light termination , ofc 6 fiber cable , ofc joint closure , ofc liu 12 port loaded , ofc patch cord lc-sc , network switch 8 port poe with sfp slot , sfp module pair , outdoor utp cable , power cable 2 core x 10 sqmm , nvr 32 channel ip , nvr 16 channel ip , nvr 08 channel ip , hdmi cable 10 mtr , surveillance hdd 10 tb , led tv 75 inch , wireless mouse , network rack 27 u , 24 port network switch sfp modules , installation system testing transportation
Tender For supply of vacuum filter spares & service-spare parts of & work for 10 x 20 vacuum filter ,brass zig-zag 2 long ,s.s binding strip ,s.s. perforated screen ss 304 13 x 10 salem ss 304 (weight 1.72 kg.) ,heavy duty railway hose pipe size: 2 bore x 18 long ,s.s. bolt x ,scrapper belt 5 width 8 ply ,lead wire 3/8 ,s.s. decking plate 1 x 10 (ss 304) ,s.s. capillary pipe with s.s. junction box six way & main connecting pipe junction box to vacuum distribution valve (complete set) ,s.s. divisional strip ,copper rivet size below:- ,size: 4mm x 12 mm ,size: 5mm x 15 mm ,pvc spray nozzle ,m.s. connector (hexagonal) both & thread ,reconditioning work ,repairing charges of dismantling, refitting of damaged capillary, nipple, junction box 6 way along with column pipe upto vacuum distribution valve all work should complete in all respect both portion of 10 x 20 rotary vacuum filter, damaged decking plates replacement & fitting work to be completed, all ss perforated screen dismantling & refitting after cleaning of decking plates & damaged decking plate replacement. hydraulic testing to be done capillary section inside drum as well as drum to made leak proof, insure the trouble free working throughout the season 2026-27 damaged ss perforated screen replacement work in 2 nos. other filters (approx = 20 nos.)
Tender For corrigendum : supply of providing and fixing 50 mm outer dia pipe and 25mm inner as per boq item no.3.6.1 , providing and fixing 8 swg gi earthing wire supply and laying as per boq item no.3.6.2 , providing and fixing 25 mm x 6 mm gi earthing strip supply and laying as per boq item no.3.6.3 , providing and fixing, supply and installation 150 mm wide cable tray as per boq item no.3.7.1 , providing and fixing, supply and installation 300 mm wide cable tray as per boq item no.3.7.2 , providing and fixing, wiring for lightor bell point with 2-1.5 sq.mm and earth wire of 1.5 sq.mm as per boq item no.3.8 , wiring for looped light with 2-1.5 sq.mm and earth wire of 1.5 sq.mm green both are of isi marked approved as per boq item no.3.9 , providing and fixing,wiring for fan or exahust fan or wall fan point with 2-1.5 sq.mm as per boq item no.3.10 , providing and fixing on board 6a, 5 pin socket controlled by 6a switch as per boq item no.3.11 , providing and fixing 6or16a, 5 pin socket controlled by 6a switch as per boq item no.3.12 , providing and fixing 6or16a, 5 pin socket controlled by 6a switch - single phase as per boq item no.3.13 , providing and fixing 6or16a, 5 pin socket controlled by 20a moduler sp mcb as per boq item no.3.14 , providing and fixing 2 x 1.5 sq.mm and 1 x 1.5 sqmm. copper wires with 25 mm dia frls conduit as per boq item no.3.15.1 , providing and fixing 2 x 2.5 sq.mm and 1 x 1.5 sqmm. copper wires with 25 mm dia frls conduit as per boq item no.3.15.2 , providing and fixing 2 x 4 sq.mm and 1 x 2.5 sqmm. copper wires with 25 mm dia frls conduit as per boq item no.3.15.3 , providing and fixing led rope lights as per boq item no.3.16 , providing and fixing 36w led 600mm x600mm fixture as per boq item no.3.17 , providing and fixing 18w led down lighter openor concealed as per boq item no.3.17.1 , providing and fixing 12w led down lighter openor concealed as per boq item no.3.17.2 , providing and fixing 10w led linear spot light as per boq item no.3.17.3 , providing and fixing 6worm strip light as per boq item no.3.17.4 , providing and fixing 2worm strip light as per boq item no.3.17.5 , supply installation testing and commissioning of 1200 mm 50w five star ratting as per boq item no.3.18.1 , supply installation testing and commissioning of 914 mm 60w five star ratting ceiling fan as per boq item no.3.18.2 , providing and fixing 32 mm dia. pvc conduit as per boq item no.3.19.1 , providing and fixing 25 mm dia. pvc conduit as per boq item no.3.19.2 , providing and fixing 100x50 mm pvc raceways white as per boq item no.3.19.3 , providing and fixing 50x50 mm pvc raceways white as per boq item no.3.19.4 , providing and fixing,supply, laying of cat 6 utp computer wire with conduit as per boq item no.3.20.1 , information outlets - providing and fixing,supply, installation testing and commissioning as per boq item no.3.20.2 , providing and fixing,sitc of cat6 24 port patch panel rack mount with lable as per boq item no.3.20.3 , providing and fixing,sitc of cat6 patch cord for patching at user desk 1-mtr. as per boq item no.3.20.4 , providing and fixing,sitc of cat6 patch cord for patching at user desk 2- mtr. as per boq item no.3.20.5 , providing and fixing,sitc of 6u wall mount rack for mounting devices with all required as per boq item no.3.20.6 , providing and fixing 2-module modular switchboard plates as per boq item no.3.20.7 , providing and fixing 4-module modular switchboard plates as per boq item no.3.20.8 , providing and fixing 6-module modular switchboard plates as per boq item no.3.20.9 , providing and fixing 8-module modular switchboard plates as per boq item no.3.20.10 , providing //bid details 3 / 84 and fixing 12-module modular switchboard plates as per boq item no.3.20.11 , providing and fixing,supply, installation testing and commissioning of rj 11 jack type as per boq item no.3.20.12 , providing and fixing,supply and installation of interactive panel as per boq item no.3.21 , providing and fixing,supply an
Tender For repair, replacement, improvement and maintenance of unserviceable earthing, earthing strip, sign board including allied works at various locations of sevoke road mil stn under ge sevoke road
Tender For running maintenance of plc system - running preventive and breakdown maintenance of plc control system with electrical drives all control and instrumentation system of ash handling , replacement new erection of impulse line , replacement new erection of instrument fitting adopter nut tails elbow connector etc , overhauling b 501 and b 601 ss cock valve , overhauling repairing of junction boxes , servicing recalibration erection of fuzi yokogava rosemount etc transmitters , overhauling and recalibration new erection of digital indicators , overhauling and recalibration erection of flow meter conductivity meter , complete overhauling erection of level switches , replacement of pressure switch gauge vibration switch , removal testing erection commissioning calibration of temp gauges switches thermocouple , replacement erection overhauling cleaning of union isolating valveforged body valve , blowing of tapping points of different pressure transmitters switches , fabrication repairing of instruments plateform , laying patrolling of instrumentation cable , servicing and maintenance of air conditioner , cleaning of control room plc system , repairing of ups , service replacement of faulty butterfly valves along with act , servicing replacement of faulty diaphragm type valves , changing spindle gland of root valves , cleaning blowing by air of impulse lines , attend leakage from steam water air line , replace gauges switches of pressure temp , testing caliberation of pressure gauges , testing calibration of pressure switches , testing calibration of temp gauges , testing calibration of temp switches , replacement of thermocouples , cleaning servicing of terminal block in compressor house swas system , changing of ss root valves , servicing of 10mm hp lp 3way manifold valves , replace of 10mm hp lp 3way mfold valves , removal choking replace of impulse line , erection replacement of pvc armored compensate cable , replacement of universal digital indicator , servicing replacement of faulty 4way valve with actuator , replacement remounting of smps 24 v dc , dismantling replacement of combination timerof compressor , servicing of sampling cooler dhx18 sco2 , servicing of sampling cooler dhx12 sco2 , servicing of sampling cooler dhx06 sco1 , miscellaneous mechanical febrication , maintenance of actuator of butterfly valve , maintenance and upkeep of terminal box of motor of actuators in cw pump , maintenance re erection of butterfly valve actuator motor , revisioning and upkeep of marp dcs panel , revisioning testing of various type of switches of local control panel , maintenance revisioning upkeep and testing of 415 v power supply module , maintenance upkeep and repair of junction box of butterfly valve , servicing of mov motors actuators and limit switch assembly , checking cleaning and cable dressing mov motor , overhauling cleaning reconditioning of various size batteries , load test once in six months for various size battery of ups installed for 5x200mw , replacement of damaged switches mcb in acdb panel , cleaning painting of the wooden battery stands , maintenance of window type split type ac , gas charging of ac , rewinding of burnt fan motor
Tender For corrigendum : painting of transformer, ct and pt, m.s. earthstrips, fire buckets, fire stands and other equipments at 132 kv sub-station dumariyaganj under electricity transmission division-ii, basti