Get complete information related to latest Earth Terminal Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Earth Terminal Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Earth Terminal Tenders.
Tender For auction sale of electronic waste,furniture scrap,office electrical and telecom equipment,waste lube oil,electronics and instrumentation,ms steel,machinery,ss material,pipes,electrical and electronic items,steel,electrical electronics instrumentation and office equipment,miscellaneous scrap
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp
Tender For supply of m l for point wiring with pvc insulated unsheathed single core multi stranded copper conductor 1 5 sqmm 1100 volts grade cable frls passing through pvc casing caping including accessories , one 3 pin switch socket combination 5 amps on the same board with other switches 28 points , one 3 pin switch socket combination 5 amps independent 30 points , one bell point controlled by one push button 4 points , all as per item no 1 above but with 2 5 sqmm cable for one three pin 15 amps socket out let controlled by one switch 18 points , s f modular switch 1 module single pole one way 6 amp conforming to is 3854 and isi marked complete all as direcred 84 nos , s f modular switch 1 module single pole one way 16 amp conforming to is3854 and isi marked complete all as direcred 18 nos , s f ceiling rose with earthterminal connection 3 terminal pvc polycarbonate isolated body of size 60x50mm 26 nos , s f modular socket 6a 3 pin 2 module conforming to is 1293 2019 and isi marked complete all as direcred 58 nos , s f modular socket 6 16a 3 pin 2 module conforming to is 1293 2019 and isi marked complete all as direcred 18 nos , s f modular pvc gang box screwless of 6 module for mounting of modular switches and sockets including blank plate for blank module 8 nos , all as per item no- 8.00 above but of modular pvc gang box 4 module 22 nos , all as per item no- 8.00 above but of modular pvc gang box 3 module 38 nos , all as per item no- 37.00 above but of modular pvc gang box 2 module 5 nos , sf modular white cover plate with frame 6 module 8 nos , sf modular white cover plate with frame 4 module 22 nos , sf modular white cover plate with frame 3 module 38 nos , sf modular white cover plate with frame 2 module 5 nos , supply and fix led aluminium housing of batten fitting 20 watt 240v 4ft cdlnw comprises of aluminium extruded channel in thermally conductive material with decorative end cap , s f mcb db spn conforming to ip 43 ik 09 with acrylic double door 12 way complete with din rail neutral and earthing bar 11 nos , s f mcb spn 63 amp 10 ka 230 volt c curve type 11 nos , s f mcb single pole 20 amp 10 ka 230 volt c curve type 81 nos , s f cable pvc insulated pvc sheathed armoured frls 1100v grade 2 core 6 sqmm stranded copper conductor electric cable laid on wall roof duct complete with proper saddling , supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole mcb of capacity 20 amp, 240 volts complete all as specified and directed 26 nos , m l for pvc insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross-sectional area 50 sq mm 3.5 core 140 rm , s f vtpn db 8 way suitable for flush mounting and surface mounting with 250 a copper busbar for each phase with 2 neutral bar 2 earthbar and cable ties , s f mccb tpn 100 amp icu 16 ka 415v with magnetic release complete all as specified and directed 8 nos , s f mccb 4 pole 160 amp icu 36 ka 415v with magnetic release complete all as specified and directed 2 nos , m l for snap- on trunking system with cover angles bends and all accessories and fitting of size 50x130 mm with 2- compartment fixing on wall complete all specified and directed 90 rm , s f modular bell push switch 1 module single pole one way 6amp isi marked 4 nos , s f in replacement with modular electric bell ding dong ac 230v single pole 4 nos //bid details 2 / 28
Tender For fire work at esic haryana. - (a) supplying, installation, testing and commissioning of electric driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required :(b) horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520.(c) suitable hp squirrel cage induction motor, tefc, synchronous speed 1500 rpm, suitable for operation on 415 volts, 3 phase 50 hz, ac supply with ip 55 protection for enclosure, horizontal foot mounted typewith class-f insulation, conforming to is-325.(d) m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) suitable cement concrete foundation duly plasteredwith anti vibration pads., 2280 lpm at 70 m head, (a) supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required:(diesel driven pump)(b) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520.(c) suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulatedwith 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event offault with audio indications, painted with post office red colour etc. as required.(d) m.s fabricated, common base plate, coupling, couplingguard, foundation bolts etc. as required.(e)suitable cement concrete foundation duly plasteredand with anti vibration pads., 2280 lpm at 70 m head, (a) supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (jockey pump)(b)horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is : 1520.(c) suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase 50 hz ac supply with ip 55 class of protection for enclosure, horizontal foot mounted type with class-f insulation, conforming to is : 325.(d) m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) suitable cement concrete foundation duly plastered and with anti vibration pads., 180 lpm @70m head, fabrication, supply, insallation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earthterminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required :, incomings630a, 50ka 4 pole mccb, ics=100% icu rating digital voltmeter 0-500v with selector switch ammeter (0-630 a) with selector swtich & cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps set of copper bus bar 800amps outgoings (note : all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps)main fire pump200 amp, 50ka tpn mccb, ics=100% icu, with f
Tender For auction sale of depot ferrous scrap - scrap ms s&t released items of sort and sizes including, signal base,signal post,root drum,stracher bar,emptyvrla battery box,junction box, stop signal, shunt signal with offset, point machine body , signal pole, signal ladder, unit to aspect, route drum, rodding set, location box, gate boom, signal base, shunt signal, point d bracket, route drum, impedance bond cover, protection cover, half location frame, signal post, plunger, ladder assay, offset bracket, point machine without motor, ground connection/point rodding, ms battery box, gate meeting post, gate pedestal, gate gear box, empty cabinet, strips, plates, rods, transmission assemble, levers, pipes, ladder, fabrication angle channels, signalling electrical substation machinery parts fittings, nut bolts, signalling poles, point motor,cycle machine point plunger, route drum, p bracket, point auxiliary, clamp assly, supporting patti, fuse alarm box, power supply box, rail deflector, point jb, aftc tu jb, relay and all kind of signalling items and other miscellaneous ms gi and ci fittings with or without n/f and other attachments. nf without attachment will not be delivered. note- cutting allowed only for location boxes for easy loading at the time of delivery. location - b by 1.
Tender For providing and fixing of cable and other electric parts at various pump house. - supply of xlpe insulated power cable (conformingis-7098) 1100 volt grade/heavy duty power cable conforming to is1554-1100 volts grade, 2core/3 core/4 core isi marked with alu. stranded /solid conductor armoured 4 core uadd sor no. 14.1.8/p-79, 50 sq.mm(xlpe), 70 sq.mm(xlpe), supplying of isi marked change over switches in sheet encloser confirming to is:4064/ is:13947 (part i & iii) with side handle operated 4 pole with two earthing terminals 7.3/p-36, 100 amps. 415/500 volts.(on load ), 200 amps. 415/500 volts.( off load ), supplying of isi marked and approvedmake of moulded case circuit breaker (mccb) suitable for 3 phase, 3 pole, 50hz, 415 volts, ac supply with respective interrupting capacity (ka) at 415 volts cited against their range standard conforming to is - 88288/p-40, mccb with breaking capacity 35 ka at 415 v current rating 160 amps & adjustable : 70% - 100% thermal & 5-10 times magnetic setting 8.2.1, mccb with breaking capacity 50 ka at 415 v current rating - 400 amps & adjustable : 70% - 100% thermal & 4-10 times magnetic setting, supplying and laying of submersible flat cable isi marked 3 core copper wire of suitable size with proper clamping of approved make.10.0 sq.mm multi strand 11.5/p-165mpphed sor 1st sep. 2023
Tender For supply, erection, testing, and commissioning of electrical equipment and fire extinguishers for the kurha pdn scheme.-oil conservator with filling hole with cap and plain oil level gauge. silica gel dehydrating breather charged with silica gel. ,,oil drain valve. ,oil filter valve. ,lifting eyes/hooks. ,two earthing terminals ,diagram and rating plate. ,air vent ,explosion vent. ,100 mm dia thermometer with thermometer pocket. ,four bi directional plain roller. bucholtz relay. , resistance temp. detector. ,marshalling box. , automatic voltage regulator (avr), 16)
Tender For auction sale of depot ferrous scrap - scrap ms s&t released items of sort and sizes including, junction box, stop signal, shunt signal with offset, point machine body , signal pole, signal ladder, unit to aspect, route drum, rodding set, location box, gate boom, signal base, shunt signal, point d bracket, route drum, impedance bond cover, protection cover, half location frame, signal post, plunger, ladder assay, offset bracket, point machine without motor, ground connection/point rodding, ms battery box, gate meeting post, gate pedestal, gate gear box, empty cabinet, strips, plates, rods, transmission assemble, levers, pipes, ladder, fabrication angle channels, signalling electrical substation machinery parts fittings, nut bolts, signalling poles, point motor, point plunger, route drum, p bracket, point auxiliary, clamp assly, supporting patti, fuse alarm box, power supply box, rail deflector, point jb, aftc tu jb, relay and all kind of signalling items and other miscellaneous ms gi and ci fittings with or without n/f and other attachments. nf without attachment will not be delivered. note- cutting allowed only for location boxes for easy loading at the time of delivery. location - a by 2.