Web Analytics Made Easy - StatCounter

Earth Terminal Tenders

Get complete information related to latest Earth Terminal Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Earth Terminal Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Earth Terminal Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45738480 Due date: 21 Jul, 202621 Jul, 2026 23.32 Lacs
Tender For supply of 9u rack , 2kva ups with rack and 06 nos 18 ah battery with each set 30 min backup , 2 port io box , earthing terminal box with accessories , chemical type earthing rod with accessories , earthing pit installation job , 12 core ofc cable , lying fibre cable , 25 mm pvc casing caping , 50 mm casing caping , earthing cable 1c 4sqmm , joint closure , fibre splicing per fibre , 3 or 4 pvc pipe , flexible conduit , gi pipe 50mm , duct 40mm , danger tape , route marker , cat 6 cable , jack panel 24 port , switch socket power supply board , power cable 3 core 2.5 sqmm , power cable 3 core 4 sqmm , cat 6 cable 1 mtr , lc e2k ofc patch cable 5 mtr , lc e2k ofc patch cable 10 mtr , otb box with e2k 12 port connector , lugs ring type , 40 mm coupler , charges of i c of supplied equipment , material transportation

CTN :45729460 Due date: 13 Jul, 202613 Jul, 2026 13.69 Lacs
Tender For supply of motor pumps, starters, and other materials for drinking water works, and repair of motors, pumps, etc. as per g schedule

corporations/Associations/Others

CTN :45538364 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For corrigendum : supply of submersible pumpsets (three phase) conforming to is 8034 (v2) (q2) , submersible pump starters (motor starter controls) (q3)

Central Government/Public Sector

CTN :45680475 Due date: 15 Jul, 202615 Jul, 2026 3.52 Lacs
Tender For supply of moulded case circuit breakers (mccb) conforming to is/iec 60947 (part 2) (q2) , submersible pump starters (motor starter controls) (q3) , 63 amp onload manual changeover switch , 100 amp onload manual changeover switch , 63 amp changeover mcb type , 63 amp automatic source changeover with current limiter , 400 amp onload manual changeover switch , 100 amp automatic transfer switch , 100 amps wall mounted bus-bar chamber , 200 amps wall mounted bus-bar chamber

Central Government/Public Sector

CTN :45669536 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For repair/ replacement of dosing pumps, filter media, pump sets, motor starters and miscellaneous works at afs kumbhirgram

CTN :45689738 Due date: 06 Jul, 202606 Jul, 2026 40.0 Thousand
Tender For supply of relay swtch , main relay , earth terminal , system protection valve , bearing needle , oil seal , copper washer 18 dia , copper washer , washer , assy clutch disc pressure plate

CTN :45048307 Due date: 31 Jul, 202631 Jul, 2026 NA
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp

CTN :45691567 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For supply of submersible pump starters (motor starter controls) (q3)

Central Government/Public Sector

CTN :45376467 Due date: 09 Jul, 202609 Jul, 2026 30.00 Lacs
Tender For corrigendum : repair and comprehensive maintenance of swimming pool plant and equipments fire fighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of fire fighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit fire fighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all fire fighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressable manual call point / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and dire

State Government

CTN :45671440 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For daily labour charges with bonus once in a year for operation and upkeepment of 10 nos 6 hp submersible pump-motor sets, 2 nos 7.5 hp & 2 nos 15 hp centrifugal pump-motor sets, along with 11/0.433 kv outdoor type sub-stn, comprising of, 1 x 150 kva transformer, lt panels, starters, valves, flow meters, level indicators, entire yard lighting arrangement inside and outside of pump house complete with all other electrical accessories and ancilliaries for 24 hours a day. (4 nos. operator to be engaged)
 Loading, Please wait...

Connect us via What's Up