Get complete information related to latest Electric Supply Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electric Supply Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electric Supply Tenders.
Tender For bhoj dharti,bhoj darara,bhoj mataur, group of 3 no. of habitations annual mtc.works for water supply - supply and erection of wall mounting type, solenoid driven, motorized, electromagnetic diaphragm dozing metering pump working on three-phase 220/240 v 50 hz electricsupply with standard electronic controls, suitable for minimum dozing capacity 0 to 27 lph at 10 bar back pressure, supply and jointing three core submersible flat cables
Tender For rubber sheet, acid oil and alkali proof and capable with standing 2kv electrical supply (electrical resistant) incompressible load upto 6 tons, is 5424 black size: 3 m x 1 m x 25mm thick. [ warranty period: 30 months after the date of delivery ] ]
Tender For repair/ replacement of ac, refrigerator, water cooler geysers internal electricsupply of building submain, db, ceiling, exhaust, wall mounting, pedestal fan and its connected works in tech and residential area of irde under ge (i) rnd dehradun
Tender For corrigendum : repair / replacement and maint of lt external electricsupply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
Tender For repair/replacement of external electricsupply distribution network with other connected items at malad, marve and kandivali under ge (n) santacruz, mumbai - supply, install, testing & commissioning pedestal cubical type double door lt bus bar chamber box of suitable size factory made modular construction fabricated out of 3 mm thick crca sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements front & back side opening system including rain shed, busbar chamber should be suitable for accomodating all aluminium bus bar strips (50mm x 10mm x 04 nos) & gi strip for earth fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom part, with fixing arrangement on pcc (1:3:6) type c-2 bed block with studs, bolts, nuts & washers, danger notice board with scull suitable for 415 volts or required size to be fixed on pannel including dismantling of old bus bar panel all as specified and directed by engr-in charge.notes:-(a) aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for phases and neutral - 01 set(b) mccb 4 pole , ics=100%icu- 25 ka, 415 volts, 100 amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 nos.(c) digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable ct of appropriate ratio.-01 no make- imp/automatic electrical(ae)/ l&t / havells/ meco(d) panel indicating lamp neon/led type (red ,yellow & blue) with lamp holders - 03 nos(e) panel instrumental wiring with frls suitable size but not less than 2.5 sqmm copper wire single core - 01 job(f) necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.make of mccb & mcb: larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 400 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:- larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 160 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 16 ka 100 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 250 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb all as specified and directed by engr-in-charge make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supplying, laying,connecting, testing & commissioning lt ug pvc insulated, heavy duty, 1100 v grade electric cable with aluminium conductor of size 16 sqmm x 4 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by engineer-in-charge of following sizes:-note : earthwork excavation, dwc
Tender For corrigendum : work of supply, installation, testing and commissioning earthing for transformer center with maintenance free, ready capsule, pipe-in cage( pic) type earthing and connections to thevarious parts of transformer center using gi strip and gi nut bolts at olpad subdivision under olpad (r) division. and if it is required work to be carried out in otherscheme & other sub division under olpad (r) division.(only for 200 kva and 500 kva tc)
Tender For corrigendum : complete project management consultancy services (pmc) for provn of augmentation of electricsupply at khumbathang mil stn under amwp 2024-25 by the way of creation of 2x6.3 mva, 66by11kv lilo sub-station along with 66 kv and 11 kv lines
Tender For corrigendum : supply of providing and fixing 50 mm outer dia pipe and 25mm inner as per boq item no.3.6.1 , providing and fixing 8 swg gi earthing wire supply and laying as per boq item no.3.6.2 , providing and fixing 25 mm x 6 mm gi earthing strip supply and laying as per boq item no.3.6.3 , providing and fixing, supply and installation 150 mm wide cable tray as per boq item no.3.7.1 , providing and fixing, supply and installation 300 mm wide cable tray as per boq item no.3.7.2 , providing and fixing, wiring for lightor bell point with 2-1.5 sq.mm and earth wire of 1.5 sq.mm as per boq item no.3.8 , wiring for looped light with 2-1.5 sq.mm and earth wire of 1.5 sq.mm green both are of isi marked approved as per boq item no.3.9 , providing and fixing,wiring for fan or exahust fan or wall fan point with 2-1.5 sq.mm as per boq item no.3.10 , providing and fixing on board 6a, 5 pin socket controlled by 6a switch as per boq item no.3.11 , providing and fixing 6or16a, 5 pin socket controlled by 6a switch as per boq item no.3.12 , providing and fixing 6or16a, 5 pin socket controlled by 6a switch - single phase as per boq item no.3.13 , providing and fixing 6or16a, 5 pin socket controlled by 20a moduler sp mcb as per boq item no.3.14 , providing and fixing 2 x 1.5 sq.mm and 1 x 1.5 sqmm. copper wires with 25 mm dia frls conduit as per boq item no.3.15.1 , providing and fixing 2 x 2.5 sq.mm and 1 x 1.5 sqmm. copper wires with 25 mm dia frls conduit as per boq item no.3.15.2 , providing and fixing 2 x 4 sq.mm and 1 x 2.5 sqmm. copper wires with 25 mm dia frls conduit as per boq item no.3.15.3 , providing and fixing led rope lights as per boq item no.3.16 , providing and fixing 36w led 600mm x600mm fixture as per boq item no.3.17 , providing and fixing 18w led down lighter openor concealed as per boq item no.3.17.1 , providing and fixing 12w led down lighter openor concealed as per boq item no.3.17.2 , providing and fixing 10w led linear spot light as per boq item no.3.17.3 , providing and fixing 6worm strip light as per boq item no.3.17.4 , providing and fixing 2worm strip light as per boq item no.3.17.5 , supply installation testing and commissioning of 1200 mm 50w five star ratting as per boq item no.3.18.1 , supply installation testing and commissioning of 914 mm 60w five star ratting ceiling fan as per boq item no.3.18.2 , providing and fixing 32 mm dia. pvc conduit as per boq item no.3.19.1 , providing and fixing 25 mm dia. pvc conduit as per boq item no.3.19.2 , providing and fixing 100x50 mm pvc raceways white as per boq item no.3.19.3 , providing and fixing 50x50 mm pvc raceways white as per boq item no.3.19.4 , providing and fixing,supply, laying of cat 6 utp computer wire with conduit as per boq item no.3.20.1 , information outlets - providing and fixing,supply, installation testing and commissioning as per boq item no.3.20.2 , providing and fixing,sitc of cat6 24 port patch panel rack mount with lable as per boq item no.3.20.3 , providing and fixing,sitc of cat6 patch cord for patching at user desk 1-mtr. as per boq item no.3.20.4 , providing and fixing,sitc of cat6 patch cord for patching at user desk 2- mtr. as per boq item no.3.20.5 , providing and fixing,sitc of 6u wall mount rack for mounting devices with all required as per boq item no.3.20.6 , providing and fixing 2-module modular switchboard plates as per boq item no.3.20.7 , providing and fixing 4-module modular switchboard plates as per boq item no.3.20.8 , providing and fixing 6-module modular switchboard plates as per boq item no.3.20.9 , providing and fixing 8-module modular switchboard plates as per boq item no.3.20.10 , providing //bid details 3 / 84 and fixing 12-module modular switchboard plates as per boq item no.3.20.11 , providing and fixing,supply, installation testing and commissioning of rj 11 jack type as per boq item no.3.20.12 , providing and fixing,supply and installation of interactive panel as per boq item no.3.21 , providing and fixing,supply an
Tender For corrigendum : providing of operation and maintenance of water supply systems - voltage steplizer 4 kva,operation and maintenance of water supply systems - supply of gi plate verically,operation and maintenance of water supply systems - installation work all meterial,operation and maintenance of water supply systems - supply of pvc water tank for raw water storage 500 ltr,operation and maintenance of water supply systems - electricsupply for water cooler and starter,operation and maintenance of water supply systems - water cooler safty cover the ms jali in suport of ms angle and coverd with scp sheet and flaxe,operation and maintenance of water supply systems - water supply boaring 2 inch 80 fit with 1 hp moter for water supply,operation and maintenance of water supply systems - water cooler installation rcc work,operation and maintenance of water supply systems - portable water purification system with inbuilt water cooler ro and uv