Web Analytics Made Easy - StatCounter

Electric Cable Tenders

Get complete information related to latest Electric Cable Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electric Cable Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electric Cable Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :45738322 Due date: 15 Jul, 202615 Jul, 2026 50.00 Lacs
Tender For supply of breathing supported ventilator , mayo small tolley , smf battery , 2000va ups , electrical cable

Central Government/Public Sector

CTN :45738742 Due date: 21 Jul, 202621 Jul, 2026 NA
Tender For pvc insulated (heavy duty) electric cable 4 core x 25 sq. mm aluminium conductor conforming as per i

Central Government/Public Sector

CTN :45623027 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For corrigendum : supply of pvc insulated (heavy duty) electric cables marked to is 1554 (part 1) (v2) (q2)

Central Government/Public Sector

CTN :45713835 Due date: 18 Jul, 202618 Jul, 2026 30.00 Lacs
Tender For repair/replacement of external electric supply distribution network with other connected items at malad, marve and kandivali under ge (n) santacruz, mumbai - supply, install, testing & commissioning pedestal cubical type double door lt bus bar chamber box of suitable size factory made modular construction fabricated out of 3 mm thick crca sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements front & back side opening system including rain shed, busbar chamber should be suitable for accomodating all aluminium bus bar strips (50mm x 10mm x 04 nos) & gi strip for earth fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom part, with fixing arrangement on pcc (1:3:6) type c-2 bed block with studs, bolts, nuts & washers, danger notice board with scull suitable for 415 volts or required size to be fixed on pannel including dismantling of old bus bar panel all as specified and directed by engr-in charge.notes:-(a) aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for phases and neutral - 01 set(b) mccb 4 pole , ics=100%icu- 25 ka, 415 volts, 100 amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 nos.(c) digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable ct of appropriate ratio.-01 no make- imp/automatic electrical(ae)/ l&t / havells/ meco(d) panel indicating lamp neon/led type (red ,yellow & blue) with lamp holders - 03 nos(e) panel instrumental wiring with frls suitable size but not less than 2.5 sqmm copper wire single core - 01 job(f) necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.make of mccb & mcb: larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 400 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:- larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 160 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 16 ka 100 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 250 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb all as specified and directed by engr-in-charge make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supplying, laying,connecting, testing & commissioning lt ug pvc insulated, heavy duty, 1100 v grade electric cable with aluminium conductor of size 16 sqmm x 4 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by engineer-in-charge of following sizes:-note : earthwork excavation, dwc

Central Government/Public Sector

CTN :45719626 Due date: 18 Jul, 202618 Jul, 2026 40.00 Lacs
Tender For repair/ replacement of lt cable, lt panel and connected items in domestic area (excluding camp area), su site 1a and 1b at af stn jodhpur - excavating in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc 10 sqm on plan and getting out in soft/ loose soil complete all as specified and directed., returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil.complete all as specified and directed., removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in any type of soils.complete all as specified and directed., m&l for sand cushioning for xlpe cable with tibba sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) and punning down to 180mm to provide a required cover complete all as specified and directed by the engineer-in-charge.note:- punned thickness only shall be measured and paid., m&l for protection to cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class b bricks complete all as specified and directed by engr-in-charge., supplying and laying un-reinforced precast concrete cable cover, class lv, type i, flat, size 250mm x 150mm x 40mm confirming to is - 5820 complete all as specified and as directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm, 4 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm, 4 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 95 sqmm, 3.5 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 150 sqmm, 3.5 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable, laid in ground with aluminium conductor, 1100 volts grade, cross-sectional area 240 sqmm, 3.5 core complete all as specified and directed., taking down of lt cable any size from trech/ gi pipe/ walls/ on ground/ street light poles complete all as specified and directed., m&l for boring of holes under road, pavement, hard stansding by using manual method with 100mm hdpe pipe complete all as specified and directed by engineer-in-charge., s&f in repair mccb 400 amp, 4 pole, 415 v, 36 ka, thermal megnatic adjustable type complete all as specified and directed., s&f in repair mccb 250 amp, 4 pole, 415 v, 35 ka, thermal megnatic adjustab

Central Government And Public Sector

CTN :45615691 Due date: 02 Jul, 202602 Jul, 2026 5.65 Lacs
Tender For corrigendum : supply of repair and preventive maintenance of dg set ranchi oa - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva //bid details 2 / 35

Central Government And Public Sector

CTN :45617559 Due date: 03 Jul, 202603 Jul, 2026 5.63 Lacs
Tender For corrigendum : providing of repair maintenance of dg set hazaribag - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva

Central Government And Public Sector

CTN :45617729 Due date: 03 Jul, 202603 Jul, 2026 5.66 Lacs
Tender For corrigendum : providing of repair and maintenance of dg set under daltonganj - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva

State Government

CTN :45626450 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For corrigendum : painting of corroded electrical cable trays at pulp- electrical in tnpl unit i

State Government

CTN :45724618 Due date: 15 Jul, 202615 Jul, 2026 56.33 Lacs
Tender For procurement of instrument-signal, control & power cables for u#3&4. - procurement of instrument-signal, control & power cables for u#3&4., 12px0.5 sq.mm, overall shield cable, control cable 3cx2.5 sq mm,armoured, power cable,1.5 sqmmx3c,1.1kv,ptfe insu, flexible copper cable 18cx1.5sq mm, cable 8cx1.5 mm sq, control cable,0.5 sqmmx2p,1.1kv,ptfe ins, control cable,0.5 sqmmx8p,1.1kv,ptfe ins, 4 c x 2.5 sqmm cu armoured control cable
 Loading, Please wait...

Connect us via What's Up