Tender For supply of digital ohm meter with test voltage between 1.8 v to 2 v dc with following features 1. 41/2 digit, digital ohm meter 2. resistance range 10 ohm and 01 ohm 3. resolution 1 m ohm at 10 ohm range and 0.1 m ohm at 01 ohm range 4. +0.05% accuracy 5. 03 meters test leads with crocodile clips , make :- teams , model no dlrm-21 or equivalent. note : voltage must be between 1.8 v and 2 v dc while checking the resistance. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of instruments/other items (part-6 of 6) - expiratory valve 23bc, cdsco, euce 6993, whogmp, iso134852016, iso90012567, 1 no., 1754, silicone disc mebrane for "l" valve, cdsco, euce 6993, whogmp, iso134852016, iso90012571, 1 no., 1758, raos two stage air regulator 0400kg and 04kg, cdsco, euce 6993, whogmp, iso134852016, iso90012575, 1 no., 1762, video laryngoscope set with polycarbonate blade size 1, 2, 3, 4 (2 nos. each size) all in a carrying case, cdsco, euce 6993, whogmp, iso134852016, iso90012582, 1 no., 1766, polycarbonate curved macintosh blade size 4, cdsco, euce 6993, whogmp, iso134852016, iso90012586, 1 no., 1770, metal reusavke macintosh blade size 3, cdsco, euce 6993, whogmp, iso134852016, iso90012591, 1 no., 1774, metal reusavke miller blade size 0, cdsco, euce 6993, whogmp, iso134852016, iso90012595, 1 no., 1778, ambu auraonce mask size 2, cdsco, euce 6993, whogmp, iso134852016, iso90012601, 1 no., 1782, ambu auraonce mask size 5, cdsco, euce 6993, whogmp, iso134852016, iso90012605, 1 no., 1786, specifications of image processor (should be cdsco, iso 13485 approved) (principal company should have their own service center running with certified trained engineers without any thirdparty arrangements in india.) 1 the image processor should be compatible of providing output of 1920*1090p resolution full hd. 2 the image processor should have compatible of camera head for existing urology procedure rigid scopes. 3 the image processor should have in built led light source in same box. the inbuilt led light source should have life hours of at least 44,000 + hours of life. 4 the image processor should have digital outputs of dvi, sdi, vga and compostie/bnc. 5 the image processor should have compatible separate recordings slots of flexible scope and rigid camera head in full hd resolution. 6 the image processor should have separate settings for flexible scope and rigid which should be clarified at user interface. 7 the compatible camera head to image processor should very handy light weight of 250 gms. 8 the image processor can be used to control the led lights of scope accordingly to use as per surgeon preference and vision comfort., 1 no., 1790, 365 micron reusable 3 meters, flexible fiber (laser machine should be cdso, bis, iso 13458 ce approved), 1 no., 1794, 1000 micron reusable 3 meters, flexible fiber (laser machine should be cdso, bis, iso 13458 ce approved), 1 no., 1798, single pedal spill proof foot switch (laser machine should be cdso, bis, iso 13458 ce approved), 1 no.
Tender For providing of repair and overhauling service - rate contract for repairs and calibration of flow meters control system analogue digital installed onboard in vessels; any other suitable brand; no; buyer premises
Tender For corrigendum : battery charging and discharging panel: supply and commissioning of digital signal processing (dsp) controlled igbt based ac to dc rectification (converter) with active power factor correction with finecontrol on voltage regulation, ripple, thd and improved efficiency with re-generative feature suitable to provide float charging and boost charging of ni-cd batteries of 199 ah/110 v capacity & lead acid batteries of 75 ah/110 v capacity as per specification no. c/e/els/ers/spec/06 attached. all meters and gauges to have valid calibration certificate from nabl approved lab. [ warranty period: 30 months after the date of delivery ]
Tender For battery charging and discharging panel: supply and commissioning of digital signal processing (dsp) controlled igbt based ac to dc rectification (converter) with active power factor correction with finecontrol on voltage regulation, ripple, thd and improved efficiency with re-generative feature suitable to provide float charging and boost charging of ni-cd batteries of 199 ah/110 v capacity & lead acid batteries of 75 ah/110 v capacity as per specification no. c/e/els/ers/spec/06 attached. all meters and gauges to have valid calibration certificate from nabl approved lab. [ warranty period: 30 months after the date of delivery] ]
Tender For corrigendum : supply of digital ph meter , crash cart , digital spirometer , ultra- sonogram obs and gyne , bipolar cautery , icu ventilator neonatal and paediatrics , multipara monitor with wall mounten adjustable stands without centeral monitoring station , multipara monitor 3 para meters , multipara monitor 5 para meters , oxygen cylinder trolley medium , digital microscope , urine analyzer , kocher forceps , bed side screen , class ii b2 bio safety cabinet , oxygen cylinder trolley small , defibrillator (q2)
Tender For supply, installation and commissioning of 0.2s class advanced digital energy meters for vital feeders at sy/ty and powerhouse locations at stage-iii kgsc