Get complete information related to latest Electrical Actuator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electrical Actuator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electrical Actuator Tenders.
Tender For work of repairing/servicing of boiler & turbine side rotork/limitorque/auma make electricalactuators, during coh of unit 4,250 mw at paras tps.
Tender For soft starter for 3- phase induction motor (90 kw) 3-phase, 415vac, 50 hz ac for nf combust ion & id fan motor with following specification:-(i) adjustments:initial start voltage,start ramp time, soft st op ramptime, motor flccurrent ramp,current limit, motor trip class. soft stoptime, excess starttime, pha se sequence protection, auxiliary relay protection. (ii) indications: no control power, starter ready, starter tripped, motor not running, motor running at full speed, motor starting/ stopping. (iii) alarms: power circuit , supply frequency, communication problem, excess start time, motor overload, motor thermistor, phase i mbalance, phase sequence.(iv) digital input start, stop, motor thermistor probe. (v) digital output: main c ontactor relay, programmable relay. (vi) local reset. (vii) control power supply: 110 vac (viii)power supp ly 415 vac, with installation, testing, commissioning, proper fitment & interfacing with existing system.m ake-l & t, crompton greaves, hitachi, abb, siemens, schneider electric, nord drive system, allen bradley or similar. [ warranty period: 12 months after the date of delivery ]
Tender For e-tender (2nd call) for procurement of laboratory instruments, equipment, appliances for the college of veterinary sciences and ah, rk nagar under the nec funded project for the year 2025-2026 - biosafety cabinetclassii, a 2 with accessories and power back up (bacteriology)-- the biological safety cabinet should be of class ii, type a2 designed in compliance with international standards the biological safety cabinet quoted instrument model must have international standards test likensf, tuv nord, en 12469 certification. certificate copy must be provided along with the technical bid. working area should be around 4foot. it should have exterior dimension w x h x d of 1300x 1568 x 800 and interior dimension wxhxdof 1200x 780x 630 it should have 1 piece grade 304 stainless steel or thermos scientific smart coat interior itshouldhavefeatureforpersonalprotection,sample protection, cross contamination protection and environmental protection. it must utilize brushless dc motor technology which uses significantly less energy with less heat emission provision compared to traditional ac motor technology to ensure lower levels of energy consumption. it should have 10 sloped front for exceptional comfort and ergonomics thesystemshouldbedesignedwithdualmotor. the motor must automatically adjust or control fan speed in real time to maintain constant airflow during filter loading or temporary obstruction. air flow direction: vertical laminar flow & air intake across front opening and 70% recirculation. filter: high performance particle air filter h14(hepa en1822), filtering efficiency 99.995% mpps or better. energy saving mode when cabinet not in use with maintaining sterility. continuous airflow helps to maintaina sterile environment, evenwhen the cabinet is not in use. thesystemshouldhaveindependentsensorstodetect pressure changes across the exhaust and down flow plenum/ air velocity and should indicate alarm signal when a 20-30% change in inflow/ exhaust or down flow occurs. control panel and performance monitor displays inflow/ down flow velocities, hours of use etc. to verify proper cabinet operation. frontglasswindowshouldbeeasilyloweredfor thorough smart cleaning of inner surfaces and designed to protect users by maintaining inflow, even when the window is lowered. the uv light must be quoted which should be programmable from 30 min to 24 hrs. in minimum 30 minutes increment to shut off automatically. the settings must allow the user to program the timer. the cabinet noise level must be less than 63 db(a) as measured in a sound proof room to promote more comfortable and safer working habitsof the user a per nsf/ ansi 49. the controller must be located on a slanted frontpanel so it is easy to see from a seated working position in front of the cabinet. control panel should be a large digital color touch screen display with health monitoring system, valuable safety and performance data with constant read-out of downflow/ inflow velocities and hours of operation in real-time, number of hours of use on the hepa filters. the front window sash must be angled 10 sloped front for operator comfort. two pieces of removable and autoclavable stainless steel arm rest should be provided for operator s comfort without disturbing the air flow. the system must have audio visual alarms to indicate when inflow is restricted and as well as whether front window is in correct position or not. theworkareashouldbeilluminatedwithswitchable fluorescent lamp of lighting power >120 fc or higher. suitable height floor stand without casters should be provided. in built access ports, 2 nos. (1 on each side) shouldbe available. it has single piece stainless steel work tray for easy cleaning and decontamination. warranty:minimum3year. electrical supply available: 230v a.c, single phase, 50 hz. bidder should provide printed brochure of the quoted model and details specification should be available in the manufacture website. customized model would not be accepted wi
Tender For corrigendum : supply of actuators - ah inlet damper rh as per sl-no- 05 of datasheet ref-dampr-act data-1555d , l155515757701020 - electricalactuator for pa ah inlet damper rh as per sl-no- 06 of datasheet ref-dampr-act data-1555d , l155515757701021 -electricalactuator for sa ah outlet damper rh as per sl-no- 07 of datasheet ref- dampr-act data-1555d , l155515757701022 - l155515757701023 -electricalactuator for pa ah outlet damper lh -rh as per sl-no- 08 - 09 of datasheet ref-dampr-act data-1555d -lh 1 nos - rh 1 nos , l1555157f7701001 - l1555157f7701002 - electricalactuator for fgd inlet gate lh - rh as per sl-no- 01 - 02 of datasheet ref-gate-act data- 1555-57n60g -lh 1 nos - rh 1 nos , l1555157f7701003 - electricalactuator for fgd outlet gate as per sl- no- 01 of datasheet ref-gate-act data-1532g57c70 rev00 , l1555157s7701001 - l1555157s7701002 - electricalactuator for scr bypass gate lh - rh as per sl-no- 15 - 16 of datasheet ref-gate-act data- 1555g -lh 2 nos - rh 2 nos , l155515757702001 - elec actuator for methanol tap off gate as per sl-no-01 of datasheet ref-gate-act data-1532g57cx0 , l156115757701001 - l156115757701002 - gate -fd fan o-l as per sl- no- 1 - 02 of ref-gate-act data-1561g- rev0 , l156115757701003 - l156115757701004 - gate - esp i-l as per sl- no- 3 - 04 of ref-gate-act data- 1561g- rev0 , l156115757701005 - l156115757701006 - gate -esp o-l as per sl- no- 3 - 04 of ref-gate-act data-1561g- rev0 , l156115757701007 - l156115757701008 -gate -gas ah o-l as per sl- no- 7 - 08 ref-gate-act data-1561g , l156115757701009 - l156115757701010 - gate -pa fan o-l as per sl- no- 9 - 10 ref-gate-act data-1561g , l156115757701011 - l156115757701012 -gate -id fan i-l as per sl- no- 11 - 12 ref-gate-act data-1561g- rev0 , l156115757701013 - l156115757701014 - gate -id fan o-l as per sl- no- 13 - 14 ref-gate-act data-1561g- rev0 , l156115757701015 - l156115757701016 - damper -sa scaph i-l as per sl- no- 1 - 02 ofref-dampr-act data- 1561d- rev0 , l156115757701017 - l156115757701018 - damper -sa scaph o-l as per sl- no- 3 - 04 of ref- dampr-act data-1561d- rev0 , l156115757701019 - damper -sa ah i-l as per sl- no- 5 of ref-dampr-act data-1561d- rev0 , l156115757701020- damper -pa ah i- l as per sl- no- 6 of ref-dampr-act data-1561d- rev0 , l156115757701021- damper -sa ah o-l as per sl- no- 7 of ref-dampr-act data-1561d- rev0 , l156115757701022 - l156115757701023 - damper -pa ah o-l as per sl- no- 8 - 09 of ref-dampr-act data-1561d- rev0 , l1561157f7701001 - l1561157f7701002 - gate - fgd i-l as per sl- no- 15 - 16 of ref-gate-act data- 1561-57n60g- rev0 , l1561157f7701003- gate -fgd o-l as per sl- no- 1 of ref-gate-act data-1561g57c70- rev0 , l1561157s7701001 - l1561157s7701002 -gate - scr bypass as per sl- no- 15 - 16 of ref-gate-act data-1561g- rev0 , l1577157577010001 - l1577157577010002 -electricalactuator for fd fan outlet gate lh - rh as per sl.no. 01 - 02 of datasheet ref-gate-act data-1577g , l1577157577010003 - l1577157577010004 -electricalactuator for esp inlet gate lh - rh as per sl.no. 03 - 04 of datasheet ref-gate-act data-1577g , l1577157577010005 - l1577157577010006 -electricalactuator for esp outlet gate lh - rh as per sl.no. 05 - 06 of datasheet ref-gate-act data-1577g , l1577157577010007 - l1577157577010008 -electricalactuator for for gas //bid details 2 / 66 l1577157577010008 -electricalactuator for for gas ah outlet gate lh - rh as per sl.no. 07 - 08 of datasheet ref-gate-act data-1577g , l1577157577010009 - l1577157577010010 -electricalactuator for for pa fan outlet gate lh - rh as per sl.no. 09 - 10 of datasheet ref-gate-act data-1577g , l1577157577010011 - l1577157577010012 -electricalactuator for for id fan inlet gate gate lh - rh as per sl.no. 11 - 12 of datasheet ref-gate-act data- 1577g , l1577157577010013 - l1577157577010014 - electricalactuator for for id fan outlet gate lh - rh as per sl.no. 13 - 14 of datasheet ref-gate-act data-1577g , l1577157577010015 - l1577157577010016 - elect
Tender For supply of 30157 - "suction machine specifications: 1.motor and suction power: motor type: high- performance piston or diaphragm motor, . suction power: more than -550 mmhg to -700 mmhg wit h adjustable pressure settings, . flow rate: ranges between 15 to 30 liters per minute (l/min) . 2. coll ection canisters: material: transparent polycarbonate or autoclavable plastic. volume capacity: 2 liter s per can. overflow protection: built-in overflow shutoff valves to prevent fluid from entering the pump . lid and sealing mechanism: airtight seals on the canister lids to prevent leaks and maintain suction. 3. tubing: material: medical-grade pvc or silicone, clear and flexible for visibility and easy handling. le ngth: 1 to 2 meters . tubing diameter: 7 mm to 10 mm (inner diameter) to maintain optimal fluid flow. 4. filtration: bacterial filter: high-efficiency bacterial filter filter placement: located between the sucti on tubing and the pump for optimal protection. 5. controls: pressure adjustment dial: allows for precis e control over suction power. on/off switch: to show power status. 6. portability: size and weight: aro und 5 to 10 kg. mobility features: should equipped with wheels or handle 7. power source: electrical: standard models operate on 110-240v ac for worldwide compatibility. 8. noise level: < 45 db 9. sterilization: autoclavable components: collection canisters, tubing, and filter elements should b e sterilizable to ensure hygiene. 10. additional features: overflow protection system: prevents damag e to the machine if the canister overflows. vacuum gauge: allows for real-time monitoring of suction p ressure. emergency vent: quick-release vent for immediate pressure release if needed.". ]
Tender For corrigendum : supply of various electrical components (cable glands, lugs, tb and fuses) for electricalactuators installed in abvtps, cspgcl, janjgir-champa.
Tender For corrigendum : supply of supply of vfd 1200kw/690v/3ph/ip42 supply of vfd 1200kw, 690v, 3ph, ip42 ingress protection panel c , supply of ac induction motor supply of ac induction motor 1200kw, 3ph, 690v, water or oil cooled, co , supply of plc panel and scada supply of plc panel and scada for drive & motor control, system contro , nstallation, commissioning & testing of vfd, motor, plc, scada as per edt-2149